US$369.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 3883.16-2008: [GB/T 3883.16-2008] Safety of hand-held motor-operated electric tools -- Part 2: Particular requirements for tackers Status: Valid GB 3883.16: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB 3883.16-2008 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
[GB/T 3883.16-2008] Safety of hand-held motor-operated electric tools -- Part 2: Particular requirements for tackers
| Valid |
GB 3883.16-2008
|
GB 3883.16-1993 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Safety of handheld motor operated electric tools. Part 2: Particular requirements for tackers
| Obsolete |
GB 3883.16-1993
|
PDF similar to GB 3883.16-2008
Basic data Standard ID | GB 3883.16-2008 (GB3883.16-2008) | Description (Translated English) | [GB/T 3883.16-2008] Safety of hand-held motor-operated electric tools -- Part 2: Particular requirements for tackers | Sector / Industry | National Standard | Classification of Chinese Standard | K64 | Classification of International Standard | 25.140.20 | Word Count Estimation | 14,111 | Date of Issue | 2008-03-24 | Date of Implementation | 2009-01-01 | Older Standard (superseded by this standard) | GB 3883.16-1993 | Quoted Standard | GB 3883.1 | Adopted Standard | IEC 60745-2-16-2008 Ed.2, ??IDT | Regulation (derived from) | Announcement of Newly Approved National Standards No. 5, 2008 (No. 118 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This Chinese standard applies to general purpose nail dryer. This standard does not apply to industrial products, equipment nail dryer. |
GB 3883.16-2008: [GB/T 3883.16-2008] Safety of hand-held motor-operated electric tools -- Part 2: Particular requirements for tackers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of hand-held motor-operated electric tools.Part 2. Particular requirements for tackers
ICS 25.140.20
K64
National Standards of People's Republic of China
GB 3883.16-2008/IEC 60745-2-16.2008
Replacing GB 3883.16-1993
Safety of hand-held power tools
Tackers requirements for. a second portion
(IEC 60745-2-16.2008Ed.2, IDT)
Published 2008-03-24
2009-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative References 1
3 Definitions 1
4 General requirements 2
General requirements of Test 2 5
6 Void 2
7 Category 2
8 signs and instructions 2
Protection against touching live parts 9 3
10 is started 3
11 Power input and current 3
12 heat 3
Leakage current 13 3
14 moisture resistance 3
15 3 Electric strength
16 and its associated circuitry to the transformer overload 4
17 Endurance 4
18 is not operating properly 4
19 mechanical hazards 4
5 20 Mechanical strength
21 Structure 5
5 internal wiring 22
5 23 components
Power source 24 and the coupling extension cord 5
Terminal 25 of the outer lead 5
5 grounding device 26
The coupling member 5 and the screw 27
28 creepage distance and clearance distance through insulation 5
29 in heat resistance, flame retardancy and resistance to tracking 6
30 rust 6
31 radiation, toxicity and similar hazards 6
Appendix 7
Reference 8
GB 3883.16-2008/IEC 60745-2-16.2008
Foreword
All technical contents of this section is mandatory.
GB 3883 "Safety of hand-held electric tools" are safety standards for hand-held power tool, the first part of the general requirements and
Requirements for the composition of two parts. GB 3883 structure and names are as follows.
GB 3883.1 "The first part of the security hand-held power tools. General requirements"
GB 3883.2 "safe hand-held electric tools Part II. screwdrivers and impact wrenches."
GB 3883.3 "Safety handheld power tool of the second part. grinders, polishers and disc sanders requirements"
GB 3883.4 "Safety handheld power tool of the second part. non-disc sander and polisher requirements for"
GB 3883.5 "The second part of the security hand-held power tools. circular saws"
GB 3883.6 "safe hand-held electric tools Part II. drills and impact drills requirements"
GB 3883.7 "secure a second portion of the hand-held power tool. hammer requires special tools"
GB 3883.8 "safe hand-held electric tools Part II. Particular requirements for electric shears and of"
GB 3883.9 "safe hand-held electric tools Part II. Particular requirements for tappers"
GB 3883.10 "safe hand-held electric tools Part II. Particular requirements for planers"
GB 3883.11 "Safety handheld power tool of the second part. reciprocating saws (jig, saber saws) special requirements"
GB 3883.12 "safe hand-held electric tools Part II. Particular requirements for concrete vibrators"
GB 3883.13 "the second part of the security hand-held power tools. non-flammable liquid spray guns for special requirements"
GB 3883.14 "the second part of the security hand-held power tools. Particular requirements for chain saws."
GB 3883.15 "the second part of the security hand-held power tools. pruning shears requirements"
GB 3883.16 "safe hand-held electric tools Part II. Particular requirements for tackers"
GB 3883.17 "safe hand-held electric tools Part II. routers and trimmers special requirements"
GB 3883.18 "the second part of the security hand-held power tools. electric marble cutters special requirements"
GB 3883.19 "Safety handheld power tool of the second part. the requirements for drain cleaners"
GB 3883.20 "the second part of the security hand-held power tools. band saws"
GB 3883.21 "the second part of the security hand-held power tools. requirements for strapping"
This request for a dedicated portion of the nailing machine, must IEC 60745-12003 (3.2 Version) "handheld power tool with equivalent
Safety Part 1. General requirements "established by GB 3883.1-2005" The first part of the security hand-held power tools. General requirements "
use together.
This section identical with IEC 60745-2-16.2008 (version 2.0), "the second part of the security hand-held power tools. Designed for tackers
With requirements ", the date of the present embodiment partially replace GB 3883.16-1993.
This standard and GB 3883.16-1993 main changes compared to the following.
1) Chapter 1 of Scope 1.1 Change. This section applies to the general-purpose nailing machine. This section does not apply to industrial products Equipment
The nailing machine.
2) defined in Chapter 3 2.2.23 deleting the original definition of normal load, increase nailing machine, operation system, a single sequence actuator, actuator ordered, without
Sequence actuator, actuator selectivity, self-resetting actuator, actuator, operation of the controller, the workpiece contact definitions.
3) the original Chapter 4, "General Considerations test" to Chapter 5, "General requirements for testing" and add 5.101.
4) The Chapter 7, "flag" was changed to Chapter 8, "and the specification flag"; 7.1 modify omitted is loaded in the first portion of input rated
Power or current, every minute or the maximum number of second flag operation; 7.13 delete the original increase, while the increase for the first portion 8.12.1
Was added, and increasing the safety of the nailing machine 8.12.101 specification; for 8.12.2b) increased 101) to 105).
GB 3883.16-2008/IEC 60745-2-16.2008
5) the original 11.4 "tool is run according to the provisions of the normal load, run equal to the rated operating time, in the absence of related marks, run
30min. Measuring the temperature rise "at the end of the run, the change in content of 12.2.
6) modifying the original 16.2, "is changed to the first paragraph. Tool predetermined normal load, but not installed fastener to 1.1 times the rated voltage intermittently transported
Line 24h, and then to 0.9 times the rated voltage intermittent operation 24h ", replace the contents of change of 17.2.
7) increase the content change of 18.12.
8) 18.1 additional original "nailing machine should start to avoid inadvertent engagement member may be emitted continuously, or for penetration of mass greater than 3g
25mm length greater than the nailing machine using the engaging member should be designed to. predict the manufacturer if any engagement member away from the tool
Incident at the air velocity is greater than or equal to 15m/s, then the maximum unless the tool to a maximum of 1.25 times the mass or mass tools
Plus the force of 5N (whichever is greater) of the tool is pressed against the workpiece or the tool can not run ", with this section 19.101
19.105 to be replaced.
9) the original 21.18.1 been modified.
10) The first part, the normative K "tool battery and battery box", Appendix L "to provide non-isolated power source coupled
Tool battery and the battery pack "as the appendix section.
This section states that "suitable", showing the corresponding provisions applicable in GB 3883.1-2005; stated in this section, "Change", and should
In this section prevail provisions; stated in this section, "Edit", and indicates the corresponding provision of GB 3883.1-2005 content should be present
After some changes the contents of the subject, and the provision of other content still apply; this states "addition", expressed in addition to compliance with GB 3883.1-
Outside the corresponding provision 2005, this section shall comply with the added provision.
This section was proposed by China Electrical Equipment Industrial Association.
This part of the jurisdiction of the National Power Tools Standardization Technical Committee (CAS/T C68) and is responsible for interpretation.
This section of Shanghai Electric Tool Research Institute is responsible for drafting.
This part drafter. Liu Jiang, Li Bang Association.
Previous versions of this part of the case instead of the standard release.
--- GB 3883.16-1993.
GB 3883.16-2008/IEC 60745-2-16.2008
Safety of hand-held power tools
Tackers requirements for. a second portion
Range 1
In addition to the following provisions, GB 3883.1 of this chapter apply.
1.1 adds.
This section applies to the general-purpose nailing machine. This does not apply to industrial products nailing machine equipment.
2 Normative references
GB 3883.1 of this chapter apply.
Definition 3
In addition to the following provisions, GB 3883.1 of this chapter apply.
Increased definition.
3.101
Force acting on the engaging member of the internal load, such as a metal pin, nail or staple, driven into the wood so that the engaging member, plastic, fiberboard, or the like
Tools and Materials.
3.102
A trigger, a workpiece contacting and/or other operation of the controller, alone or in some combination or order to run the tool.
3.103
Actuator system according to one or more of the operation of the controller, the controller starts operation of a particular order to run the tool. When the addition of the workpiece
When a specific operation of the controller other than the contacts are released and re-start, the additional actuator is possible.
3.104
An operating system operating more than one controller, the controller starts a specific order to run the tool. Only when all the control operations
When the system is released in the same order and are restarted possible additional actuator.
3.105
An operating system operating more than one controller, the operation of the controller in any order to start the operation of the tool. When any operation
When the controller is released, and for restarting the additional actuator it is possible.
3.106
That allows the following operation system. single actuator sequence, ordered or disordered Actuator operation of two or more independently movable operation system selected
Operation system. Selecting one or more than one actuator is a single sequence or ordered actuator.
3.107
Actuator system according to one or more of the operation of the controller, the controller can operate in either order to start the operation of the tool. Operating System
GB 3883.16-2008/IEC 60745-2-16.2008
Regardless of the original is designed to order, sequence automatically revert to single actuator, actuator orderly, neutral or off.
3.108
Moving the tool assembly to drive the fastener.
3.109
Can alone, or as part of the operation system of the tool motion controller.
3.110
Operation of the controller unit or the components of the fastening material for an actuator on the tool.
4 General requirements
GB 3883.1 of this chapter apply.
General requirements for tests 5
In addition to the following, GB 3883.1 of this chapter apply.
increase.
5.101 not loaded engaging member to be tested on the operation tool, the tool may make to abnormal stresses. To avoid this, mention may be
For an appropriate test fixture or suggested different methods of operation.
6 Void
Category 7
GB 3883.1 of this chapter apply.
8 signs and instructions
In addition to the following, GB 3883.1 of this chapter apply.
8.1 Addition.
--- for the selective reduction tool from the actuator or the actuator. Description operation system which is available any time mark.
8.12.1 increase.
Special tools for nailing machine safety warnings in provisions 8.12.1.101. These warnings term nailing machine according to special tools
Alternatively the designated term, e.g. stapler, nailer like.
Safety manual nailing machine 8.12.1.101
Nailing machine safety warnings.
--- Always believed to contain the engaging member within the tool. Improper handling can cause unexpected nailing machine firing engaging member and causing personal injury.
--- Do not use the tool and align themselves next. Accidental triggering the emission engaging member causing injury.
--- after the tool onto the workpiece firmly the tool operation. If the tool is not in contact with the workpiece engaging member may deviate from a target.
--- When the card engaging member in the tool, unplug. If nailing machine plugged in, upon removal of the jammed fastener, nailing machine
You might accidentally start.
--- the engagement member during the removal of the jammed special care. When trying to release the jammed state, means may be in a compressed state, the engaging member
It may be a strong pop.
Note. do not use the kinetic energy stored in driving engagement member nailing machine according to the warning can be ignored.
--- When the cable fixing operation, that the cable is not energized. Holding the nailing machine only by grasping surfaces insulated. Use only cable
GB 3883.16-2008/IEC 60745-2-16.2008
Installing a dedicated engaging member. Check that the operating member engaging the insulation of the cable is not damaged. Damage to the fastener will cause the cable insulation
Electric shock and fire hazard.
NOTE. This provides a warning to the appropriate cable fixed nailing machine.
--- This nailing machine can not be used to secure the cable. It is not designed for cable installation, it may result in electrical damage the cable insulation and
Strike or fire hazard.
NOTE. This is not suitable for warning provided to the fixed cable nailing machine.
8.12.2 Chou) increase.
101) recommended type and size of the fastener, or the manufacturer's serial number;
102) and tool operations information operation of the controller;
103) How safe operation of the tool, so that the operator or other person who is in the vicinity of the damage to a minimum;
104) The information nailing machine is adapted to hold cables;
105), if applicable, information for fixing the cable engaging member.
9 protection against contact with live parts
GB 3883.1 of this chapter apply.
10 start
GB 3883.1 of this chapter apply.
Power input and current 11
In addition to the following, GB 3883.1 of this chapter apply.
11.1 for the change.
Rated current deviation measured current is within ± 20%, rated input power is available from the rated current is calculated.
For labeled with one or more tools rated voltage range, the lower limit of the test should be carried out in the range, unless the flag or input rating
Ratio corresponding to the average of the voltage range, in which case, tests were performed at the average of the voltage range.
Is checked by the following tests.
In the operation of a rate of once per second or press tool design rate limit, not an operating tool engaging attachments. The measured current value 10s
Valid values.
12 fever
In addition to the following provisions, GB 3883.1 of this chapter apply.
12.2 for the change.
Operating tool is not installed fastener 10 cycles or until the temperature stabilized, taking a prior reached. Each cycle consisted of once per second in operation
Press tool design limits the rate or operating rate 1min, and the power tool off 3min composition. Measuring the temperature rise in the "on" period.
According to the manufacturer's choice, the tool may be operated continuously until thermal stability.
Leakage current 13
GB 3883.1 of this chapter apply.
14 moisture resistance
GB 3883.1 of this chapter apply.
Electrical strength 15
GB 3883.1 of this chapter apply.
GB 3883.16-2008/IEC 60745-2-16.2008
Overload protection circuit 16 and its associated transformer
GB 3883.1 of this chapter apply.
17 Endurance
In addition to the following, GB 3883.1 of this chapter apply.
17.2 for the change.
1.1 times the rated voltage, the tool engagement member not equipped to perform a predetermined operation 10,000 circulation rate of 12.2 and 0.9 fold
Rated voltage then 10,000 actions.
Switch can not be mounted on the tool to turn on and off the tool.
During the test, if desired, such as to allow the brush to the tool replacement by normal use, greasing.
If any part of the tool temperature exceeds the temperature rise determined during the test 12.1, and stop the forced cooling.
During these tests, overload protection devices shall not operate.
It allows the replacement of damaged does not affect the safety of machine parts during the test.
18 abnormal operation
In addition to the following, GB 3883.1 of this chapter apply.
18.12 for the change.
Class Ⅰ Ⅱ tool uses the class structure (see 5.10) and class Ⅱ tool should operate without affecting the protection against electric shock in extreme overload conditions.
It is checked by the following tests were performed on a single prototype.
Like all users without tools easily contact to the fuse, circuit breakers and overload thermal and 18.1 should be predetermined
Short circuit.
It is connected to the sample loop of not less than 12kVA. The tool armature/rotor locked, the solenoid or to the tool design, even
Continued 15min or until the power-tool or open flame appears. If either occurs immediately after the energization is stopped, if the flame appears, with two
Carbon dioxide (CO2) fire extinguisher. In Chapter 13 of the measured leakage current between live parts and accessible parts throughout the trial
After the process and the test should be monitored until the leakage current stabilizes or drops. Leakage current should be less than 2mA.
After the tool is cooled to room temperature, in Chapter 15 of the electric strength test between live parts and accessible parts.
--- If the tool does not run after 15min, the electric strength test applying 1500V.
--- If the tool to run after 15min, the electric strength test applying 2500V.
19 mechanical hazards
In addition to the following, GB 3883.1 of this chapter apply.
19.101 increase.
Tool user should be provided with a trigger operation to trigger the release position (e.g. in the "OFF" position) will not move the tool, and
And one of the following two.
a) having a workpiece contact, and only when the trigger is operated tools are movable contactor, it is possible to operate the tool;
b) designed to. the engagement member away from tool speed in air is not more than 15m/s, the quality is not greater than 0.3g.
Further, without first operating trigger or the workpiece contact, can not be continuously emitted engaging member.
It was observed in every possible position by the use of the tool, and found to test measurements.
19.102 tool should be.
--- meet or manufactured with a single order, the ordered, or selective automatic reset actuator operation system requirements;
--- has workpiece contact is designed to. In addition to the weight distribution of the force, the tool should be 50% by mass of the tool force is applied to the workpiece,
However, the force is not more than 5N, which makes the engagement member is released. Without cable and the engaging member when the quality measurement tool.
GB 3883.16-2008/IEC 60745-2-16.2008
By measuring and testing the test hand, the engaging member is placed on a horizontal plane, the excitation direction of the workpiece contact is vertical.
19.103 pairs of tools require contact with the workpiece when holding the tool trigger from any rest position while lifting it impossible operation.
Inspection by the following test.
A minimum number of tools mounted on the engagement member, and placed in a horizontal plane, a force of 25% by mass of the tool is applied to the top tool. Then move
The point of application, with a 12mm round bar lift tool in the middle of the trigger. Means shall be provided to ensure that during the test tool to the inclined side surface is no greater than 10 °.
During the test tool shall not operate.
25% of the calculated force times the mass of the tool without using the power supply line and the mass of the tool engagement member.
19.104 tool selection is made with the actuator member, it should be shipped in a single sequence or actuator, fully programmable actuator, neutral, or in the selection
The closed block.
Checked by inspection.
19.105 contacts the workpiece should be designed such that if it will result in failure as long as the individual operating tool will trigger operation, the workpiece should be prevented
Premature failure of the tool Contactor normal use.
Failure analysis or by the following test to test.
Workpiece contact operating 50,000 cycles at a maximum stroke. After this treatment, the trigger is pulled in any direction should not only
Make the tool action. During the above process does not require the operation tool, it will not change unless the force acting on the workpiece or travel contactor.
20 Mechanical strength
GB 3883.1 of this chapter apply.
21 structure
In addition to the following, GB 3883.1 of this chapter apply.
21.18.1 change as follows.
There should be a switch or a workpiece in the locking means contacts the "on" position.
Internal wiring 22
GB 3883.1 of this chapter apply.
23 components
GB 3883.1 of this chapter apply.
24 and the external power supply cord coupling
GB 3883.1 of this chapter apply.
The outer lead terminals 25
GB 3883.1 of this chapter apply.
Grounding device 26
GB 3883.1 of this chapter apply.
The coupling member 27 with a screw
GB 3883.1 of this chapter apply.
28 creepage distance and clearance distance through insulation
GB 3883.1 of this chapter apply.
GB 3883.16-2008/IEC 60745-2-16.2008
29 in heat resistance, flame retardancy and resistance to tracking
GB 3883.1 of this chapter apply.
30 rust
GB 3883.1 of this chapter apply.
31 Radiation, toxicity and similar hazards
GB 3883.1 of this chapter apply.
GB 3883.16-2008/IEC 60745-2-16.2008
appendix
GB 3883.1 Appendix apply.
Appendix K
(Normative)
Tool battery and battery box
Unless otherwise provided in this appendix, all the second part of the chapter are applicable.
K. 12.1 change.
Paragraph 2 is changed to the following.
The operation member is not fitted to the tool engagement following operation cycles, whichever is reached first by.
--- 10 cycles, or
--- until the temperature reaches a stable, or
--- Since the tool until fully discharged battery can no longer operate.
Each cycle consists of tool operations to a rate of once per second or press tool design limits the rate of operation of 1min, stop and turn off the power tools
3min composition. Temperature Rise "on" period measurement. According to the manufacturer's choice, the tool may be operated continuously until thermal stability.
Appendix L
(Normative)
Power source coupled to provide non-isolated tool battery and battery box
L. Range 1
Unless otherwise provided in this appendix, all the second part of the chapter are applicable.
L. Heating 12
This chapter is only applicable to tools configured to direct connection to the mains supply or non-isolated power supply.
Tool also charged while performing the intended function, the charger connected to the test, the operation is not attached to the periphery of the engaging member
Period, whichever is reached first by.
--- 10 cycles, or
--- until the temperature reaches a stable, or
--- Since the tool until fully discharged battery can no longer operate.
Allow the tool to charge the battery when not operated, so that the test was repeated.
Each cycle consists of the operation rate of once per second or press tool design limits the rate of operation of 1min, stop and turn off the power tools group 3min
to make. Temperature Rise "on" period measurement. According to the manufacturer's choice, the tool may be operated continuously until thermal stability.
GB 3883.16-2008/IEC 60745-2-16.2008
references
GB 3883.1 references apply.
GB 3883.16-2008/IEC 60745-2-16.2008
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 3883.16-2008_English be delivered?Answer: Upon your order, we will start to translate GB 3883.16-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 3883.16-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 3883.16-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 3883.16-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 3883.16-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|