GB 32275-2015: Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 32275-2015English239 Add to Cart 3 days [Need to translate] Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry Valid GB 32275-2015

PDF similar to GB 32275-2015


Standard similar to GB 32275-2015

GB 17440   GB 17440   GB/T 17919   GB 32276   

Basic data

Standard ID GB 32275-2015 (GB32275-2015)
Description (Translated English) Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry
Sector / Industry National Standard
Classification of Chinese Standard C67
Classification of International Standard 13.230
Word Count Estimation 11,168
Date of Issue 2015-12-10
Date of Implementation 2017-01-01
Quoted Standard GB 12476.1; GB 12476.2; GB 15577; GB/T 15604; GB 50058; GB 50565
Regulation (derived from) National Standard Announcement 2015 No.38
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the types of safety devices for fire-proof and explosion-proof piping in the textile industry, the use of ports, selection principles, installation and maintenance. This standard is applicable to the design, installation, use and maintenance of safety devices for fire-proof and explosion-proof pipes in the textile industry.

GB 32275-2015: Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry ICS 13.230 C67 National Standards of People's Republic of China Textile industry pipeline fire and explosion safety devices specifications Published 2015-12-10 2017-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative References 1 Terms and definitions 1 3 General provisions 2 4 5 type fire and explosion safety device conduit 2 6 range 3 7 3 selection principles The sensor circuit 3 and 8 9 explosion suppression transmitter 3 10 automatic sprinkler 3 11 Installation 4 12 use and maintenance 4

Foreword

In addition to all the technical criteria present in Chapter 1, Chapter 2, and Chapter 3 7.2,7.3,9.3 mandatory content. This standard was drafted in accordance with rules GB/T 1.1-2009 given. This standard was proposed by the State Administration of Production Safety Supervision and Management. This standard by the National Safe Production Standardization Technical Committee (SAC/TC288). This standard was drafted. Wuhan Textile University, Wuhan Steel Group Environmental Safety Institute, Jiangsu Buffett filter Co., Hai Yi Jin Air Equipment Co., Ltd. The main drafters. Shi Jianzhong, Xu Guoping, Wangxiu Qing, Wang Aimin, Li Yu, Cai Sheng, Ding Jingzhi, Wang Zhenggang, Chen Jun, Wu Xiaoyu, There Bang music. Textile industry pipeline fire and explosion safety devices specifications

1 Scope

This standard specifies the type of textile fire and explosion safety device conduit, range, selection principle, installation and maintenance. This standard applies to the textile industry pipeline fire and explosion safety device design, installation, use and maintenance.

2 Normative references

The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document. GB 12476.1 combustible dust electrical equipment - Part 1. General requirements (IEC 61241-0.2004, MOD) GB 12476.2 combustible dust electrical equipment Part 2. Selection and installation (IEC 61241-14.2004, IDT) GB 15577 Dust explosion safety regulations GB/T 15604 dust explosion term GB 50058 explosive atmospheres design specifications of electrical installations GB 50565 Textile fire protection engineering design

3 Terms and Definitions

GB/T 15604 and as defined in the following terms and definitions apply to this document. 3.1 Dust explosion hazard dustexplosionhazardousarea The presence of combustible dust, combustion gases and place ignition sources. [GB/T 15604-2008, definitions 3.13] 3.2 Textile Industry textileindustry Natural or natural fibers, synthetic polymer compound as raw material, chemical and physical methods to obtain fibers, and these Fiber production of various products of the industrial chain. Including. textiles, textile and garment industry, chemical fiber manufacturing, chemical fiber raw materials manufacturing industry. 3.3 Pipeline fire and explosion safety devices pipelinesafetyapparatusoffiredampersandexplosionprotection Installed in the ventilation and dust removal, in the pneumatic conveying conduit, means for preventing explosion or explosion, fire spread. 3.4 Valve arrester firearrestingvalve When an explosion or fire, safety devices to prevent the passage of flame. 3.5 Photosensor opticalelectronicsensor Explosion for sensing a signal emitted when the flame of fire, and passes the information to other detection means. Including infrared, purple rumor Sensors and the like. 3.6 Pressure wave sensor pressuresensor For sensing the pressure and shock wave impulse signal when the explosion occurred, and passes information to other detection means. 3.7 Chemical isolation chemicalisolation When an explosion or fire, explosion suppression agent is released by an explosion or fire zone isolation areas and other areas, to prevent explosion or fire diffusion. 3.8 Mechanical isolation mechanicalisolation When a fire or explosion, through the valve explosion or fire areas and other regions zonal isolation, prevent the spread of fire or explosion. 3.9 Explosion suppression transmitter explosionsuppressor When an explosion or fire, explosion suppression agent transmitting means. 3.10 Automatic sprinkler automaticsprinkler When a fire or explosion, with automatic sprinkler nozzle.

4 General Provisions

4.1 pipeline fire and explosion safety device used in the textile industry, ventilation and dust removal dust explosion hazardous areas of zones 20, 21, pneumatic conveying And other pipeline. 4.2 Role pipeline fire and explosion safety devices are. a) preventing flame spread of fire through the conduit when the dust explosion hazard cause dust explosion; b) When a region of explosion, through the isolation, and other measures to prevent flame spread and prevent multiple explosions; c) prevent the spread of fire in different regions, in place of GB 50565 damper function. Type 5 pipeline fire and explosion safety devices This standard including but not listed in Table 1 several types of safety devices. Table pipeline type fire and explosion safety device 1 Type constitute Remarks Mechanical isolation valve A valve body, valve plate, sensors, power (standby power Pool), the control system Comprising a collapsible valve, gate valve, the valve arrester. sensor Pressure wave sensor comprises a photosensor Chemical isolation valve A transmitter, a sensor, a power supply (battery backup), control Braking system Wave sensor comprises a pressure sensor, a photosensor Sensor Extinguishing fire detection system Automatic sprinkler, sensors, power source (battery backup), Control System Sensor including ultraviolet, infrared and other photoelectric sensor

6 range

Following locations pipe should be installed fire and explosion safety devices. a) into the dust chamber, the duct; b) through the pipeline different dust explosion hazardous areas; c) carding plant pneumatic conveyor; d) through the dust pipe different fire district in dust explosion hazardous areas.

7 selection principles

7.1 into and out of the pipe should dust chamber isolation valve with mechanical or chemical isolation valve. The maximum side length of pipe or equivalent diameter not Should be greater than 300mm mechanical isolation valve, valve blocking time should be less than 80ms; equivalent pipe length or a maximum diameter of edge 300mm should be used to isolate chemical safety valve. Dust explosion hazard across different regions within the duct should be 7.2 textile industrial plants mechanical isolation valve or extinguish fire detection system. 7.3 textile industry pneumatic conveying system piping extinguish fire detection system should be adopted.

8 and the sensor circuit

8.1 sensing control response time should be less than 20ms. 8.2 pipeline fire and explosion safety sensor means may employ a pressure wave sensor, an ultraviolet sensor, an infrared sensor 3 in any kinds of sensors One; triple sensor may also be employed, when the two sensors generating a response, the security device is activated. 8.3 mating electrical circuits and products should meet GB 12476.1 and GB 12476.2 requirements. 8.4 using electric brake safety device should have a backup power supply when the external power supply failure also the brake. 8.5 sensors should fire alarm system, security control interlock system; a plurality of sensors may control a safety device.

9 explosion suppression transmitter

9.1 explosion suppression. Specification. a) Spray lag time. less than 20ms; b) Fogging time. 3m2 area of less than 150ms; c) duration of the available matte. greater than 500ms; d) spray rate. more than 80%. 9.2 explosion suppression transmitter different capacities should be selected according to the pipe diameter. 9.3 explosion suppression transmitter should be at 45 ° angle bracket mounted on the pipe, and the best results explosion suppression agent is sprayed into the flame. 10 automatic sprinkler 10.1 sprinkler technical parameters. a) Spray lag time. less than 20ms; b) Fogging time. 3m2 area of less than 150ms. 10.2 extinguish fire detection system should be wet sprinkler. The fire protection sprinkler system is a wet direct therewith nearest Connection. 10.3 The installation location may drop below freezing ambient temperatures, sprinkler use an electric heating mode to prevent freezing of water or showerhead freeze. 10.4 sprinkler should be installed on a horizontal pipe, downstream of the sensor should be installed, the pipe should be installed in the top head. 11 Installation 11.1 should be carefully checked before installation models, specifications meet the design requirements, factory inspection certificate, certificate, manual, and in strict accordance with established Preparation of installation instructions. 11.2 mechanical isolation valve should be installed on a horizontal pipe, the mechanical braking device to be checked is normal prior to installation. 11.3 directional safety device, and the flow conduit should be noted that the arrows in the air flow in the same direction when installed. 11.4 security device with a sensor which sensor should be installed near high dust explosion risk areas, safety devices and sensors should be maintained More than 5m from the hold. 11.5 safety device should be mounted on the pipe to facilitate checking operation, and should separate stand alone. 11.6 the connection cable between the devices should meet GB 12476.1, GB 12476.2 and GB 50058 is required. 11.7 If the ambient temperature is too high, exceeding the allowable temperature and electrical cables shall take the necessary protective measures. 11.8 mechanical isolation valve flange connection should, at a pad connection should not use animal or plant fibers, and applying jumper wires, electrically Resistance is not greater than 0.03Ω. Sprinkler fire detection and extinguishing transmitter system 11.9 chemical isolation valve may be directly mounted on the pipe, the insertion port should be soldered and the solder It should be finished sealing test. 11.10 installation design documents should be prescribed for debugging, each security device debugging of not less than three times, and make debug logging. 12 use and maintenance 12.1 enterprises should arrange for someone to manage and maintain safety equipment, management personnel should be subject to pre-job safety training and obtain professional certification. 12.2 should regularly check whether the failure of a safety device, such as the failure of timely maintenance, and make a record. Maintenance 12.3 proof safety device should be used tool, each metal member not hitting the safety device. 12.4 GB hot work should be related to implementation of the provisions in 15577.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 32275-2015_English be delivered?

Answer: Upon your order, we will start to translate GB 32275-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 32275-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB 32275-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.