US$1259.00 · In stock Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14598.24-2017: Measuring relays and protection equipment -- Part 24: Common format for transient data exchange (COMTRADE) for power systems Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14598.24-2017 | English | 1259 |
Add to Cart
|
8 days [Need to translate]
|
Measuring relays and protection equipment -- Part 24: Common format for transient data exchange (COMTRADE) for power systems
| Valid |
GB/T 14598.24-2017
|
PDF similar to GB/T 14598.24-2017
Basic data | Standard ID | GB/T 14598.24-2017 (GB/T14598.24-2017) | | Description (Translated English) | Measuring relays and protection equipment -- Part 24: Common format for transient data exchange (COMTRADE) for power systems | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K45 | | Classification of International Standard | 29.120.70 | | Word Count Estimation | 63,623 | | Date of Issue | 2017-07-31 | | Date of Implementation | 2018-02-01 | | Older Standard (superseded by this standard) | GB/T 22386-2008 | | Quoted Standard | IEEE C37.118-2005; IEEE C37.232-2007; IEEE 260.1-1993; IEEE 280-1985; IEEE 754-2008; ISO 80000-1 | | Adopted Standard | IEC 60255-24-2013, IDT | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies a file format suitable for data files containing transient waveforms and events obtained from power systems or power system models. This standard specifies an easy-to-interpret data exchange format for files stored on various physical media for current applications, such as mobile hard drives, USB storage, flash memory, CDs and DVDs. This standard is not a communication format through network switching. GB / T 14598 of the standard provides a common exchange format for all types of failures, testing and simulation data files and switching media. With the power industry failure and transient data recording and testing of digital equipment continue to develop and application, put forward the demand for data exchange standard format. The application of these data will increase the power system |
GB/T 14598.24-2017: Measuring relays and protection equipment -- Part 24: Common format for transient data exchange (COMTRADE) for power systems ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Measuring relays and protection equipment. Part 24. Common format for transient data exchange (COMTRADE) for power systems
ICS 29.120.70
K45
National Standards of People's Republic of China
Replacing GB/T 22386-2008
Measuring relays and protection devices
Part 24. Power system transient data
Exchange (COMTRADE) common format
Measuringrelaysandprotectionequipment-Part 24.Commonformatfor
transientdataexchange (COMTRADE) forpowersystems
(IEC 60255-24.2013, IDT)
2017-07-31 Posted
2018-02-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 files and data storage 2
4.1 Document Category 2
4.2 Required/Optional Data 3
4.3 Data Presentation 3
4.4 Data Domain Separator and Length 4
4.5 ASCII data floating-point representation 4
4.6 ways to access the data in the file 5
4.7 once/twice the ratio of 6
5 COMTRADE file 6
5.1 Overview 6
5.2 header files (.HDR) 6
5.3 Configuration File (.CFG) 6
5.4 Data Files (.DAT) 7
5.5 Information File (.INF) 7
6 files 7
6.1 Overview 7
6.2 Contents 7
6.3 file name 8
6.4 format 8
7 profile 8
7.1 Overview 8
7.2 Contents 8
7.3 File Name 8
7.4 Format 8
7.5 missing content in the configuration file 14
7.6 configuration file format design 14
8 data files 14
8.1 Overview 14
8.2 Content 15
8.3 Data File Name 15
8.4 ASCII Data File Format 15
8.5 ASCII Data Sample 16
8.6 Binary Data Files 16
8.7 Sample Binary Data Sample 17
Information file
9.1 Overview 17
9.2 Contents 18
9.3 Information file name 18
9.4 Information File Structure 18
9.5 Document Features 19
9.6 District head 19
9.7 entry line 20
9.8 Add, modify and delete information 21
9.9 Common Area Header and Entry Line Definition 21
9.10 Common record information area 21
9.11 Utility Information Definition 22
9.12 Public document description area 23
9.13 Common analog channel area 24
9.14 Common Status Channel Area 25
Example 9.15 .INF File 25
10 single file COMTRADE format (with .CFF extension) 27
Appendix A (informative) time series data sources and exchange media 29
Appendix B (informative) data exchange sampling rate of 31
Appendix C (Informative) Sample Documents 35
Appendix D (Informative) Sampling frequency conversion sampling procedures 42
Appendix E (informative) conversion factor application example 45
Appendix F (Informative) Example COMTRADE File with CFF Extension (ASCII Data) 46
Appendix G (Informative) COMTRADE File Example with CFF Extension (Binary Data) 48
Appendix H (informative) COMTRADE document standard applied to the phasor data program 49
References 56
Foreword
"Measuring relays and protection devices" is divided into the following sections.
--- GB/T 14598.1 electrical relays Part 23. Contact performance;
--- GB/T 14598.2 measuring relays and protection devices Part 1. General requirements;
--- GB/T 14598.3 electrical relays Part 5. Measuring relays and protective devices with the requirements of insulation and testing;
--- GB/T 14598.4 electrical relays Part 14. Electrical relay contact life test contact excellent load
First value
--- GB/T 14598.5 electrical relays Part XV. Electrical relay contact life test test equipment characteristics
specification;
--- GB/T 14598.6 electrical relays Part XVIII with or without general-purpose relay size;
--- GB/T 14598.8 electrical relays Part 20. Protection system;
--- GB/T 14598.24 Measuring relays and protection equipment Part 24. Power System Transient Data Exchange
(COMTRADE) common format;
--- GB/T 14598.26 Measuring relays and protection devices - Part 26. Electromagnetic compatibility requirements;
--- GB 14598.27 Measuring relays and protection devices - Part 27. Product safety requirements;
--- GB/T 14598.121 Measuring relays and protection equipment Part 121. Distance protection requirements;
--- GB/T 14598.127 Measuring relays and protection devices Part 127. Over/under voltage protection function requirements;
--- GB/T 14598.149 Measuring relays and protection devices Part 149. Functional requirements of electric relays;
--- Measuring relays and protection equipment GB/T 14598.151 Part 151. Over/under current protection function requirements;
--- GB/T 14598.300 computer transformer protection device general technical requirements;
--- GB/T 14598.301 microcomputer generator transformer fault recording device technical requirements;
--- GB/T 14598.302 arc protection device technical requirements;
--- GB/T 14598.303 digital motor general protection device general technical conditions.
This section GB/T 14598 Part 24.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section instead of GB/T 22386-2008 "power system transient data exchange common format", compared with GB/T 22386-2008,
The main technical differences.
--- The new version allows the use of a single file format (with. CFF suffix) file instead of four separate files;
A single file with a .CFF suffix contains 4 partitions, corresponding to .CFG, .INF, .HDR, and .DAT, respectively. DAT partition both
Can be ASCII format can also be Binary format;
--- Support binary32 and float32 data types;
---. CFG file format revision. The end of the .CFG added time-related two lines of a total of four domain content;
---. CFG part of the file can be amended as a mandatory option;
--- Added UnicodeUTF-8 format support.
This section uses the translation method identical with IEC 60255-24.2013 "Measuring relays and protection devices Part 24. Power System temporarily
Common Format Data Exchange (COMTRADE) "(in English).
This part is proposed by China Electrical Equipment Industry Association.
This part of the National Measurement Relay and Protection Equipment Standardization Technical Committee (SAC/TC154) centralized.
This part of the main drafting unit. Nanrui Nanjing Electric Co., Ltd. following security, Xuchang Cape Detection Technology Co., Ltd., Beijing Sifugi following Paul from
Motion Co., Ltd., Xuchang Cape Electric Institute, Xuji Electric Co., Ltd., China Southern Power Grid Power Dispatching Control Center, the country
Gansu Provincial Power Company, State Grid Shandong Electric Power Company, State Grid Hebei Electric Power Co., Ltd., State Grid Hebei Electric Power Company, State Power Nanjing Automatic
Co., Ltd., Long Park, Shenzhen Rui Bao Automation Co., Ltd., Beijing Purple Measurement and Control Co., Ltd., Semiconductor Co., Ltd., the East
Electronics Co., Ltd., State Grid Electric Power Research Institute, Schneider Electric China Ltd., Siemens Power Automation Co., Ltd., State Power
NARI Technology Co., Ltd., Baoding Lang Baidi Electric Co., Ltd., Wuhan Zhongyuan Huadian Technology Co., Ltd., Wuhan Guodian
Electric Co., Ltd.
The main drafters of this section. Wang Liang, Zhang Ran, Wu Fang Ying, Yang Huixia, Wang Liye, Zhang Chi, Zheng Wei, Li Lei, Hao Yipeng, Zhao Peng, Tao Liang,
Sun Yimin, Li Ming, Congchun Cong, Liu Haibo, He Chun, Yang Jia, Qi Yankang, Hook, Zhang Zhaoyun, Zheng Yanfeng, Feng Weigang, Wang Pengfei.
This standard replaces the standards previously issued as.
--- GB/T 22386-2008.
Introduction
With the rapid development of the application of digital technology, various protection, recording, measuring and controlling equipment of substation in the transient event of power system
Will accumulate a large number of digital records. In addition, analog and digital power system simulations produce digital records as well. The use of these records
Are facing the problem of handling different data formats generated, stored and transmitted by various systems.
Measuring relays and protection devices
Part 24. Power system transient data
Exchange (COMTRADE) common format
1 Scope
This section GB/T 14598 defines a file format that applies to contain the transient obtained from the power system or power system model
Waveform and event data files. This section provides an easy-to-interpret data exchange format suitable for storage in a variety of current applications
Files on physical media, such as removable media, USB storage, flash memory, CDs and DVDs. This section does not communicate through the Internet
format.
This section GB/T 14598 defines a common exchange format for a variety of fault, test and simulation data files and
Exchange media. With the continuous development and application of fault and transient digital data recording and testing in the power industry, a data exchange
The standard format of the demand. The application of these data will improve the analysis of the power system and its protection control measures in case of disturbance disturbance,
Testing, evaluation and simulation of the automation level. Because each data source may use a different proprietary format, define a can promote these data
A common format for switching between different devices is necessary, which facilitates the exchange and use of private data between different applications and also permits private
The system uses data from other systems.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEEEC37.118-2005 Power system synchronous phasor device (IEE EStandardforSynchrophasorsforPower
Systems)
IEEEC37.232-2007 Recommended Practice for Named Timing Data Files (IEEERecommendedPracticeforNa-a-
mingTimeSequenceDataFiles)
IEEE260.1-1993 Unit of measure alphabetical symbols (SI units, commonly used inches - pounds units and other units)
[IEEEStandardLetterSymbolsForUnitsof Measurement (SIUnits, CustomaryInch-Pound
Units)]
IEEE 280-1985 Electrotechnical and Electrical Engineering used in the value of the alphabetic symbols (IEEEStandardLetterSymbols
for Quantities Electric in Electronic Science and Electrical Engineering)
IEEE754-2008 floating-point arithmetic (IEEEStandardforFloatingPointArithmetic)
ISO 80000-1 volumes and units Part 1. General (Quantitiesandunits-Part 1.General)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Required data criticaldata
Any data necessary to reproduce the sample data.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14598.24-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 14598.24-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14598.24-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14598.24-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|