|
US$519.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14048.13-2017: Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB) Status: Valid GB/T 14048.13: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14048.13-2017 | English | 519 |
Add to Cart
|
5 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
| Valid |
GB/T 14048.13-2017
|
| GB/T 14048.13-2006 | English | 919 |
Add to Cart
|
4 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDF)
| Obsolete |
GB/T 14048.13-2006
|
PDF similar to GB/T 14048.13-2017
Basic data | Standard ID | GB/T 14048.13-2017 (GB/T14048.13-2017) | | Description (Translated English) | Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB) | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K30 | | Classification of International Standard | 29.130.20 | | Word Count Estimation | 26,223 | | Date of Issue | 2017-09-29 | | Date of Implementation | 2018-04-01 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 14048.13-2017: Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear - Part 5-3. Control circuit devices and switching elements - Requirements for proximity devices with defined behavior under fault conditions (PDDB)
ICS 29.130.20
K30
National Standards of People's Republic of China
Replacing GB/T 14048.13-2006
Low-voltage switchgear and control equipment
Part 5-3. Control circuit devices and switching elements
In the fault conditions have a definite function
Proximity Switch (PDDB) requirements
Part 5-3.Controlcircuitdevicesandswitchingelements-
faultconditions (PDDB)
(IEC 60947-5-3.2013, IDT)
2017-09-29 Release.2018-04-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 General 1
2 Terms, definitions and abbreviations 2
3 Categories 8
4 Features 8
5 product information 8
6 normal use, installation and transportation conditions 9
7 Structure and performance requirements 9
8 Test 13
9 amendment 14
Appendix A (informative) Example of a simple control system complying with the IEC 61511 series of standards
References 19
Foreword
"Low-voltage switchgear and control equipment" consists of the following components.
--- Part 1. General principles;
--- Part 2. Circuit breakers;
--- Part 3. Switches, isolators, disconnectors and fuse combinations;
--- Part 4-1. Contactors and Motor Starters Electromechanical contactors and motor starters (including motor protectors);
--- Part 4-2. Contactors and Motor Starters Semiconductor Controllers and Starters for AC Motors (Including Soft Starters);
--- Part 4-3. Contactors and motor starters AC semiconductor controllers and contactors for non-motor loads;
--- Part 5-1. Control circuit devices and switching elements Electromechanical control circuit devices;
--- Part 5-2. Control circuit appliances and switching elements proximity switch;
--- Part 5-3. Control circuit devices and switching elements Proximity switch (PDDB) with defined function under fault conditions
Claim;
--- Part 5-4. Control circuit devices and switching elements small capacity contact performance evaluation method special test;
--- Part 5-5 part of the control circuit electrical and switching elements with electrical mechanical locking latch emergency braking device;
--- Part 5-6. DC link control circuit (NAMUR) for electrical and switching element proximity sensors and switching amplifiers;
--- Part 5-7. Control circuit devices and switching elements for analog devices with the analog output requirements;
--- Part 5-8. Control circuit electrical and switching elements three enable switch;
--- Part 5-9. Control circuit electrical and switching components flow switch;
--- Part 6-1. Multifunction electrical switch electrical appliances;
--- Part 6-2. Multifunction Electrical Equipment (Equipment) Control and Protection Switching Equipment (CPS);
--- Part 7-1. Auxiliary device copper conductor terminal block;
--- Part 7-2. Auxiliary device copper conductor protective conductor terminal block;
--- Part 7-3. Auxiliary fuses terminal block safety requirements;
--- Part 8. Rotating motor with thermal protection (PTC) control unit.
This section is "low-voltage switchgear and control equipment," Part 5-3.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 14048.13-2006 "Low-voltage switchgear and control equipment Part 5-3. Control circuit devices and switches
Elements with Proximity Switches (PDF) Requirements Under Fault Conditions ".
This section compared with GB/T 14048.13-2006 main technical changes are as follows.
--- Added terms and definitions related to failure, level of safety performance and structural limitations, etc., deleting terms related to integrated circuits;
--- Added functional safety related specifications and usage information, and added performance to PDDB's ECM compatibility requirements
Criteria and other aspects (see Chapter 7);
--- Deleted the control and monitoring device design requirements (see 7.1);
--- Deleted 8.7 "verification of determination of fault conditions" and 8.8 "Evaluation of programmable or composite integrated circuits" (see
8 chapters);
--- Added "amendment" chapter (see Chapter 9);
--- Standard full text is no longer related to integrated circuits and programming requirements, also deleted the original Appendix A "applied by the shadow of 8.7 and 8.8
LIST PDF Single Failure List of Electrical Equipment ", replace it with a new Appendix A (informative)" IEC 61511 compliant
Column standard simple control system example. "
This section uses the translation method identical with IEC 60947-5-3.2013 "low-voltage switchgear and control equipment Part 5-3. Control of electricity
Road electrical appliances and switching elements in the fault conditions have determined the function of the proximity switch (PDDB) requirements. "
The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
--- GB/T 14048.1-2012 low-voltage switchgear and control equipment Part 1. General (IEC 60947-1.2011,
MOD);
--- GB/T 14048.5-2008 Low-voltage switchgear and control equipment Part 5-1. Control circuit devices and switching elements
Electromechanical control circuit appliances (IEC 60947-5-1.2003, MOD);
Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2).
2001, IDT);
--- GB/T 17626.3-2006 Electromagnetic compatibility test and measurement techniques RF electromagnetic field radiation immunity test
(IEC 61000-4-3.2002, IDT);
--- GB/T 17626.4-2008 Electromagnetic compatibility test and measurement techniques Fast transient impulse group immunity test
(IEC 61000-4-4.2004, IDT);
--- GB/T 17626.6-2008 electromagnetic compatibility test and measurement techniques RF field induced conduction disturbances immunity
(IEC 61000-4-6.2006, IDT);
Electromagnetic compatibility (EMC) - Testing and measurement techniques - Power frequency magnetic field immunity test (IEC 61000-4-8).
2001, IDT);
--- GB/T 20438.1-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1. General
Seeking (IEC 61508-1.1998, IDT);
--- GB/T 20438.2-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2. Electrical /
Requirements for electronic/programmable electronic safety related systems (IEC 61508-2.2000, IDT);
--- GB/T 20438.3-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3. Software requirements
Seeking (IEC 61508-3.1998, IDT);
--- GB 28526-2012 Mechanical and Electrical Safety Safety Functional Safety of Electrical, Electronic and Programmable Electronic Control Systems
(IEC 62061.2005, IDT).
This part made the following editorial changes according to the specific conditions of our country.
--- Removed the terms and definitions of the index, and correction of article references the definition of article number.
--- Removed 2.2.28 Central Plains Note 2, its content is only related to the choice of words in other language versions of different, has nothing to do with our country.
This part is proposed by China Electrical Equipment Industry Association.
This part of the National Standardization Technical Committee of low-voltage electrical (SAC/TC189) centralized.
This section drafted unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Branch Electric Technology Co., Ltd., Zhejiang Chint Electric Co., Ltd.
The main drafters of this section. Zhang Lili, Li Hui, Zeng Ping, Jin Haisheng.
This part replaces the standards previously issued as.
--- GB/T 14048.13-2006.
Low-voltage switchgear and control equipment
Part 5-3. Control circuit devices and switching elements
In the fault conditions have a definite function
Proximity Switch (PDDB) requirements
1 General
1.1 Scope
This section of "Low-voltage switchgear and control equipment" is a supplement to GB/T 14048.10, provides a certain function of proximity to open
Off (PDDB) Performance requirements under fault conditions. This section does not specify any other features required for a particular purpose.
This section does not include proximity switches with analog output.
This section does not address specific noise-related requirements, because the control circuit electrical appliances and switching noise can be regarded as non-hazardous.
If the PDDB is used in some cases to meet the additional requirements specified in other standards, the requirements of the relevant standards apply.
Compliance with this section does not guarantee the safety-related specific features. Moreover, this section does not specify the behavior of the PDDB or for subtraction
Requirements for devices that interfere with each other, such as coded markings, with small switches. Therefore, in addition to the requirements of this section, the need to consider these and other needles
Requirements for a specific purpose.
Note 1. PDDB can also be used as an interlock (see ISO 14119) in view of its function under fault conditions.
Note 2. The IEC 61496 series of standards give the requirements for electro-sensitive protective equipment for personnel testing.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (IEC 60068-2-
1.2007, IDT)
GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Db alternating hot and humid (12h
12h cycle) (IEC 60068-2-30.2005, IDT)
GB/T 4208-2008 enclosure protection (IP code) (IEC 60529.1989 A1.1999, IDT)
GB/T 14048.10-2016 Low-voltage switchgear and control equipment Part 5-2. Control circuit appliances and switching elements close
Switch (IEC 60947-5-2.2007 A1.2012, IDT)
Safety of machinery - Part 1 of the safety control system for machinery - General principles of design (ISO 13849-1).
2006, IDT)
Electromagnetic compatibility (EMC) test and measurement techniques Surge (immunity) immunity test (IEC 61000-4-5).
2005, IDT)
GB/T 17626.11-2008 electromagnetic compatibility test and measurement techniques voltage dips, short interruptions and voltage variations immunity
Test (IEC 61000-4-11.2004, IDT)
IEC 60947-1-2007 low-voltage switchgear and control equipment Part 1. General (Low-voltagewitchgearandcon-
trolgear-Part 1.Generalrules)
IEC 60947-1.2007/A1.2010 No. 1 Amendment (Amendment1,2010)
IEC 60947-5-1-2003 Low-voltage switchgear and controlgear - Part 5-1 - Control circuits Electrical and switchgear electromechanical
|