US$454.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12164.3-2013: Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 12164.3-2013 | English | 454 |
Add to Cart
|
3 days [Need to translate]
|
Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence
| Valid |
GB/T 12164.3-2013
|
PDF similar to GB/T 12164.3-2013
Basic data | Standard ID | GB/T 12164.3-2013 (GB/T12164.3-2013) | | Description (Translated English) | Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F74 | | Classification of International Standard | 17.240 | | Word Count Estimation | 23,284 | | Quoted Standard | GB/T 12162.3-2004; GB/T 12164.1; GB/T 12164.3; ISO 6890-1; ISO 6890-2-2004 | | Adopted Standard | ISO 6980-3-2006.IDT | | Regulation (derived from) | National Standards Bulletin No. 21 of 2013 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the directional dose equivalent H according to "(0. 07, ��) and personal dose equivalent Hp (0. 07) to determine the calibration and radiation protection dose (rate) instrument response, and to determine the dose (rate) meter energy |
GB/T 12164.3-2013: Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Reference beta radiations Part 3.. Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence
ICS 17.240
F74
National Standards of People's Republic of China
β reference radiation - Part 3. Location and personal dose
Instrument calibration and energy response and angular response is determined
Referencebetaradiations-Part 3. Calibrationofareaandpersonaldosemeters
(ISO 6980-3.2006, IDT)
Issued on. 2013-10-10
2014-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 applies to all sites and personal dosimeters calibration procedure 7
5 special place dosimeter calibration procedure 10
6 personal dosimeter special calibration procedure 10
7 Expression of results 11
Appendix A (normative) Symbols and Abbreviations 13
Appendix B (normative) Reference conditions 15
Annex C (informative) Some β reference radiation field conversion coefficient of 17
References 19
Foreword
GB/T 12164 "β reference radiation" is divided into three parts.
--- Part 1. generating method;
--- Part 2. Characterization of the radiation field and a substantial amount of relevant calibration basis;
OK place and personal dosimeters calibrated response and its energy and angular response. Part --- 3.
This section GB/T Part of 312,164.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 6980-3.2006 "β reference particle radiation - Part 3. Location and personal dosimeter
Calibration and the energy and angular response is determined. "
Consistency correspondence with international standards in this standard references of the following documents.
--- GB/T 12164.1-2008 β reference radiation - Part 1. production method (ISO 6980-1.2006, IDT).
And ISO 6980-3.2006 as compared to, for ease of use, this section made the following editorial changes.
--- 4.1.1 change the title "Select Source" and cancel 4.1.1.1 title.
This part is proposed by the China National Nuclear Corporation.
This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized.
This section drafted by. China Institute of Atomic Energy.
The main drafters of this section. Wei Kexin, Wang Hongyu, Song Mingzhe, Yang Jing.
β reference radiation - Part 3. Location and personal dose
Instrument calibration and energy response and angular response is determined
1 Scope
Given radiation protection dose (rate) meter response, and determining the dose (rate) meter energy response and angular response methods.
This section applies to a calibration and determine the amount of practical ICRU radiation protection dose (rate) meter response.
This section does not apply to fixed place dosimeter field calibration.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference radiations 3
. Determination of the calibration response and energy and angular response of dosimeters and workplace personal dosimeter (ISO 4037-3.1999, IDT)
GB/T 12164 (all parts) β radiation reference
ISO 6980-1 nuclear β reference radiation particles - Part 1. production method (Nuclearenergy-Referencebeta-particle
radiation-Part 1. Methodsofproduction)
ISO 6980-2.2004 Nuclear β reference particle radiation - Part 2. Characterization of the radiation field and the fundamental basis of the amount of the relevant calibration
(Nuclearenergy-Referencebeta-particleradiation-Part 2. Calibrationfundamentalsrelatedtobasic
quantitiescharacterizingtheradiationfield)
No. ICRU51 Report. Quantities and units (Quantitiesandunitsinradiationprotection 1993 Radiation Protection Dosimetry
dosimetry)
International Basic and General Terms in Metrology (VIM), BIPM/IEC /International Federation of Clinical Chemistry/International Standard
Organization for Standardization/International Union of Pure and applied chemistry/International Union of Pure and Applied Physics/international legal metrology organizations [International
vocabularyofbasicandgeneraltermsinmetrology (VIM), BIPM/IEC /IFCC/ISO /IUPAC/IUPAP /
OIML]
3 Terms and Definitions
No. ICRU51 and the following terms and definitions are defined reports and VIM apply to this document.
3.1
ICRU tissue ICRUtissue
Density of material 1g · cm-3, the quality of the group is divided into. O. 76.2%; H. 10.1%; C. 11.1%; N. 2.6%.
Note. See report No. ICRU39.
3.2
Β largest energy maximumbetaenergy
Emax
One or several specific β particle-emitting nuclide in a continuous spectrum of maximum energy.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12164.3-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 12164.3-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 12164.3-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12164.3-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|