HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 14048.22-2022 English PDF

US$629.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14048.22-2022: Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors
Status: Valid

GB/T 14048.22: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14048.22-2022English629 Add to Cart 5 days [Need to translate] Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors Valid GB/T 14048.22-2022
GB/T 14048.22-2017EnglishRFQ ASK 4 days [Need to translate] Low-voltage switchgear and controlgear -- Part 7-4: Ancillary equipment -- PCB terminal blocks for copper conductors Obsolete GB/T 14048.22-2017

PDF similar to GB/T 14048.22-2022


Standard similar to GB/T 14048.22-2022

GB/T 14048.11   GB/T 14048.3   GB 14048.1   GB/Z 14048.24   GB/T 14048.23   GB/T 14048.14   

Basic data

Standard ID GB/T 14048.22-2022 (GB/T14048.22-2022)
Description (Translated English) Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K30
Classification of International Standard 29.130.20
Word Count Estimation 34,344
Date of Issue 2022-10-14
Date of Implementation 2023-05-01
Older Standard (superseded by this standard) GB/T 14048.22-2017
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 14048.22-2022: Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear -- Part 7-4.Ancillary equipment -- PCB terminal blocks for copper conductors ICS 29.130.20 CCSK30 National Standards of People's Republic of China Replacing GB/T 14048.22-2017 Low-voltage switchgear and controlgear Part 7-4.Auxiliary Devices PCB terminal block for copper conductors (IEC 60947-7-4.2019,MOD) Published on 2022-10-12 2023-05-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction V 1 Scope 1 2 Normative references 1 3 Terms and Definitions 3 4 Category 4 5 Feature 4 6 Product Information 6 7 Normal use, installation and transport conditions 7 8 Requirements for construction and performance 7 9 trial 10 Appendix A (Informative) Structure of PCB Terminal Block 22 Appendix B (informative) Additional information to be agreed between manufacturer and user23 Appendix C (Informative) Examples of PCB and PCB Terminal Blocks for High Current 24 Reference 26

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. This document is part 7-4 of GB/T 14048.GB/T 14048 "Low-voltage switchgear and control equipment" has released the following part. --- Part 1.General; --- Part 2.Circuit breakers; --- Part 3.Switches, isolators, isolating switches and fuse combinations; --- Part 4-1.Contactors and motor starters Electromechanical contactors and motor starters (including motor protectors); --- Part 4-2.Contactors and motor starters Semiconductor controllers and starters for AC motors (including soft starters); --- Part 4-3.AC semiconductor controllers and contactors for contactors and motor starters for non-motor loads; --- Part 5-1.Control circuit appliances and switching elements electromechanical control circuit appliances; --- Part 5-2.Control circuit electrical appliances and switching elements proximity switches; --- Part 5-3.Proximity switches (PDDB) with deterministic functions under fault conditions for control circuit appliances and switching elements Require; --- Part 5-4.Special test for performance evaluation methods of small-capacity contacts of control circuit appliances and switching elements; --- Part 5-5.Electrical emergency braking devices with mechanical latch function for control circuit appliances and switching elements; --- Part 5-6.Control circuit electrical appliances and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR); --- Part 5-7.Requirements for control circuit appliances and switching elements for proximity devices with analog outputs; --- Part 5-8.Three-position enabling switches for control circuit electrical appliances and switching elements; --- Part 5-9.Control circuit electrical appliances and switching elements flow switches; --- Part 6-1.Multifunctional electrical transfer switch electrical appliances; --- Part 6-2.Multifunctional electrical appliances (equipment) control and protection switch electrical appliances (equipment) (CPS); --- Part 7-1.Terminal blocks for copper conductors of auxiliary devices; --- Part 7-2.Protective conductor terminal block for copper conductors of auxiliary devices; --- Part 7-3.Safety requirements for auxiliary device fuse terminal blocks; --- Part 7-4.PCB terminal block for copper conductors of auxiliary devices; --- Part 8.Built-in thermal protection (PTC) control unit for rotating electrical machines; --- Part 9-1.Arc-fault active suppression system arc extinguishing appliances. This document replaces GB/T 14048.22-2017 "Low-voltage switchgear and control equipment - Part 7-4.Auxiliary device copper conductors Compared with GB/T 14048.22-2017, in addition to structural adjustment and editorial changes, the main technical changes are as follows. --- Changed the minimum cross-sectional area of copper conductors applicable to this document from 0.05mm2 to 0.08mm2 (see Chapter 1, 5.3.5, Table 1 and Table 2, Chapter 1, 4.3.5, Table 1 and Table 2 of the.2017 edition); --- Changed the definition of the upper temperature limit (ULT) to clarify that the maximum temperature of the PCB terminal block is specified by the manufacturer (see 3.5, 2.5 of the.2017 edition); --- Changed the structural requirements of the clamping parts, the contact pressure can be transmitted through the insulating material (see 8.1.1, 7.1.1 of the.2017 edition); --- Added supplementary performance requirements and test methods for screwless PCB terminal blocks in the aging test (see 8.2.5.2, 9.4.7.2), supplementary performance requirements and test methods for PCB terminal blocks that transmit contact pressure through insulating materials (see 8.2.5.3, 9.4.7.3, Figure 5 and Figure 6); --- Added the tightening torque requirements for a threaded type of PCB terminal block (see 9.3.2, Table 4); --- Changed the test basis for verifying contact resistance (see 9.4.4, 8.4.4 of the.2017 edition); --- Changed the base area requirements of the PCB terminal block test assembly in the temperature rise test (see 9.4.5, 8.4.5 of the.2017 edition); --- Changed the test procedures and test product requirements for climate procedure tests and corrosion tests (see 9.4.7.1, Figure 4, 8.4.7 of the.2017 edition, Figure 4). This document is modified by IEC 60947-7-4.2019 "Low-voltage switchgear and controlgear-Part 7-4.Copper conductors for auxiliary devices The PCB terminal block". The technical differences between this document and IEC 60947-7-4.2019 and their reasons are as follows. ---Replace IEC 60947-1.2007, IEC 60947-1.2007/AMD1 with normative reference IEC 60947-1.2020. 2010 and IEC 60947-1.2007/AMD2.2014 (see Chapter 1, Chapter 2, Chapter 4, 5.3.1, Chapter 7~9 Chapter), the reason is to be consistent with the latest edition of IEC 60947-1, and thus refer to the relevant IEC 60947-1.2020 The following technical differences arise in the terms. ● Changed the general requirements for dielectric properties (see 8.2.2); ● Changed the requirements for the launch test (see 8.3); ● Changed the verification requirements for the impulse withstand voltage of dielectric properties (see 9.4.2.2); ● Changed the general requirements for EMC testing (see 9.6.1). --- Replace ISO 6988 with the normative reference GB/T 9789-2008 (see 9.4.7.1). Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Standardization Technical Committee for Low-voltage Electrical Appliances (SAC/TC189). This document is drafted by. Shanghai Electric Apparatus Research Institute, Wanke Electronics (Tianjin) Co., Ltd., Chengdu Ruilian Electric Co., Ltd., Shanghai Hailiangxin Electric Co., Ltd., Shanghai Tianwei Certification Technology Co., Ltd. The main drafters of this document. Jia Feng, Gu Meng, Wang Fang, Yu Bin, Zhu Junjie, Dong Hui. The previous versions of this document and its superseded documents are as follows. ---First released in.2017 as GB/T 14048.22-2017; ---This is the first revision.

Introduction

Low-voltage switchgear and control equipment is a large-scale and wide-ranging industry, with products such as circuit breakers, isolators, isolating switches and fuses Combined electrical appliances, contactors and starters are widely used in various fields such as machinery, electricity, electronics, etc., involving the control and distribution of electrical energy. aspect. GB/T 14048 "Low-voltage switchgear and control equipment" is an important guide for low-voltage switchgear and control equipment related products in my country. A series of standards, to be composed of 25 parts. --- Part 1.General. The purpose is to specify general requirements for low-voltage switchgear and controlgear. --- Part 2.Circuit breakers. The purpose is to specify product-related requirements such as performance requirements and test methods of circuit breakers. --- Part 3.Switches, isolators, isolating switches and fuse combinations. The purpose is to specify switches, isolators, isolating switches And the performance requirements and test methods of fuse combination electrical appliances and other product-related requirements. --- Part 4-1.Contactors and motor starters Electromechanical contactors and motor starters (including motor protectors). target The purpose is to specify the performance requirements and test methods of electromechanical contactors and motor starters (including motor protectors) off requirements. --- Part 4-2.Contactors and motor starters Semiconductor controllers and starters (including soft starters) for AC motors. The purpose is to specify the performance requirements and test methods of semiconductor controllers and starters (including soft starters) for AC motors. product related requirements. --- Part 4-3.AC semiconductor controllers and contactors for contactors and motor starters for non-motor loads. aim at It specifies product-related requirements such as performance requirements and test methods for AC semiconductor controllers and contactors for non-motor loads. --- Part 5-1.Control circuit appliances and switching elements Electromechanical control circuit appliances. The purpose is to specify electromechanical control Product-related requirements such as performance requirements and test methods of electrical appliances. --- Part 5-2.Control circuit electrical appliances and switching elements proximity switches. The purpose is to specify the performance requirements and test of the proximity switch. Test methods and other product-related requirements. --- Part 5-3.Requirements for proximity switches (PDDB) with specified functions for control circuit appliances and switching elements under fault conditions beg. The purpose is to specify product-related performance requirements and test methods for proximity switches with definite functions under fault conditions. Require. --- Part 5-4.Special test for the performance evaluation method of small-capacity contacts of control circuit appliances and switching elements. The purpose is to regulate Special test requirements in the performance evaluation of fixed and small-capacity contacts. --- Part 5-5.Control circuit electrical appliances and switching elements electrical emergency braking devices with a mechanical latch function. the purpose is Specifies product-related requirements such as performance requirements and test methods for electrical emergency braking devices with mechanical latch function. --- Part 5-6.Control circuit electrical appliances and switching elements Proximity sensors and switching amplifiers DC interface (NAMUR). The purpose is to specify product-related requirements such as performance requirements and test methods for the DC interface of proximity sensors and switching amplifiers. --- Part 5-7.Requirements for control circuit appliances and switching elements for proximity devices with analog outputs. The purpose is to stipulate Product-related requirements such as performance requirements and test methods for proximity devices with analog outputs. --- Part 5-8.Three-position enabling switch for control circuit electrical appliances and switching elements. The purpose is to specify the performance of the three-position enabling switch Product-related requirements such as requirements and test methods. --- Part 5-9.Control circuit appliances and switching elements flow switches. The purpose is to specify the performance requirements and test of the flow switch. Test methods and other product-related requirements. --- Part 6-1.Multifunctional electrical transfer switch electrical appliances. The purpose is to specify the performance requirements and test methods of transfer switch appliances and other product-related requirements. --- Part 6-2.Multifunctional electrical (equipment) control and protection switch electrical appliances (equipment) (CPS). The purpose is to provide for control and protection Product-related requirements such as performance requirements and test methods of protective switch appliances. --- Part 7-1.Terminal block for copper conductors of auxiliary devices. The purpose is to specify the performance requirements of the terminal block of copper conductors. Seek and test methods and other product-related requirements. --- Part 7-2.Protective conductor terminal block for copper conductors of auxiliary devices. The purpose is to specify the protective conductor connection of copper conductors. Product-related requirements such as performance requirements and test methods of wire terminal blocks. --- Part 7-3.Safety requirements for auxiliary device fuse terminal blocks. The purpose is to specify the fuse terminal block Safety related requirements. --- Part 7-4.PCB terminal block for copper conductors of auxiliary devices. The purpose is to specify a PCB terminal block for copper conductors Product-related requirements such as performance requirements and test methods. --- Part 7-5.Terminal blocks for aluminum conductors of auxiliary devices. The purpose is to specify the performance requirements of terminal blocks of aluminum conductors. Seek and test methods and other product-related requirements. --- Part 8.Built-in thermal protection (PTC) control unit for rotating electrical machines. The purpose is to specify built-in thermal protection for rotating electrical machines. Product-related requirements such as performance requirements and test methods of the protection (PTC) control unit. --- Part 9-1.Arc-fault active suppression system arc extinguishing appliances. The purpose is to specify the performance requirements and tests of arc extinguishing appliances Methods and other product-related requirements. --- Part 9-2.Arc fault active suppression system Internal arc detection and suppression equipment based on optical signals. The purpose is to regulate Product-related requirements such as performance requirements and test methods for internal arc detection and suppression equipment based on optical signals. This document considers not only the requirements for terminal blocks, but also the requirements for connectors specified in IEC 61984.2008, both due to The uses are similar, so the related requirements are also very similar. Since the corrosion test in this document already includes requirements for moisture resistance, the There is no need for additional moisture resistance test for the PCB terminal block. Low-voltage switchgear and controlgear Part 7-4.Auxiliary Devices PCB terminal block for copper conductors

1 Scope

This document specifies the requirements for PCB terminal blocks intended primarily for industrial or similar purposes. The copper conductors are mounted or fixed on the printed circuit board by soldering, press-fitting, or equivalent, so that an electrical or mechanical connect. This document applies to circuits with rated voltage AC not exceeding 1000V, frequency up to 1000Hz or DC not exceeding 1500V. PCB terminals for treated or untreated copper conductors with a connection cross-sectional area of 0.08mm2~300mm2 (AWG28/600kcmil) sub-row. Note 1.The large-section terminal block is specially used for specially designed high-current PCBs. Keep the cross-sectional area range up to 300mm2 to cover everything possible the use of. See Appendix C for examples of high-current PCBs and PCB terminal blocks. Note 2.AWG is the abbreviation of "American Wire Gauge"; 1kcmil=1000cmil=0.507mm2; 1cmil = 1 circular mil = area of a circle with a diameter of 1 mil; 1mil=1/1000 inch=0.0254mm. This document can be used as a special specification with components (isolating devices, integral tubular fuse-links and similar components or conductors with other dimensions, etc.) Guidelines for Type PCB Terminal Blocks. Where applicable, when referring to IEC 60947-1.2020, the term "clamp" is used in this document instead of "terminal".

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB/T 9789-2008 Sulfur dioxide corrosion test of metals and other inorganic coatings under normal condensation conditions (ISO 6988. 1985, IDT) IEC 60068-2-20 Environmental testing part 2-20.Test test T. Test for resistance to soldering heat and solderability of equipment with conductors Note. GB/T 2423.28-2005 Environmental Testing of Electrical and Electronic Products Part 2.Test Method Test T. Soldering (IEC 60068-2-20.1979, IDT) IEC 60352-1 Solderless connections part 1.General requirements, test methods and guidance for use of wrap-around connections (Solderlesscon- IEC 60352-2 Solderless connections Part 2.Crimp connections general requirements, test methods and guidelines for use (Solderlesscon- Note. GB/T 18290.2-2015 Solderless connections Part 2.General requirements, test methods and usage guidelines for crimp connections (IEC 60352-2. 2006, IDT) IEC 60352-3 Solderless connections Part 3.Accessible solderless insulation displacement connections General requirements, test methods and guidelines for use

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14048.22-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14048.22-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14048.22-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14048.22-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14048.22-2022?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14048.22-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.