US$169.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14797.2-2008: Natural rubber latex concentrate -- Prevulcanized rubber latex -- Determination of viscosity Status: Valid GB/T 14797.2: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14797.2-2008 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Natural rubber latex concentrate -- Prevulcanized rubber latex -- Determination of viscosity
| Valid |
GB/T 14797.2-2008
|
| GB/T 14797.2-1993 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Natural rubber latex concentrate. Prevulcanized rubber latex. Determination of viscosity
| Obsolete |
GB/T 14797.2-1993
|
PDF similar to GB/T 14797.2-2008
Basic data | Standard ID | GB/T 14797.2-2008 (GB/T14797.2-2008) | | Description (Translated English) | Natural rubber latex concentrate -- Prevulcanized rubber latex -- Determination of viscosity | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | B72 | | Classification of International Standard | 83.06 | | Word Count Estimation | 7,747 | | Date of Issue | 6/19/2008 | | Date of Implementation | 12/1/2008 | | Older Standard (superseded by this standard) | GB/T 14797.2-1993 | | Quoted Standard | GB/T 8290; GB/T 8298 | | Adopted Standard | ISO 1652-2004, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 10, 2008 (No. 123 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies a method for measuring the viscosity of vulcanized natural rubber latex with L-type rotary viscometer. This Standard is applicable to vulcanized natural rubber latex viscosity measurement, and also applies to natural rubber latex and natural rubber latex material prepared for the determination of the apparent viscosity of specialty latex. |
GB/T 14797.2-2008: Natural rubber latex concentrate -- Prevulcanized rubber latex -- Determination of viscosity ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Natural rubber latex concentrate-Prevulcanized rubber latex. Determination of viscosity
ICS 83.060
B72
National Standards of People's Republic of China
Replacing GB/T 14797.2-1993
Natural rubber latex concentrate vulcanized latex
Determination of viscosity
(ISO 1652.2004, Rubberlatex-Determinationofapparent
viscositybytheBrookfieldtest, MOD)
Posted 2008-06-19
2008-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This section GB/T Part of 214,797.
The partial modification of the use of ISO 1652.2004 "Determination of apparent viscosity latex viscometer Law" (in English).
This part of ISO 1652. The main difference compared to 2004 is as follows.
--- This section applies to vulcanized natural rubber latex, natural rubber latex also applies to natural rubber latex and latex raw material for the special preparation;
--- This section only provides L-type rotational viscometer one type of measuring instruments;
--- This section increases the measurement tolerance;
--- This section deleted Appendix A.
This Part replaces GB/T 14797.2-1993 "concentrated natural rubber latex vulcanized latex viscosity determination."
Section compared with the GB/T 14797.2-1993 The main changes are as follows.
--- Increased Chapter 3, "Terms and Definitions";
--- Original Chapter 3, "test principle" to Chapter 4, "principle", according to the content of ISO 1652.2004 modified;
--- Increased Chapter 6 sampling;
--- Increased Chapter 10, "tolerance", the other reg numbers make appropriate adjustments;
--- Deletion of Appendix A.
This section proposed by the People's Republic of China Ministry of Agriculture.
This part of the National Rubber and rubber products natural rubber Standardization Technical Committee Technical Committee (SAC/TC35/SC8)
Centralized.
This section drafted by. China Tropical Agricultural Sciences Institute of Agro.
The main drafters of this section. Chen Chenghai, Zhangbei Long, Huang Maofang.
This part of the standard replaces the previous editions are.
--- GB/T 14797.2-1993.
Natural rubber latex concentrate vulcanized latex
Determination of viscosity
Warning --- using GB/T 14797 in this section should be familiar with normal laboratory procedures. This section relates to unintentional result
All of the safety issues that may arise in this section. Users should establish appropriate safety and health rules, and to ensure compliance with the relevant national law
Regulatory requirements.
1 Scope
GB/T 14797 in this section specifies the method with L-type rotary viscometer vulcanized natural rubber latex viscosity.
This section applies to the determination of vulcanized natural rubber latex viscosity, also apply to natural latex and natural rubber latex as a raw material for preparing special latex
Determination of apparent viscosity.
2 Normative references
The following documents contain provisions which, through reference GB/T 14797 in this section, constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 8290 Natural rubber latex concentrate sampling (GB/T 8290-1987, neq ISO 123. 1985)
GB/T 8298 Natural rubber latex concentrate - Determination of total solids content (GB/T 8298-2001, eqv ISO 124.1997)
3 Terms and Definitions
The following terms and definitions apply GB/T 14797 in this section.
3.1
According to GB/T 8290 regulations take appropriate tests latex, stir as a laboratory sample.
Principle 4
A rotary viscometer viscosity, is about a specific rotor immersed in the latex to a predetermined depth, at a constant rotational frequency and controllable
Manufactured under a shear rate of rotation, in order to determine the torque generated by the latex viscosity. Used with the rotor rotational frequency and size of the transfer coefficients are multiplied by
Moments viscosity readings obtained. Undiluted or diluted to the desired total solids content of the latex can be measured.
This section relates to the principles of the viscometer model operated by hand, rather than operate with a finger. Now the best operating instructions.
5 Instruments
5.1 viscometer
Viscometer by a synchronous electric motor, the motor drive shaft at a constant rotational frequency axis can be connected to different shapes
And the size of the rotor. Speed \u200b\u200bdigital rotational frequency can be selected from the table. The intention of this section is to provide a speed, but speed is also actually the other
be usable. The rotor is immersed in the latex to a predetermined depth, the rotor is rotated in the latex, then, the rotor resistance will produce a shaft
Torque. The resulting balance of torque by the pointer indicates engraved with 0 to 100 scale units 1).
1) Suitable instruments can obtain from the following several places. such as BrookfieldEngineeringLaboratorie, Inc. , Stoughton, Mass. 02072,
USA (LVF LVT type and L-type instruments in line with requirements); GebruderHaakeGmbH, Dieselstr. 4, D-76227Karlsruhe, Ger-
many; Shanghai Precision Instrument Co., NDJ-1. This information is given for the convenience of users of this part, does not mean that this product
Recognition.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14797.2-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 14797.2-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14797.2-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14797.2-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 14797.2-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14797.2-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|