US$139.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 31656.6-2021: National food safety standard - Determination of eugenol residues in aquatic products by gas chromatography mass spectrometry method Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 31656.6-2021 | English | 139 |
Add to Cart
|
3 days [Need to translate]
|
National food safety standard - Determination of eugenol residues in aquatic products by gas chromatography mass spectrometry method
| Valid |
GB 31656.6-2021
|
PDF similar to GB 31656.6-2021
Basic data | Standard ID | GB 31656.6-2021 (GB31656.6-2021) | | Description (Translated English) | National food safety standard - Determination of eugenol residues in aquatic products by gas chromatography mass spectrometry method | | Sector / Industry | National Standard | | Classification of Chinese Standard | X20 | | Word Count Estimation | 7,786 | | Issuing agency(ies) | National Health Commission of the People's Republic of China, State Administration for Market Regulation |
GB 31656.6-2021: National food safety standard - Determination of eugenol residues in aquatic products by gas chromatography mass spectrometry method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National food safety standards
Determination of eugenol residues in aquatic products
Gas Chromatography-Mass Spectrometry
National Standards of People's Republic of China
Released by the National Health Commission of the People's Republic of China
State Administration for Market Regulation
Ministry of Agriculture and Rural Affairs of the People's Republic of China
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
This document is published for the first time:
National food safety standards
Determination of eugenol residues in aquatic products by gas chromatography-mass spectrometry
1 Scope
This document specifies the sample preparation and gas chromatography mass spectrometry methods for detecting eugenol residues in aquatic products:
This document is suitable for the detection of eugenol residues in edible tissues of fish and shrimp:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative citations in the text: Among them, the cited documents with dates are:
Only the version corresponding to the date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document:
document:
GB/T 6682 Specifications and test methods for water used in analytical laboratories
GB/T 30891-2014 Sampling specifications for aquatic products
3 Terms and definitions
There are no terms or definitions that need to be defined in this document:
4 Principles
The residual eugenol in the sample was extracted with acetonitrile, purified with a solid phase extraction column, degreased with n-hexane, measured by gas chromatography mass spectrometry, and quantified by the internal standard method:
55:1 Reagents
5:1:1 Acetonitrile (CH₃CN): chromatographically pure:
5:1:2 n-hexane (C₅H): chromatographically pure:
5:1:3 Ethyl acetate (CH₃COOCH₂CH₃): chromatographically pure:
5:1:4 Methanol (CH₃OH): chromatographically pure:
5:2 Solution preparation
5:2:1 Methanol solution: Take 10mL of methanol and add water to 100mL:
5:2:2 Acetonitrile-saturated n-hexane: Put:200 mL of n-hexane into a 250 mL separatory funnel, add an appropriate amount of acetonitrile, shake vigorously, and after the distribution is balanced, discard the lower acetonitrile layer to obtain:
5:3 Standard products
5:3:1 Eugenol (Eugenol, C10H12O2, CAS number: 97-53-0), content ≥ 99%:
5:3:2 Deuterated eugenol (Eugenol-d3, C10H9D3O2, CAS number: 1335401-17-6), content ≥ 99%:
5:4 Preparation of standard solution
5:4:1 Eugenol standard stock solution: Take 10 mg of eugenol standard, weigh it accurately, dissolve it in ethyl acetate and dilute it to 100 mL brown volume:
Use a measuring flask to prepare a standard stock solution with a concentration of 100 μg/mL: Store in a dark place below -18°C and has a validity period of 2 months:
5:4:2 Internal standard stock solution: Take 10 mg of deuterated eugenol standard, weigh it accurately, dissolve it in ethyl acetate and set it to a 100 mL brown volumetric flask to prepare an internal standard stock solution with a concentration of 100 μg/mL: Store away from light below -18℃, valid for 2 months:
5:4:3 Eugenol standard working solution: Accurately pipet an appropriate amount of eugenol standard stock solution and dilute it with ethyl acetate to a standard working solution with a concentration of 1 μg/mL:
For liquid use, store at 4°C away from light, valid for 1 month:
5:4:4 Internal standard working solution: Take an appropriate amount of the internal standard stock solution and dilute the standard working solution with a concentration of approximately 1 μg/mL with ethyl acetate: Keep away from light at 4°C:
Save, valid for 1 month:
5:5 Materials
5:5:1 Solid phase extraction column (C18): 300mg/3mL, or equivalent:
5:5:2 Stoppered plastic centrifuge tube: 50mL:
5:5:3 Nylon microporous filter membrane: 0:22μm:
6 Instruments and equipment
6:1 Gas chromatograph-tandem mass spectrometer: equipped with electron bombardment ionization ion source:
6:2 Analytical balance: sensitivity 0:01g and sensitivity 0:00001g:
6:3 Nitrogen blowing instrument:
6:4 Vortex mixer:
6:5 Centrifuge: 4000r/min:
6:6 Ultrasonic oscillator:
6:7 Homogenizer:
7: Preparation and preservation of samples
7:1 Preparation of samples
Prepare samples according to the requirements of Appendix B in GB/T 30891-2014:
a) Take a homogeneous test sample as a test material;
b) Take a homogeneous blank sample as a blank sample;
c) Take a homogeneous blank sample, add standard working solution of appropriate concentration, and add the sample as a blank:
7:2 Storage of samples
Store below -18℃:
8 Measurement steps
8:1 Extraction
Take about 2g of the sample (accurate to ±0:02g), put it into a 50mL plastic centrifuge tube with a stopper, add 0:1mL of internal standard working solution and 10mL of acetonitrile, and vortex
Spin for 1 minute, sonicate for 10 minutes, and centrifuge at 4000 r/min for 5 minutes: Put the supernatant into another 50 mL plastic centrifuge tube with a stopper: Repeat the extraction of the residue once with 10 mL of acetonitrile, and combine the supernatants: Add 10 mL of acetonitrile-saturated n-hexane, skim, and vortex: ,1min, centrifuge at 4000r/min
After 5 minutes, take the acetonitrile layer and repeat degreasing once as described above: Blow nitrogen in a 45°C water bath until it is almost dry, add 10 mL of methanol aqueous solution to dissolve:
spare:
8:2 Purification
The solid-phase extraction column was activated with 3 mL of methanol and 3 mL of water each in sequence: Pass the backup solution through the column, add 3 mL of water to rinse, drain for 5 min, and add 3 mL of methanol:
Elute, take the eluate, blow dry with nitrogen, add 1:0 mL of ethyl acetate to dissolve, filter with a 0:22 μm filter, and measure by gas chromatography and mass spectrometry:
8:3 Preparation of standard curve
Precisely measure an appropriate amount of eugenol standard working solution and internal standard working solution, and dilute it with ethyl acetate into a series of standard working solutions with concentrations of 4 μg/L, 10 μg/L, 40 μg/L, 100 μg/L, 400 μg/L, and 800 μg/L: :The content of deuterated eugenol in the standard working solution is 100 μg/L: It is ready for use: Inject a series of standard working solutions, take the peak area ratio of eugenol and deuterated eugenol as the ordinate, and the corresponding eugenol concentration is On the abscissa, draw the standard working curve: Find the regression equation and correlation coefficient:
8:4 Determination
8:4:1 Gas chromatography reference conditions
GB 31656:6-2021
a) Syringe: 10:0μL, or equivalent;
b) Chromatographic column: capillary column (packing material: 5% G-phenylmethylpolysiloxane, such as HP-5, specification: 30m×250μm×0:25μm), or equivalent;
c) Injection method: splitless injection;
d) Carrier gas: helium, purity 99:999%, flow rate 1:0mL/min;
e) Injection volume: 2:0μL;
f) Inlet temperature: 280℃;
g) Column temperature: starting temperature is 70°C, hold for 1 minute; increase temperature to 120°C at 40°C/min, increase temperature to 170°C at 10°C/min, keep
Hold for 3 minutes:
8:4:2 Mass spectrometry reference conditions
a) Ion source: EI source;
b) Electron energy: 70eV;
c) Ion source temperature: 280℃;
d) Quadrupole temperature: 150℃;
e) Interface temperature: 280℃;
f) Rear operating temperature: 280℃, 3min;
g) Solvent delay: 4:0min;
h) Determination method: multiple reaction (MRM) monitoring mode, the reference values of qualitative ion transition, quantitative ion transition and retention time are detailed in Table 1:
8:4:3 Determination method
Take the sample solution and standard solution, conduct single-point or multi-point calibration, quantify by chromatographic peak area, and calculate by internal standard method: Standard solution and sample solution
The characteristic ion mass chromatographic peak area of the target compound should be within the linear range of instrument detection: The characteristic ion mass chromatographic peak area of eugenol in the sample solution
The peak areas of sub-mass chromatograms should be within the linear range of instrument detection: The relative ion abundance in the sample solution is the same as the relative ion abundance in the standard solution:
Compared with the abundance, it meets the requirements of Table 2: The characteristic ion mass chromatogram of the standard solution is shown in Appendix A:
8:5 Blank test
Take a blank sample and perform parallel operations using the same measurement steps except that no standard solution is added:
9 Calculation and presentation of results
The residual amount of the drug to be tested in the sample is calculated according to the standard curve or formula (1):
10 Sensitivity, accuracy and precision of detection methods
10:1 Sensitivity
The detection limit of this method is 2:5 μg/kg, and the quantification limit is 10 μg/kg:
10:2 Accuracy
The recovery rate of this method is 70% to 120% at the added concentration level of 10μg/kg~200μg/kg:
10:3 Precision
The intra-batch relative standard deviation of this method is ≤20%, and the inter-batch relative standard deviation is ≤20%:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 31656.6-2021_English be delivered?Answer: Upon your order, we will start to translate GB 31656.6-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 31656.6-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB 31656.6-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|