US$499.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 15092.2-2023: Switches for appliances - Part 2-1: Particular requirements for cord switches Status: Valid GB/T 15092.2: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 15092.2-2023 | English | 499 |
Add to Cart
|
5 days [Need to translate]
|
Switches for appliances - Part 2-1: Particular requirements for cord switches
| Valid |
GB/T 15092.2-2023
|
GB 15092.2-2014 | English | 799 |
Add to Cart
|
4 days [Need to translate]
|
[GB/T 15092.2-2014] Switches for appliances -- Part 2: Particular requirements for cord switches
| Obsolete |
GB 15092.2-2014
|
GB 15092.2-1994 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Switches for appliances. Part 2: Particular requirements for cord switches
| Obsolete |
GB 15092.2-1994
|
PDF similar to GB/T 15092.2-2023
Basic data Standard ID | GB/T 15092.2-2023 (GB/T15092.2-2023) | Description (Translated English) | Switches for appliances - Part 2-1: Particular requirements for cord switches | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K64 | Classification of International Standard | 29.120.40 | Word Count Estimation | 26,262 | Date of Issue | 2023-08-06 | Date of Implementation | 2024-03-01 | Older Standard (superseded by this standard) | GB/T 15092.2-2014 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 15092.2-2023: Switches for appliances - Part 2-1: Particular requirements for cord switches---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.120.40
CCSK64
National Standards of People's Republic of China
Replace GB/T 15092.2-2014
appliance switch
Part 2-1.Special requirements for flexible cord switches
(IEC 61058-2-1.2018,MOD)
Published on 2023-08-06
2024-03-01 Implementation
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
Introduction V
1 Scope 1
2 Normative reference documents 1
3 Terms and Definitions 2
4 General requirements 3
5 General precautions for testing 3
6 Rating 3
7 Category 3
8 Logo and Documentation 4
9 Protection against electric shock 4
10 Grounding device 4
11 Terminals and Headers 5
12 Structure 5
13 institutions 9
14 Protection against solid foreign objects, water and moisture9
15 Insulation resistance and dielectric strength9
16 Fever 9
17 Durability 10
18 Mechanical strength 10
19 Screws, current-carrying parts and couplings10
20 Clearances, creepage distances, solid insulation and coatings of rigid printed circuit board components11
21 Fire hazard11
22 Anti-rust 11
23 Abnormal operation and fault conditions of switches 11
24 Switching components 11
25 Electromagnetic compatibility (EMC) requirements11
Appendix 16
Figure 101 Pull test equipment for cord fixing device 12
Figure 102 Bending test equipment 13
Figure 103 Rolling barrel 14
Figure 104 Torque test equipment for cord fixtures 15
Figure 105 Example of insulation structure for single-pole flexible wire switch 15
Table 3 Switch data and group load 4
Table 4 Resistive current carried by terminals and corresponding cross-sectional area of connected unprepared conductors5
Table 101 Rated current of resistive loads and corresponding types of cords 6
Table 102 Conductor specifications 8
Table 103 Torque values for insulating material screws 11
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents"
Drafting.
This document is Part 2-1 of GB/T 15092 "Appliance Switches". GB/T 15092 has issued the following parts.
---Appliance switches Part 1.General requirements (GB/T 15092.1-2020);
---Appliance switches Part 1-1.Mechanical switch requirements (GB/T 15092.101-2020);
---Appliance switches Part 1-2.Electronic switch requirements (GB/T 15092.102-2020);
---Appliance switches Part 2-1.Special requirements for soft cord switches (GB/T 15092.2-2014);
---Appliance switches Part 2-5.Special requirements for conversion selectors (GB/T 15092.3-2014);
---Appliance switches Part 2-4.Special requirements for independently installed switches (GB/T 15092.4-2006);
---Appliance switches Part 2-6.Special requirements for switches for hand-held and portable power tools and garden machines (GB/T 15092.5-
2021).
This document replaces GB/T 15092.2-2014 "Appliance Switches Part 2.Special Requirements for Soft Wire Switches" and is the same as GB/T 15092.2-
Compared with.2014, in addition to structural adjustments and editorial changes, the main technical changes are as follows.
a) Added 12.3.106b) as “As long as the insulation layer of the flexible wire is not cut or obviously damaged, flexible deformation is allowed” [see
12.3.106b)];
b) The outer diameter range in Table 101 is deleted (see the.2014 version of Table 101);
c) Change the title of Chapter 24 "Electronic Switching Components" to "Switching Components" (see Chapter 24, Chapter 24 of the.2014 edition);
d) Change the title of Figure 104 "Torque test equipment for cord fixtures" to "Torque test equipment for cord fixtures" (see
Figure 104,.2014 version of Figure 104).
This document is modified to adopt IEC 61058-2-1.2018 "Appliance switches Part 2-1.Special requirements for flexible cord switches".
The technical differences between this document and IEC 61058-2-1.2018 and their reasons are as follows.
---Replaced IEC 60335-2-17 (see Chapter 8 and Chapter 12) with GB 4706.8 for the convenience of users;
---Replaced IEC 60245 (all parts) with the adopted GB/T 5013 (all parts) (see Chapter 2, Chapter 12) to comply with
my country’s technical situation;
---Replaced IEC 60227-5 (see Chapter 12) with GB/T 5023.5 for the convenience of users;
---Replaced IEC 60227 (all parts) with the adopted GB/T 5023 (all parts) (see Chapter 12) to comply with my country's technology
Condition;
---Replaced IEC 61058-1.2016 with GB/T 15092.1-2020, which revised the procurement standard, to adapt to my country's technical conditions;
---Replaced IEC 61058-1-2.2016 (see Chapter 10) with the revised procurement standard GB/T 15092.102-2020 to adapt to our country
technical conditions;
---Replaced IEC 61032 (see Chapter 9) with GB/T 16842 for the convenience of users;
---14.3 corresponding to IEC 61058-2-1.2018."Moisture treatment is carried out in a humidity box, and the relative humidity of the air in the box is
Between 91% and 95%. In all places where the specimens are placed, the air temperature is maintained at any suitable temperature between 20°C and 30°C.
Value (t)”, considering that some areas in my country have a humid tropical climate, and my country’s electrical and electronic products all use (40±2)℃ for moisture-proofing
Test, so this document stipulates. "The moisture treatment is carried out in a humidity box, and the relative humidity of the air in the box is between 91% and 95%.
In all places where specimens are placed, the air temperature is maintained at any suitable temperature value (t) between 30°C and 40°C (see 14.3).
The following editorial changes have been made to this document.
---Change the clerical error in Chapter 25 "Except for the following content, IEC 61058-1.2018 this chapter applies" to "GB/T 15092.1-
Chapter 25 of 2020 applies” (see Chapter 25).
Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents.
This document is proposed by the China Electrical Equipment Industry Association.
This document is under the jurisdiction of the National Technical Committee for Standardization of Electrical Accessories (SAC/TC67).
This document was drafted by. Shanghai Electric Tool Research Institute (Group) Co., Ltd., Suzhou Novo Electric Co., Ltd., Zhongzhi Shangdong (Shanghai)
Hai) Testing Technology Co., Ltd., Suzhou Huazhijie Telecommunications Co., Ltd., Southeast Electronics Co., Ltd., Fade Electric Co., Ltd., Chang
Zhou Yunjie Electric Co., Ltd., China Quality Certification Center, Zhejiang Zhongxun Electronics Co., Ltd., Zhejiang Jiaben Electronics Co., Ltd., Zhejiang Heling Electric Co., Ltd.
Gas Co., Ltd., Wenzhou Gangyuan Electronics Co., Ltd., Zhongshan Yonglian Electrical Products Co., Ltd., Defeng Dianchuang Technology Co., Ltd., Yueqing
Huiyang Mechanical and Electrical Co., Ltd., Ruian Huatong Appliance Switch Co., Ltd.
The main drafters of this document. Chen Ping, Zhang Weichang, Yang Xiaolong, Feng Rengang, Lu Yazhou, Qiu Wenkui, Zhou Jinlong, Chu Yunyue, Wu Lan, Zheng Jianzhong,
Ni Shenglong, Shen Dingli, Sheng Liming, Feng Jiawen, Yang Bin, Wu Shiqing, Lu Jianfeng, Yan Qunhua, Qu Hailiang, Xu Yunan.
The previous versions of this document and the documents it replaces are as follows.
---First published as GB 15092.2-1994 in.1994, first revised as GB/T 15092.2-2014 in.2014;
---This is the second revision.
Introduction
GB/T 15092 "Appliance Switches" is a basic standard for product structure safety, performance testing, and material confirmation in the field of appliance switches. It is applicable to
Appliance switches that connect or control household or similar electrical appliances and other equipment. Also applicable to appliance switches that provide additional control functions.
Off, applicable to both circuits required to evaluate appliance switches and appliance switch functions.
GB/T 15092 is intended to consist of the following parts.
---Part 1.General requirements. The purpose is to establish general basic requirements applicable to appliance switches;
---Part 1-1.Mechanical switch requirements. The purpose is to establish general requirements applicable to mechanical switches in appliance switches;
---Appliance switches Part 1-2.Electronic switch requirements (GB/T 15092.102-2020). The purpose is to establish the suitability for appliances
General requirements for electronic switches in switches;
---Appliance switches Part 2-1.Special requirements for soft cord switches (GB/T 15092.2-2014). The purpose is to establish the applicable
Special requirements for cord switches in appliance switches;
---Part 2-4.Special requirements for independently installed switches. The purpose is to establish the characteristics of switches suitable for independent installation in appliance switches.
special requirements;
---Part 2-5.Special requirements for conversion selectors. The purpose is to establish special features suitable for use with change-over selectors in appliance switches.
Require;
---Part 2-6.Special requirements for switches for hand-held and portable power tools and garden machines. The purpose is to establish the suitability for appliances
Special requirements for switches for hand-held and portable power tools and garden machines.
appliance switch
Part 2-1.Special requirements for flexible cord switches
1 Scope
Except for the following content, Chapter 1 of GB/T 15092.1-2020 applies.
Increase.
This document applies to electrical appliances and other electrical appliances with a rated voltage not higher than 250V and a rated current not higher than 16A for household or similar purposes.
A mechanical or electronic soft-wire switch used in equipment that is driven or controlled by hands, feet or other human body movements.
In this document the word "appliance" means "appliance or equipment".
This type of switch must be operated by a person through an actuator or by an excitation sensor device. The actuator or sensor device is physically attached or
Electrically integrated with the switch or configured separately, it may also include signal transmission between the actuator or sensor and the switch, such as electrical,
Optical, acoustic or temperature signal transmission.
Switches with additional control functions subject to the control of the switch function are within the scope of this document.
This document also covers indirectly driven switches, where the operation of the actuator or sensor device is by a remote control, part of the appliance (e.g.
door) to reach.
Note 1.Electronic switches can be combined with mechanical switches that provide full disconnection or micro-disconnection.
Note 2.Electronic switches without mechanical switches in the power circuit only provide electronic disconnection, therefore, the circuit on the load side is always considered live.
Note 3.For switches used in tropical climates, additional requirements may apply.
Note 4.Note that appliance standards may contain additional requirements or replacement requirements for switches.
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document.
Except for the following content, Chapter 2 of GB/T 15092.1-2020 applies.
Increase.
GB 4706.8 Special requirements for safety electric blankets, electric heating pads and similar flexible heating appliances for household and similar electrical appliances
(GB 4706.8-2008,IEC 60335-2-17.2006,IDT)
GB/T 5013 (all parts) Rubber insulated cables with rated voltage 450/750V and below [IEC 60245 (all parts)]
Note. GB/T 5013.1-2008 Rubber insulated cables with rated voltage 450/750V and below Part 1.General requirements (IEC 60245-1.2003,
IDT);
GB/T 5013.2-2008 Rubber insulated cables with rated voltage 450/750V and below Part 2.Test methods (IEC 60245-2.1998,
IDT);
GB/T 5013.3-2008 Rubber insulated cables with rated voltage 450/750V and below Part 3.Heat-resistant silicone rubber insulated cables (IEC 60245-
3.1994,IDT);
GB/T 5013.4-2008 Rubber insulated cables with rated voltage 450/750V and below Part 4.Flexible wires and flexible cables (IEC 60245-4.
2004,IDT);
GB/T 5013.5-2008 Rubber insulated cables with rated voltage 450/750V and below Part 5.Elevator cables (IEC 60245-5.1994,
IDT);
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15092.2-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 15092.2-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15092.2-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15092.2-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15092.2-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15092.2-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|