HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 14048.23-2022 English PDF

US$339.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14048.23-2022: Low-voltage switchgear and controlgear - Part 9-1: Active arc-fault mitigation systems - Arc quenching devices
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14048.23-2022English339 Add to Cart 4 days [Need to translate] Low-voltage switchgear and controlgear - Part 9-1: Active arc-fault mitigation systems - Arc quenching devices Valid GB/T 14048.23-2022

PDF similar to GB/T 14048.23-2022


Standard similar to GB/T 14048.23-2022

GB/T 14048.5   GB/T 14048.6   GB 16916.1   GB/Z 14048.24   GB/T 14048.22   GB/T 14048.14   

Basic data

Standard ID GB/T 14048.23-2022 (GB/T14048.23-2022)
Description (Translated English) Low-voltage switchgear and controlgear - Part 9-1: Active arc-fault mitigation systems - Arc quenching devices
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K31
Classification of International Standard 29.120.40; 29.130.20
Word Count Estimation 18,182
Date of Issue 2022-10-14
Date of Implementation 2023-05-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 14048.23-2022: Low-voltage switchgear and controlgear - Part 9-1: Active arc-fault mitigation systems - Arc quenching devices


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear -- Part 9-1.Active arc-fault mitigation systems -- Arc quenching devices ICS 29.120.40; 29.130.20 CCSK31 National Standards of People's Republic of China Low-voltage switchgear and controlgear Part 9-1.Active Arc Fault Suppression Systems Arc extinguishing appliance Published on 2022-10-12 2023-05-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction V 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Category 2 4.1 According to the number of operations divided into 2 4.2 According to the installation characteristics, it is divided into 2 5 Feature 3 5.1 Rated working voltage (Ue) 3 5.2 Rated insulation voltage (Ui) 3 5.3 Rated impulse withstand voltage (Uimp) 3 5.4 Rated short-time withstand current (Icw) 3 5.5 Maximum voltage drop in low impedance state3 5.6 Maximum operating time 3 5.7 Number of operating cycles (resettable AQD) 3 5.8 Maximum allowable temperature of AQD main circuit terminals3 6 Product Information 3 6.1 Types of information 3 6.2 Flag 3 6.3 Instructions for installation, operation, maintenance, shutdown and disassembly 4 7 Normal use, installation and transport conditions 4 8 Structure and performance requirements 4 8.1 Structural Requirements 4 8.2 Performance requirements5 8.3 Electromagnetic Compatibility (EMC) 5 9 Experiment 5 9.1 Test Type 5 9.2 Verification Structure Requirements 5 9.3 Type test 5 9.4 Routine test 8 Appendix A (Informative) Principles for Defining Maximum Voltage Drop in Low Impedance State 9 A.1 Arc extinguishing conditions 9 A.2 Determination of minimum distance and corresponding voltage drop9 Reference 11

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. This document is part 9-1 of GB/T 14048 "Low-voltage switchgear and controlgear". GB/T 14048 has issued the following part. --- Part 1.General; --- Part 2.Circuit breakers; --- Part 3.Switches, isolators, isolating switches and fuse combinations; --- Part 4-1.Contactors and motor starters Electromechanical contactors and motor starters (including motor protectors); --- Part 4-2.Contactors and motor starters Semiconductor controllers and starters for AC motors (including soft starters); --- Part 4-3.AC semiconductor controllers and contactors for contactors and motor starters for non-motor loads; --- Part 5-1.Control circuit appliances and switching elements electromechanical control circuit appliances; --- Part 5-2.Control circuit electrical appliances and switching elements proximity switches; --- Part 5-3.Proximity switches (PDDB) with deterministic functions under fault conditions for control circuit appliances and switching elements Require; --- Part 5-4.Special test for performance evaluation methods of small-capacity contacts of control circuit appliances and switching elements; --- Part 5-5.Electrical emergency braking devices with mechanical latch function for control circuit appliances and switching elements; --- Part 5-6.Control circuit electrical appliances and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR); --- Part 5-7.Requirements for control circuit appliances and switching elements for proximity devices with analog outputs; --- Part 5-8.Three-position enabling switches for control circuit electrical appliances and switching elements; --- Part 5-9.Control circuit electrical appliances and switching elements flow switches; --- Part 6-1.Multifunctional electrical transfer switch electrical appliances; --- Part 6-2.Multifunctional electrical appliances (equipment) control and protection switch electrical appliances (equipment) (CPS); --- Part 7-1.Terminal blocks for copper conductors of auxiliary devices; --- Part 7-2.Protective conductor terminal block for copper conductors of auxiliary devices; --- Part 7-3.Safety requirements for auxiliary device fuse terminal blocks; --- Part 7-4.PCB terminal block for copper conductors of auxiliary devices; --- Part 8.Built-in thermal protection (PTC) control unit for rotating electrical machines; --- Part 9-1.Arc-fault active suppression system arc extinguishing appliances. This document is modified to adopt IEC 60947-9-1.2019 "Low-voltage switchgear and controlgear - Part 9-1.Active suppression of arc faults" System Arc Extinguisher. The technical differences between this document and IEC 60947-9-1.2019 and their reasons are as follows. ---Replace IEC 60947-1.2007, IEC 60947-1.2007/AMD1 with normative reference IEC 60947-1.2020. 2010 and IEC 60947-1.2007/AMD2.2014 (see Chapter 2, Chapter 3, 5.1~5.3, 6.1, 6.3, Chapter 7~9 Chapter), the reason is to be consistent with the latest edition of IEC 60947-1, and thus refer to the relevant IEC 60947-1.2020 The following technical differences arise in the terms. ● Changed terms and definitions (see Chapter 3); ● Added relevant requirements for deactivation and disassembly (see 6.3); ● Added requirements for insulating cooperating spacers for creepage distances, insulating cooperating spacers for electrical clearances, and continuity of protective grounding and test requirements (see 8.1 and 9.2); ● Added DC withstand voltage requirements for dielectric properties (see 8.2, 9.3.1.2.6, 9.3.1.3.5 and 9.3.1.3.7); ● Changed the launch test requirements (see 8.3 and 9.3.2.2); ● Added modification of special test (see 9.1). --- Replaced CISPR11.2015 and CISPR11.2015/AMD1.2016 with normatively cited CISPR11.2019 (see Chapter 2, 9.3.2.2), the reason is for consistency with the latest version of CISPR11, and is hereby referenced in CISPR11.2019 The following technical differences have arisen in the relevant provisions of. ● Added the applicable equipment for the limit requirements of low-voltage DC power supply ports; ● Added the measurement requirements for the medium and low voltage DC power supply ports in the conducted disturbance limit. The following editorial changes have been made to this document. --- Change IEC 60417 in Chapter 2 to IEC 60417.2002, which is consistent with the standard cited in Chapter 6 of the original text; --- Number all the formulas in Appendix A, and explain the contents of the formulas. Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Standardization Technical Committee for Low-voltage Electrical Appliances (SAC/TC189). This document is drafted by. Shanghai Electric Apparatus Research Institute, Changshu Switch Manufacturing Co., Ltd. (formerly Changshu Switch Factory), Zhongshan Kaipu Electric Co., Ltd., Zhejiang Chint Electric Co., Ltd., Shanghai Liangxin Electric Co., Ltd., Hongxiu Electric Co., Ltd., Shengli Oilfield Hengyuan Electric Co., Ltd., Jiangsu Mitre Internet of Things Technology Co., Ltd. The main drafters of this document. Wang Yuxuan, Yi Ying, Zhou Jianxing, Zou Jianhua, Guo Dexin, Duan Hui, Qian Jiangbo, Zhao Yunde, Zhang Jianxing.

Introduction

Low-voltage switchgear and control equipment is a large-scale and wide-ranging industry. The products involve. circuit breakers, isolators, isolating switches and fuse sets It is widely used in various fields such as machinery, electricity, electronics, etc., involving the control, distribution and other aspects of electric energy. noodle. GB/T 14048 "Low-voltage switchgear and control equipment" is an important system for guiding low-voltage switchgear and control equipment related products in my country. The column standard is to be composed of 25 parts. --- Part 1.General. The purpose is to specify general requirements for low-voltage switchgear and controlgear. --- Part 2.Circuit breakers. The purpose is to specify product-related requirements such as performance requirements and test methods of circuit breakers. --- Part 3.Switches, isolators, isolating switches and fuse combinations. The purpose is to specify switches, isolators, isolating switches And the performance requirements and test methods of fuse combination electrical appliances and other product-related requirements. --- Part 4-1.Contactors and motor starters Electromechanical contactors and motor starters (including motor protectors). target The purpose is to specify the performance requirements and test methods of electromechanical contactors and motor starters (including motor protectors) off requirements. --- Part 4-2.Contactors and motor starters Semiconductor controllers and starters (including soft starters) for AC motors. The purpose is to specify the performance requirements and test methods of semiconductor controllers and starters (including soft starters) for AC motors. product related requirements. --- Part 4-3.AC semiconductor controllers and contactors for contactors and motor starters for non-motor loads. aim at It specifies product-related requirements such as performance requirements and test methods for AC semiconductor controllers and contactors for non-motor loads. --- Part 5-1.Control circuit appliances and switching elements Electromechanical control circuit appliances. The purpose is to specify electromechanical control Product-related requirements such as performance requirements and test methods of electrical appliances. --- Part 5-2.Control circuit electrical appliances and switching elements proximity switches. The purpose is to specify the performance requirements and test of the proximity switch. Test methods and other product-related requirements. --- Part 5-3.Requirements for proximity switches (PDDB) with specified functions for control circuit appliances and switching elements under fault conditions beg. The purpose is to specify product-related performance requirements and test methods for proximity switches with definite functions under fault conditions. Require. --- Part 5-4.Special test for the performance evaluation method of small-capacity contacts of control circuit appliances and switching elements. the purpose is Specifies the special test requirements in the performance evaluation of small capacity contacts. --- Part 5-5.Control circuit electrical appliances and switching elements electrical emergency braking devices with a mechanical latch function. the purpose is Specifies product-related requirements such as performance requirements and test methods for electrical emergency braking devices with mechanical latch function. --- Part 5-6.Control circuit electrical appliances and switching elements Proximity sensors and switching amplifiers DC interface (NAMUR). The purpose is to specify product-related requirements such as performance requirements and test methods for the DC interface of proximity sensors and switching amplifiers. --- Part 5-7.Requirements for control circuit appliances and switching elements for proximity devices with analog outputs. The purpose is to stipulate Product-related requirements such as performance requirements and test methods for proximity devices with analog outputs. --- Part 5-8.Three-position enabling switch for control circuit electrical appliances and switching elements. The purpose is to specify the performance of the three-position enabling switch Product-related requirements such as requirements and test methods. --- Part 5-9.Control circuit appliances and switching elements flow switches. The purpose is to specify the performance requirements and test of the flow switch. Test methods and other product-related requirements. --- Part 6-1.Multifunctional electrical transfer switch electrical appliances. The purpose is to specify the performance requirements and test methods of transfer switch appliances. Law and other product-related requirements. --- Part 6-2.Multifunctional electrical (equipment) control and protection switch electrical appliances (equipment) (CPS). The purpose is to provide for control and protection Product-related requirements such as performance requirements and test methods of protective switch appliances. --- Part 7-1.Terminal block for copper conductors of auxiliary devices. The purpose is to specify the performance requirements of the terminal block of copper conductors. Seek and test methods and other product-related requirements. --- Part 7-2.Protective conductor terminal block for copper conductors of auxiliary devices. The purpose is to specify the protective conductor connection of copper conductors. Product-related requirements such as performance requirements and test methods of wire terminal blocks. --- Part 7-3.Safety requirements for auxiliary device fuse terminal blocks. The purpose is to specify the fuse terminal block Safety related requirements. --- Part 7-4.PCB terminal block for copper conductors of auxiliary devices. The purpose is to specify a PCB terminal block for copper conductors Product-related requirements such as performance requirements and test methods. --- Part 7-5.Terminal blocks for aluminum conductors of auxiliary devices. The purpose is to specify the performance requirements of terminal blocks of aluminum conductors. Seek and test methods and other product-related requirements. --- Part 8.Built-in thermal protection (PTC) control unit for rotating electrical machines. The purpose is to specify built-in thermal protection for rotating electrical machines. Product-related requirements such as performance requirements and test methods of the protection (PTC) control unit. --- Part 9-1.Arc-fault active suppression system arc extinguishing appliances. The purpose is to specify the performance requirements and tests of arc extinguishing appliances Methods and other product-related requirements. --- Part 9-2.Arc fault active suppression system Internal arc detection and suppression equipment based on optical signals. The purpose is to regulate Product-related requirements such as performance requirements and test methods for internal arc detection and suppression equipment based on optical signals. As people pay more and more attention to the impact of arc faults inside complete sets of equipment, there has been a need to prevent such internal arc faults. Protection mode, which can be achieved by passive components (suppression) or active components, also known as "active arc fault suppression system". Arc fault active suppression systems typically use an internal arc fault based on arcing effects (light, pressure, current or voltage harmonics, etc.) Control appliance (IACD) and an actuator to suppress arcing. The actuator can be a circuit breaker upstream of the line, which trips to cut off the fault current, or an arc extinguisher that can The upstream short-circuit protection device directs the fault current to a dedicated low-impedance loop before cutting the circuit. The arc extinguishing device specified in this document is an electric An important link in the arc fault active suppression system. Low-voltage switchgear and controlgear Part 9-1.Active Arc Fault Suppression Systems Arc extinguishing appliance

1 Scope

This document applies to low-voltage arc extinguishing equipment, referred to as AQD, which eliminates low-voltage complete sets of equipment (symbol) by forming a low-impedance current loop. arc faults in typical low-voltage switchgear and controlgear conforming to the IEC 61439 series, so that the arcing current is transferred to a new current return road. This new current loop will be maintained until the short-circuit protection device (SCPD) interrupts the short-circuit current. These appliances are installed on the main distribution line of the low-voltage plant, preferably as close to the mains as possible. The rated voltage does not exceed AC 1000V or DC 1500V. This document does not include. --- Sensors for detecting arc faults; --- Electrical appliances for triggering the function of arc extinguishing appliances; --- Appliances for cutting off arc fault currents; --- Special requirements for AQD used in explosive atmospheres (eg ATEX).

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB/T 2423.4-2008 Environmental testing of electrical and electronic products - Part 2.Test method Test Db. Alternating damp heat (12h 12h cycle) (IEC 60068-2-30.2005, IDT) Note. GB/T 5465.1-2009 Graphical Symbols for Electrical Equipment Part 1.Overview and Classification (IEC 60417DB.2007-01, MOD); GB/T 5465.2-2008 Graphical symbols for electrical equipment - Part 2.Graphical symbols (IEC 60417DB.2007, IDT). trolgear-Part 1.Generalrules) Note. GB/T 14048.1-2012 Low-voltage switchgear and control equipment - Part 1.General (IEC 60947-1.2011, MOD). assemblies) Note. GB/T 7251 (all parts) Low-voltage switchgear and control equipment [IEC 61439 (all parts)]. CISPR11.2019 Limits and methods of measurement of radio frequency disturbance characteristics of industrial, scientific and medical equipment (Industrial, scientific urement) Note. GB 4824-2019 Limits and Measurement Methods of Radio Frequency Disturbance Characteristics of Industrial, Scientific and Medical Equipment (CISPR11.2016, IDT).

3 Terms and Definitions

The terms and definitions defined in IEC 60947-1.2020 and the following terms and definitions apply to this document.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14048.23-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14048.23-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14048.23-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14048.23-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.