GB 4706.109-2013English254 Add to Cart Days<=3 Household and similar electrical appliances. Safety. Particular requirements for electrolysers Valid GB 4706.109-2013
GB 4706.109-2013Chinese18 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

 GB 4706.109-2013 -- Click to view a PDF  
Detail Information of GB 4706.109-2013; GB4706.109-2013
Description (Translated English): Household and similar electrical appliances. Safety. Particular requirements for electrolysers
Sector / Industry: National Standard
Classification of Chinese Standard: K09
Classification of International Standard: 13.260
Word Count Estimation: 15,168
Quoted Standard: GB 4706.1-2005; GB/T 2423.18-2000; ISO 1817-2005; IEC 60079-15-2001
Adopted Standard: IEC 60335-2-108-2008, IDT
Drafting Organization: China Household Electrical Appliances Research Institute
Administrative Organization: National Standardization Technical Committee appliances wood
Regulation (derived from): National Standards Bulletin 2013 No. 27
Proposing organization: China Light Industry Association
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to household appliances and similar purposes, the washing water electrolysis can produce as a low-viscosity liquid detergent ionization, rated voltage not exceeding 250V electrolyzer safety. Under the most adverse conditions that may


GB 4706.109-2013
Household and similar electrical appliances.Safety.Particular requirements for electrolysers
ICS 13.260
K09
National Standards of People's Republic of China
Household and similar electrical appliances - Safety
The special requirements of the electrolyzer
Householdandsimilarelectricalappliances-Safety-
Particularrequirementsforelectrolysers
(IEC 60335-2-108:2008, IDT)
Published 2013-12-31
2015-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative References 1
Terms and definitions 1 3
4 General requirements 2
General conditions for 5 tests 2
6 Category 2
7 Marking and instructions 2
8 Protection against touching live parts of 2
Start electric appliance 3 9
10 Power input and current 3
11 heat 3
12 Void 3
Leakage current and electric strength at the operating temperature of 13 3
14 Transient overvoltages 3
3 15 Moisture resistance
16 Leakage current and electric strength 3
Transformer 17 and associated circuitry overload 3
18 Endurance 3
19 Abnormal operation 4
20 Stability and mechanical hazards 4
4 21 Mechanical strength
Structure 22 4
Internal wiring 23 5
5 element 24
25 and the external power connection cord 5
26 with the external lead terminals 5
27 earthing 5
Screw connection 5 and 28
Clearances 29, creepage distances and solid insulation 5
30 and fire resistant 5
5 31 rust
32 radiation, toxicity and similar hazards 6
Appendix 7
Aging test Annex AA (normative) synthetic rubber member 7
Additional requirements guide Annex BB (informative) with a standard electrolytic cell appliance is determined conclusions 8
Reference 9
Foreword
All technical contents of this section is mandatory.
GB 4706 "Household and similar electrical appliances" made up of several parts.
--- Part 1: General requirements;
--- other part of the special requirements.
This section is part of the 109 GB 4706.
This section drafted in accordance with the rules GB/T 1.1 is given.
This section should GB 4706.1-2005: with "safe 1 Household and similar electrical appliances General requirements."
This section uses the translation method is equivalent to using 60335-2-108 IEC :2008 "Household and Similar Electrical Appliances - Safety - section 2-108
Min: Special requirements "of the cell.
Consistency correspondence relationship with international documents in this section of our normative references the following documents:
--- GB/T 1690-2010 Rubber, vulcanized or thermoplastic liquid resistant test methods (ISO 1817:2005, MOD)
--- GB 3836.8-2003 Electrical Apparatus for Explosive Gas Atmospheres Part 8: "n" electrical equipment (IEC 60079-15:
2001, MOD)
This part of the editorial changes.
This section was proposed by China Light Industry Federation.
This part of the jurisdiction of the National Standardization Technical Committee appliances (SAC/TC46).
This part of the main drafting units: China Household Electrical Appliances Research Institute, Hefei Rongshida Sanyo Electric Co., Ltd., Hangzhou Lin electronic God has
Limited, Ningbo Xinle Household Appliances Co., Ltd., Matsushita Home Appliances Research and Development (Hangzhou) Co., Ltd., Shanghai Entry-Exit Inspection and Quarantine Bureau and electronic products
Testing Center, Guangzhou CVC Technology Limited.
The main drafters of this section: Zhu Yan, Jin Youhua, Wang Hua, Liu Min, Wu Qin strong, Guchun Geng, Zhang Jia new, Chen Cankun.
introduction
This portion is recognized for household electrical appliances and similar requirements according to the manufacturer instructions and used under normal conditions, is of
With an acceptable level of risk international protection of electrical, mechanical, thermal, radiation and fire, it also includes the possible use of expected
Abnormal circumstances, and taking into account electromagnetic interference affects the way for the safe operation of the appliance.
In developing this part has been as much as possible into account the requirements of IEC 60364 in order to make electrical appliances when connecting to the grid
Gas wiring rules requires coordinated. But electrical wiring rules may be different for each country.
If a number of functions related to the special requirements of the appliance IEC 60335 series of different parts, as far as is reasonable in the circumstances
Under the special requirements of the relevant standards should be applied to each function separately. If applicable, taking into account the impact of this function to other functions.
Note 1: refers to the technical committee responsible for determining the criteria to determine the appliance in Part 2, other than appliances involving general requirements, no special requirements of the problem.
When the special requirements not included in Part 1 of the appended claims when hazardous, Part 1 applies.
Note 2: refers to when the IEC 60335 series of standards has been considered dangerous instrument development process encountered dangerous situations involving other than the standard does not apply, for example,
The surface temperature of many appliances, for example, ISO 13732-1 claim hot surface, do not apply to the first or the second part of the standard.
If the test has found damage to other standard safety features principle, it is considered that the appliance does not meet the requirements of this section.
Material or appliance use a structure other than the requirements of this, the product may be intended in this section to these requirements
Inspection and testing. If found to be substantially equivalent, it can be determined which comply with this part.
For the electrolytic cell, according to the present selection test section, and does not require the machine to be tested as a prerequisite. For example reference
IEC 60335 Part 2 of Chapter 24, however, comply with this part if the cell is mounted on the appliance, the appliance of the relevant test
Test may be suitably reduced if there is, comprising a control system or the protection system shall comply with this part.
In particular, the structure can be carefully examined and tested separately in different cell, and therefore, when the electrolytic cell used in different appliances
When, inspection and tests required may be correspondingly omitted.
Household and similar electrical appliances - Safety
The special requirements of the electrolyzer
1 Scope
This chapter in GB 4706.1-2005 replaced by the following.
This section applies to household appliances and similar uses, washed with water electrolysis can produce a low viscosity liquid detergent ionization rated
Voltage not exceeding 250V safety of the cell. Under the most adverse conditions that may arise in the normal use of the cell tested separately.
101 Note: Examples may include cell appliance:
--- washing machine (GB 4706.24);
--- dishwasher (GB 4706.25);
--- electrolytic water for sanitary purposes appliance.
102 Note: This section is not replaced with the special requirements of the relevant part of the appliance electrolytic cell, however, in line with this part of the electrolytic cell, a special tool is not necessary to
Determine the correlation tests of the whole or parts. If the control system is connected with the electrolytic cell and the appliance control system needs to be performed on the final product
Additional tests, additional requirements guide appliance with the standard cell of the determination is given in Appendix conclusion of BB.
103 Note: The following facts should attract attention:
--- for use on a vehicle, ship or aircraft, appliances, additional requirements may be necessary;
--- the national health authorities, the national labor protection authorities, the national water supply authorities and similar authorities of the appliance provides additional
Claim.
104 NOTE: This does not apply to:
--- designed specifically for industrial use appliances;
--- used in special circumstances appliance, or explosive gases, for example corrosive gases (dust, vapor or gas) environment.
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper
Pieces, undated references, the latest edition (including any amendments) applies to this document.
GB 4706.1-2005 in the content except as follows, are applicable.
increase:
GB/T 2423.18-2000 Environmental testing for electric and electronic products - Part 2: Test Method Test Kb: Salt mist, cyclic (chloride
Sodium) (IEC 60068-2-52:1996, IDT)
ISO 1817:2005 Rubber, vulcanized or thermoplastic liquid resistance test method (Rubbervulcanized-Determination
oftheeffectofliquids)
IEC 60079-15:2001 Explosive Gas Atmospheres electrical equipment - Part 8: "n" electrical equipment (Electrical
apparatusforexplosivegasatmospheres-Part 15: Construction, testandmarkingoftypeofprotec-
tion, "n" electricalapparatus)
3 Terms and Definitions
The following terms and definitions apply to this document.
GB 4706.1-2005 in the content except as follows, are applicable.
3.1.9 Replacement:
Work normaloperation
Electrolyzer operating under the following conditions:
If the water electrolyzer by a user, and the type of water injection should conform to the specification requirements using the electrolytic cell.
Maintained in the range 10 ℃ ~ 25 ℃ electrolytic bath water temperature.
3.101
Cell electrolyser
Generating the wash water electrolysis means.
4 General requirements
GB 4706.1-2005 in this chapter apply.
General conditions for 5 tests
GB 4706.1-2005 in the content except as follows, are applicable.
5.101 electrolyzer tested as motor-operated appliances.
Category 6
GB 4706.1-2005 in the content except as follows, are applicable.
modify:
Cell should class Ⅰ, Ⅱ class or class Ⅲ appliance; if rated voltage not exceeding 150V, may be a Class 0 appliances.
6.101 electrolyzer is divided into:
--- cell terminals intended to be connected directly to the appliance power cord; or
--- not intended cell terminal directly connected to the appliance power cord.
Note 1: In the above two types, the cell may be supplied with or without a power cord in the delivery process;
Note 2: For the cell terminals can be connected directly to the power cord of the appliance, or may not by power cord, connected directly to the appliance terminal.
Compliance is checked by inspection and relevant tests.
7 Marking and instructions
GB 4706.1-2005 in the content except as follows, are applicable.
7.1 Review:
Rated input power or current need not identify.
7.5 Not applicable.
7.7 Not applicable.
7.12 instead of:
Instruction should contain the cell volume for containing and detailed description, and detailed description of the chemical reaction.
Note: Details of electrolyte used, e.g., common name or manufacturer part number of the electrolytic solution.
8 Protection against access to live parts
GB 4706.1-2005 in this chapter apply.
9 start electric appliances
GB 4706.1-2005 in this chapter does not apply.
Power input and current 10
GB 4706.1-2005 in this chapter does not apply.
11 fever
GB 4706.1-2005 in the content except as follows, are applicable.
11.7 Replacement:
Electrolyzer runs to steady conditions are established.
12 Void
Leakage current and electric strength at the operating temperature of 13
GB 4706.1-2005 in this chapter apply.
14 transient overvoltage
GB 4706.1-2005 in this chapter apply.
15 Moisture resistance
GB 4706.1-2005 in this chapter apply.
16 Leakage current and electric strength
GB 4706.1-2005 in this chapter apply.
Overload protection of transformers and associated circuitry 17
GB 4706.1-2005 in this chapter apply.
18 Endurance
GB 4706.1-2005 in this chapter does not apply.
19 Abnormal operation
GB 4706.1-2005 in this chapter apply.
20 Stability and mechanical hazards
GB 4706.1-2005 in this chapter apply.
21 Mechanical strength
GB 4706.1-2005 in this chapter apply.
22 Construction
GB 4706.1-2005 in the content except as follows, are applicable.
22.6 increase:
Synthetic rubber member should be able to withstand aging test specified in Annex AA, during the test should be a leak phenomenon.
modify:
Washed with water electrolyzer made colored solution instead of colored water.
22.101 in the cell structure should have a diameter of at least 5mm or width of at least 3mm, the area of not less than 20mm2, and maintained
The atmosphere communication hole. The holes should be provided not blocked in normal use position.
Determining whether checked by inspection and measurement.
Following regions during normal use, the cell chemical reaction to produce hydrogen and 22.102 not reached a dangerous level:
--- generating electrical arcing or sparking element mounting portion used in the normal or abnormal, unless these components by IEC 60079-
15: Test 2001ⅡC based gas; or
--- containing hydrogen release can be exposed, and the surface normal or abnormal use of temperatures in excess of 460 ℃ member.
By visual inspection and measurement of surface temperature and corresponding normal non-normal use, and the following tests:
A cell cycle in a normal running state of use.
From the start of the test until the end of the hydrogen concentration of the relevant parts of the continuous measurement, using the measured during the test to obtain the maximum concentration of hydrogen minus
Previously measured background concentration.
Value shall exceed the flammable lower limit of hydrogen (the LFL) of 50%.
Note 1: LFL of 4% hydrogen (by volume);
Note 2: The gas concentration detection apparatus for use, for example by using infrared sensor technology, having a fast response speed, typically 2s or 3s, but the degree of influence and
test results;
NOTE 3: If a gas chromatograph, the sample should be in a defined area 2mL, taken once every 30s;
Note 4: The test results do not rule out the use does not cause undue influence of other instruments.
22.103 electrolyzer when in normal use, it should not cause a chemical reaction due to variations in the pH of the wash water and corrosive.
By GB T 2423.18-2000Kb severities salt spray test to determine the level of 2/eligibility. If the pH is higher than
Predetermined value GB/T 2423.18-2000, the pH of the test solution should be equal to about the pH of the wash water in normal use.
Before the test, applying a hard shell coating is scratched with a needle on the surface thereof, the end portion of the needle 40 ° conical tip circle radius is
0.25mm ± 0.02mm. Needle holder in the horizontal plane 80 ° ~ 85 °, an axial force is applied 10N ± 0.5N's. Needle along the insulating surface
Rate of about 20mm/s gliding, rubs five times a length of at least 5mm, 5mm away from the position of the edge.
After the test, there should be no cell phenomenon does not comply with the requirements of this occurrence, especially not in line with Chapter 8 and Chapter 27 of the
Damaged, the coating should crack and peeling.
Internal wiring 23
GB 4706.1-2005 in this chapter apply.
Element 24
GB 4706.1-2005 in this chapter apply.
25 and the external power connection cord
GB 4706.1-2005 in this chapter apply.
External terminal conductors 26
GB 4706.1-2005 in this chapter apply.
27 earthing
GB 4706.1-2005 in this chapter apply.
28 and screw connection
GB 4706.1-2005 in this chapter apply.
Clearances 29, creepage distances and solid insulation
GB 4706.1-2005 in the content except as follows, are applicable.
29.2 Replacement:
The use of the electrolytic solution, micro-environment pollution level 3, and CTI value of the insulation should be not less than 250, unless the insulating package, or
In normal use position so that the insulation in the electrolytic cell is exposed to possible contamination of the environment.
30 Resistance to heat and fire
GB 4706.1-2005 in the content except as follows, are applicable.
30.2.2 Not applicable.
31 rust
GB 4706.1-2005 in this chapter apply.
32 radiation, toxicity and similar hazards
GB 4706.1-2005 in addition to the following contents of the chapter, are applicable.
increase:
Cell chemical reaction of ozone concentration should not be too large.
By the following tests, to determine eligibility:
In a closed test room, the room size is 2.5m × 3.5m × 3.0m, polyethylene sheet covering the wall surface.
Room maintained at about 25 ℃, a relative humidity of about 50%. Manual cell according to claim running under normal operating conditions of a
cycle.
22.101 ozone sampling locations should be in a predetermined position of the outer outlet holes of 10mm, to measure the background ozone concentration at start of test, then
The background concentration of the test the maximum ozone concentration measured is subtracted.
The percentage of ozone concentration should not exceed 5 × 10-6.
appendix
GB 4706.1-2005 in the content except as follows, are applicable.
Appendix AA
(Normative)
Synthetic rubber member aging test
Synthetic rubber component aging test, the sample was immersed in high temperature solution was washed with a solution made of an electrolytic cell, measured prior to immersion, the test
Hardness and volume change test sample.
Each member with at least three test samples, the test samples and procedures in accordance with ISO 1817:2005 requirements, and the following modifications.
Test liquid 4
Test solution used in line with the electrolyte Chapter 11 test conditions.
Per liter of solution immersion test specimens does not exceed the total mass of 100g, to be completely immersed in the test specimens, and the entire submerged surface free
In solution. During the test, the test specimens should not be exposed directly to sunlight. Test specimens of different compounds can not be immersed in the same
Solution.
Test specimens 5
5.4 Pretreatment of the test specimens
Temperature of 23 ℃ ± 2 ℃, relative humidity of 50% ± 5%.
6 is immersed in the test solution
6.1 Temperature
After the test specimens was immersed, the solution was heated 1h to 75 ℃ ~ 80 ℃, and kept at this temperature, the solution was replaced every 24h, in the same manner
Heating.
Note: To prevent excessive evaporation of the solution, or the like recommended update sealing system solution used.
6.2 Duration
Test specimens of the total soaking time period is 48h ~ 49h.
After the test specimens to the immediately immersed in the solution held in the new ambient temperature, the specimens soaked 45min ± 15min.
After the sample block is removed, with water 15 ℃ ± 5 ℃ test specimens rinsed, and then dried with blotting paper.
7 program
Volume Change 7.2
Volume of test specimens should not exceed 10% of the increase in the measured value before immersion.
7.6 hardness change
Microhardness test applies.
The hardness change test specimens should not exceed 8IRHD, the surface is not sticky strain, cracking, or other damage can be seen depending on the subject should not appear.
Appendix BB
(Informative)
Additional requirements guide appliance with a standard electrolytic cell is determined conclusions
The following information is given for an end product standards detailed in the electrolytic cell with:
--- Manual should include a method to avoid clogging the pores in the cell in use;
--- 22.17 adapted to prevent clogging of the pores of the cell from the limit means during use;
--- 22.102 is suitable for checking the end product, check key parts of hydrogen accumulation;
--- 22.103 is suitable for checking the end product, check the key components of the electrolysis of water should not cause corrosion.
references
GB 4706.1-2005 in the content except as follows, are applicable.
increase:
[1] GB 4706.24 Particular requirements for washing machines and similar household electrical appliances
[2] GB 4706.25 Particular requirements for dishwashers and similar household electrical appliances
[3] Evaluation method of reacting human ergonomics ISO 13732-1 thermal environment in contact with the surface of the Part 1: the heating table
Surface (Ergonomicsofthethermalenvironment-Methodsfortheassessmentofhumanresponsestocon-
tactwithsurfaces-Part 1: Hotsurfaces)
Related standard:   GB 4706.107-2012  GB 4706.108-2012
   
 