US$1859.00 · In stock Delivery: <= 13 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 50029-2014: Code for design of compressed air station Status: Valid GB 50029: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 50029-2014 | English | 1859 |
Add to Cart
|
13 days [Need to translate]
|
Code for design of compressed air station
| Valid |
GB 50029-2014
|
| GB 50029-2003 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Code for design of compressed air station
| Obsolete |
GB 50029-2003
|
PDF similar to GB 50029-2014
Basic data | Standard ID | GB 50029-2014 (GB50029-2014) | | Description (Translated English) | Code for design of compressed air station | | Sector / Industry | National Standard | | Classification of Chinese Standard | P47 | | Classification of International Standard | 91.140.01 | | Word Count Estimation | 84,854 | | Date of Issue | 1/9/2014 | | Date of Implementation | 8/1/2014 | | Older Standard (superseded by this standard) | GB 50029-2003 | | Quoted Standard | GB 50050; GB 50052; GB 50055; GB 50073; GB/T 50087; GB 50187; GB 3096 | | Regulation (derived from) | Ministry of Housing and Urban-Rural Development Bulletin No. 296 | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China; General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China | | Summary | This Standard specifies equipped with electric drive, the working pressure is less than or equal to the piston air compressors, diaphragm air compressor, screw air compressors, centrifugal air compressor new, renovation, expansion of compressed air statio |
UDC
NATIONAL STANDARD
OF THE .PEOPLE'S REPUBLIC OF CHINA
Code for design of compressed air station
Date of issuing. AprillS, 2003 Date of enforcement. June 1, 2003
Jointly issued by. General Administration of Quality Supervmon, Inspection and
Quarantine of the People's Republic of China
M.inNiy of Construction of the People's Republic of China
NATIONAL STANDARD OF
THE PEOPLE'S REPUBLIC OF CHINA
Code for design of compressed air station
Chief Edition Department. China Machinery Industry Federati on
Approved by. Mi ni stry of Constniction of the Peop le 's Republic of China
Implementation date. June 1, 2003
Beijing 2003
NOTICE
This code is written in Chinese and English . The Chinese text shall be taken as the ruling one
in the event of any inconsistency between the Chinese text and the English text.
Proclamation by Ministry of Construction
of the People's Republic of China
No. 139
Proclamation on the national standard pub li shing of Code for Des ign of Compressed Air
Station . Code for Design of Compressed A ir Station, in number of GB 50029-2003, is hereby
approved to be a national standard and executed from June 1, 2003 . Clause 3.0.6, 3.0.11, 3.0.12,
3.0.14, 4.0.7(2)(4), 4.0 .1 2, 6.0.3 , 6.0.8 and 6.0.9 are compulsory clauses and should be strictly
executed. At meanwhile, the former Code for Design of Compressed Air Station GBJ29-90 is
avoided.
China Planning Press publishes this code under the organization of Standard Norm Study
Station of Ministry of Construction.
Ministry of Construction of the People's Republic of China
April15, 2003
Forewords
To meet the requirement from Jianbiao [ 1997] No. I 08 Writ issued by the Ministry of
Construction, the revised Code is achieved base on Code for Design of Compressed Air Station GBJ
29-90 by China Machinery lntemational Engineering Design and Research Institute (the eighth Study
Institute of former the Ministry of Machinety Industry) together with other departments.
During the revis ion, after widely investigation and shtdy, careful conclusion was made on
experience respect of design and app lication since the former Code was executed. Related domestic
and abroad infonnation were refetTed, in addition with necessmy tests. After auditing and finalizing,
the Ministty of Construction in No. 139 Proclamation publishes the Code for execution.
The code is divided into nine chapters with six attachments. Revis ion is major on. a clause on
centrifugal air compressor is added. former contents on helical-lobe compressor,
drying/purification of compressed air, environment protection, energy-saving, safety in product ion
and labor protection were revised or added.
All of the clauses in black in the code are obligatory ones and should be strictly executed.
Obligatory clauses in the code are response for explanation by the Ministry of Construction while
China Machinery Intemational Engineering Design and Research Institute in charge specific
technical contents. During future execution of the code, we will be pleased to accept careful
experience conclusion in conjunction with engineering practice. Any opinion and suggestion can
be post to China Machinery International Engineering Design and Research Institute (Address.
No.18, Shaoshanzhonglu, Changsha City; Post code. 41 0007; Fax. 073 1-555191 4) for reference
in further revision.
The organization department, chief edition depatiment, deputy chief edition department, joint
departments , assistant departments and main drafter are as follows.
Organization depa1iment. China Machinery Industry Investigation and Design Association
Chief edition depatiment. China Machinery International Engineering Design and Research
Institute (the eighth Study Institute of former the Ministry of Machinery Industry)
Deputy chief edition department. Wuxi Compressor Co. , Ltd.
Joint edition depatiments.
Hunan Metallurgical Planning and Design Institute
The Third Design and Study Institute of the Ministry of Machinery Industry
The Foutih Design and Study Institute of the Ministry of Machinery Industry
China Machinery International Engineering Consulting and Design Institute
China Aviation Industry Planning, Design and Study Institute
Middle-South Power Design Institute of State Power Corporation
Assistant Depatiments.
Guangdong Zhaoqing Global Purification Equipment Co., Ltd.
Xi 'an Union Super-Filtering and Purifi£ation Equipment Co. , Ltd.
Fusheng Industrial (Shanghai) Co., Ltd.
Hangzhou Hanye Air Resource Purification Equipment Co., Ltd.
Hangzhou Jiamei Purification Equipment Co ., Ltd.
Main drafters. Wang Xuanhe Peng Heng Li Hongmei X v Hui I Li Debinl
Qiu Baoan Tian Hongbin Yang Kai Wang Dong Niu Yuren
jHan Jialon~ Hu Duowen
Contents
General ... I
2 Layout of compressed air station ... 2
3 Process systems ... 3
4 Ingredient and equipment layout of compressed air station ... 5
S Civi l works ... 7
6 Electrical, thermodynamic measurement instrument and protection dev ice ... 8
7 Water supp ly and sewerage ... 9
8 Heating and ventilation ... 10
9 Co1npressed air pipe ... 11
Appendix A The using of thermodynamic measurement instrument in piston air compressor
station ... 13
Appendix B The using of thermodynamic measurement instrument in helical-lobe air
compressor station ... 14
Appendix C The using of thermodynamic measurement instrument in centrifugal air compressor
station ... 15
Appendix D The using of thermodynamic alarming signal and self-protection device in piston
air compressor station ... 16
Appendix E The using of thennodynamic alarming signal and self-protection device in
helical-lobe air compressor stat ion ... 17
Appendix F The using of thennodynamic alarming signal and self-protection device in
centrifugal air compressor station ... 18
Wording explanation for the code ... 19
Descriptive provision ... _ ... 2 1
1 General
1.0.1 This code is revised for safety production, environment protection, energy saving, laboring
conditions improving, technical advancing and economic in compressed air stat ion design.
1.0.2 This code can be applied to the new-building, reconstruction or expansion of compressed
air station and pipe for both piston air compressor and helical-lobe air compressor which operate
pressure is less or equals to 1.25 MPa (gauge pressure), or centrifugal air compressor which is less
or equals to 500 m3/min (unit air displacement).
This code cannot be applied to the design for compressed air station and pipe at underground
we ll , cave and any other special locations .
1.0.3 Except E grade for compressed air station with cylinder oil-free lubricati on piston air
compressor and non-oil spraying helical-lobe air compressor, fire hazard danger class for any
other compressed air stations are all D grade.
1.0.4 Former building, equipment and pipe should be fully uti lized during design of
reconstruction and expansion of compressed air station and pipe.
1.0.5 Beside this code, any current national provision on obligatory standard should be followed
in design of compressed air station and pipe.
2 Layout of compressed air station
2.0.1 The following factors and technical-economic comparison shou ld be concerned for layout
of compressed air station inside facto ry (or ore).
1 Nearby compressed air using and loading center;
2 Reasonable in power and water supply;
3 Reserves possibility for further expansion;
4 Away from location at which explosive or corrosive gas and dust are formed , and the
place, which has the least probability to be down-wind direction annually.
5 The distance between compressed air station and location where protection against noise
and vibration is required should meet provisions in current national related standards.
2.0.2 Building orientation of compressed air station should be favorable to nature ventilation in
equipments and under less west sunshine.
2.0.3 Isolate building should be adopted for compressed air station where a piston air
compressor, centrifugal air compressor, or helical-lobe air compressor which unit air displacement
is less or equals to 20m3/minis installed.
If compressed air station is connected or inside another building, walls for isolating are
required. Layout of compressor should locate nearby exterior wall. In a multiple-story building it
should be at the bottom st...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 50029-2014_English be delivered?Answer: Upon your order, we will start to translate GB 50029-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 9 ~ 13 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 50029-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB 50029-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 50029-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 50029-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|