US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 15474-2010: Classification on instrumentation and control function important to safety for nuclear power plants Status: Valid GB/T 15474: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 15474-2010 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Classification on instrumentation and control function important to safety for nuclear power plants
| Valid |
GB/T 15474-2010
|
| GB/T 15474-1995 | English | 719 |
Add to Cart
|
5 days [Need to translate]
|
Safety classification of instrumentation and control systems and their electrical equipment of nuclear power plants
| Obsolete |
GB/T 15474-1995
|
PDF similar to GB/T 15474-2010
Basic data | Standard ID | GB/T 15474-2010 (GB/T15474-2010) | | Description (Translated English) | Classification on instrumentation and control function important to safety for nuclear power plants | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F82 | | Classification of International Standard | 27.120 | | Word Count Estimation | 19,150 | | Date of Issue | 2010-11-10 | | Date of Implementation | 2011-05-01 | | Older Standard (superseded by this standard) | GB/T 15474-1995; GB/T 15475-1995 | | Quoted Standard | GB/T 12727; GB/T 13625; GB/T 13626; GB/T 13630; EJ/T 1143; HAF 003; HAD 102/14 | | Adopted Standard | IEC 61226-2005, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 8 of 2010 (total 163) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the nuclear power plant instrumentation and control important to safety functions and the implementation of the function classification systems and equipment, and to determine the function of each category, reliability, performance, environmental durability and seismic performance and other aspects of the technical requirements and quality assurance requirements for all new nuclear power plant instrumentation and control systems important to safety (including safety systems and safety-related instrumentation and control system) design. |
GB/T 15474-2010: Classification on instrumentation and control function important to safety for nuclear power plants ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Classification on instrumentation and control function important to safety for nuclear power plants
ICS 27.120
F82
National Standards of People's Republic of China
Replacing GB/T 15474-1995, GB/T 15475-1995
Nuclear power plant safety instrumentation and control important functional classification
(IEC 61226.2005, Nuclearpowerplants-
Classificationofinstrumentationandcontrolfunctions, MOD)
Issued on. 2010-11-10
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 classification principles and methods 2
5 Function Category Description 2
6 Category 4 program
5 7 all kinds of other technical requirements
Appendix A (informative) Applicable standards and technical requirements for different categories of function 10
Annex B (informative) This standard reg number and IEC 61226.2005 reg control number 12
Annex C (informative) nuclear power plant instrumentation and control important to safety and the typical functions of the system 13
Foreword
This revised standard adopts IEC 61226-2005 "nuclear power plant instrumentation and control systems important to safety instrumentation and control the functional classification" (in English), the main difference
as follows.
--- Remove IEC 61226-2005 foreword, introduction of revised IEC 61226-2005.
--- Revised Chapter 1, "scope" of the content.
--- Delete Chapter 3, "Terms and Definitions", "Common Cause Failures 3.2, 3.5 Diversity 3.6 device features 3.7, 3.9 ergonomics,
Plant states 3.11, 3.12 performance, redundancy 3.14, 3.15 Security Group, a single fault 3.18, 3.19 system, type test 3.20
Inspection ", these terms are well known in the nuclear power industry, we need to redefine this standard. Add" instrumentation and control function "and the term
definition.
--- Delete Chapter 4, "Acronyms."
--- 5.1 ~ 5.3.1 content according to the actual situation of China's nuclear power projects integrated into Chapter 4, "classification principles and methods."
--- The contents 7.1 Table 1 are attached as Appendix A.
Appendix B lists the number of this standard and IEC 61226-2005 reg reg control list numbered.
This standard replaces GB/T 15474-1995 "nuclear power plant instrumentation and control systems and security equipment power rating" and
GB/T 15475-1995 "nuclear power plant instrumentation and control systems and power supply equipment quality assurance rating."
This standard GB/T 15474-1995-based, integrated content GB/T 15475-1995 be revised.
This standard compared with GB/T 15474-1995, in addition to editorial changes outside the main technical changes are as follows.
--- Modify the standard name;
--- Modify the scope of application;
--- Added "Chapter 3 Terms and definitions";
--- The instrumentation and control systems and their electrical equipment safety classification is amended as nuclear power plant instrumentation and control systems important to safety according to their function
The importance of security classification, and gives the principles and methods of classification, functional class description, classification procedures and technical requirements.
This standard Annex A, Annex B, Annex C is informative appendix.
The standard proposed by China National Nuclear Corporation.
This standard by the National Standardization Technical Committee on nuclear instrumentation.
This standard was drafted. Institute of Nuclear Industry Standardization.
Drafters of this standard. Choi Jung north, Zhang Jian Qing, Wang Gensheng.
This standard replaces the standards previously issued as follows.
--- GB/T 15474-1995;
--- GB/T 15475-1995.
Introduction
Nuclear power plant safety is based on the functions of the various categories of security settings can be guaranteed. Different functions of systems, equipment design, construction and operation
Process to comply with different standards and norms. To this end, International Atomic Energy Agency (IAEA) for nuclear power plant safety instrumentation and control systems important
EC (including computer software) should be classified on its safety significance, and determine the appropriate technical requirements and quality requirements, the instrument and control system
System design, construction and operation of its security importance consistent.
GB/T 15474-1995 "nuclear power plant instrumentation and control systems and their electrical equipment safety classification" is a nuclear power plant instrumentation and control systems
According to the importance of safety equipment into the security level, safety and non-safety related equipment important equipment for each level provides assurance function, can
By guarantees, performance guarantees, the ability to ensure resistance to environmental and quality assurance requirements. GB/T 15474-1995 Reference IEC 61226.
1993 "Nuclear power plant safety instrumentation and control important functional class" (in English) and RCC-P. 1984 "900MW PWR nuclear power plant system design
Design and construction rules "establishment, but the IEC and RCC-P for instrumentation and control systems, the concept of security classification of different equipment, different classification methods, so
GB/T 15474-1995 There are many problems in the course.
In recent years, IEC standard architecture for nuclear power plant instrumentation and control systems important to safety made adjustments, and formed a IEC 61513 "Nuclear
Power plant instrumentation and control systems important to safety - General requirements "(in English) for the first level, IEC 61226" Nuclear power plant instrumentation and control systems important to safety tester
Control functional classification "(in English) as the second level, the relevant equipment standards for the third-level nuclear power plant engineering standards. IEC 61226.
2005 follows the IAEA Safety Standards NS-R-1 proposed nuclear power plant safety design requirements, and extends the Safety Guide NS-G-1.3 on real
The importance of security classification policy applied function, the nuclear power plant instrumentation and control systems important to safety (including safety systems and safety related systems) power
Can be classified according to their safety significance (A Class A, B, or C), and the provisions of the various types of functions and features, performance, reliability, resistance equipment
Relevant technical requirements and quality requirements for environmental capacity.
This revised standard adopts IEC 61226.2005 "Nuclear power plant instrumentation and control systems important to safety instrumentation and control the functional classification" (in English), not only correct
N GB/T 15474-1995 IEC 61226 for the deviation, but also with reference to other existing standards IEC series of standards revision phase
coordination.
Nuclear power plant safety instrumentation and control important functional classification
1 Scope
This standard specifies the classification of the functions of systems and equipment important to safety instrumentation and control functions and the implementation of nuclear power plants, and identified
Technical requirements for each category and quality in functionality, reliability, performance, durability and environmental aspects of the seismic performance assurance requirements.
This standard applies to all instrumentation and control systems important to safety, the new nuclear power plant (including safety systems and safety-related instrumentation and control systems)
design.
Note. There is a reference power plant has been carried out and the design of new nuclear power plants according to the actual situation, the implementation of this standard may be conditionally.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 12727 Nuclear power plant safety systems of electrical equipment qualification (GB/T 12727-2002, IEC 60780.1998, MOD)
GB/T 13625 Nuclear power plant safety systems of electrical equipment seismic qualification (GB 13625-1992, eqvIEC 60980. 1988)
GB/T 13626 single failure criterion is applied to nuclear power plant safety systems (GB/T 13626-2008, IEEE379-2000,
MOD)
GB/T 13630 nuclear power plant control room design (GB/T 13630-1992, eqvIEC 60964)
EJ/T 1143 nuclear power plant control room design features analysis and distribution (IEC 61839, MOD)
HAF003 quality assurance nuclear power plant safety requirements
HAD102/14 nuclear power plant safety related instrumentation and control systems
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
Anticipated operational occurrences anticipatedoperationaloccurrences
In the nuclear power plant operating lifetime is expected to occur once or several times during the operation of the various deviations from normal operation; because of the design has been adopted
Take appropriate measures, such events important to safety Buzhi Yu cause serious damage to the items, it will not lead to accident conditions.
3.2
Design basis accidents designbasisaccident; DBA
Nuclear power plant design criteria determined by taking those accident conditions targeted measures in the design.
3.3
Design basis events designbasisevent; DBE
To determine the equipment, systems and structures, performance requirements, and hypothetical abnormal events used in the design.
3.4
Instrumentation and control functions I
Control of the process to determine the implementation, operation and/or monitoring.
3.5
Functionality functionality
Predetermined input information into output attribute information.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15474-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 15474-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15474-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15474-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15474-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15474-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|