|
US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 2797-2008: [GB/T 2797-2008] Technical specification for lamp caps Status: Valid GB 2797: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 2797-2008 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
[GB/T 2797-2008] Technical specification for lamp caps
| Valid |
GB 2797-2008
|
| GB 2797-1994 | English | 70 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
General specifications for lamp caps
| Obsolete |
GB 2797-1994
|
| GB 2797-1981 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
General specifications for lamp caps
| Obsolete |
GB 2797-1981
|
PDF similar to GB 2797-2008
Basic data | Standard ID | GB 2797-2008 (GB2797-2008) | | Description (Translated English) | [GB/T 2797-2008] Technical specification for lamp caps | | Sector / Industry | National Standard | | Classification of Chinese Standard | K74 | | Classification of International Standard | 29.140.10 | | Word Count Estimation | 12,129 | | Date of Issue | 2008-12-15 | | Date of Implementation | 2010-01-01 | | Older Standard (superseded by this standard) | GB 2797-1994 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 21 of 2008 (No. 134 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies the various metal lamp, ceramic lamp holder and plastic cap safety requirements, test methods, inspection rules, marking, packaging, transportation and storage. This standard applies to the finished screw on the lamp type, pin type, pre-focus type, miscellaneous and bayonet cap. |
GB 2797-2008: [GB/T 2797-2008] Technical specification for lamp caps---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification for lamp caps
ICS 29.140.10
K74
National Standards of People's Republic of China
Replacing GB 2797-1994
General technical conditions of the cap
Posted 2008-12-15
2010-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
All the technical contents of this standard is mandatory.
This standard shall be used together with the relevant product standard lamp, if any difference to the standard lamp shall prevail.
This standard replaces GB 2797-1994 "General technical conditions of the cap."
The main differences between this standard and GB 2797-1994 are as follows.
--- Increasing the definition of a chapter, an increase in Appendix A;
--- References to chapters, mechanical strength, test methods, inspection rules were modified.
Appendix A of this standard is an informative annex.
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized.
This standard drafting unit. Beijing Lighting Research Institute, Deqing new Minghui Light Sources Ltd..
The main drafters of this standard. Qusu Hui, Yang Xiaoping, Zhao Xiurong, Jiang Shan, Qian Fang, Li Xiaoqing, Duan Yan Fang.
This standard replaces the standards previously issued as follows.
--- GB 2797-1981, GB 2797-1994.
General technical conditions of the cap
1 Scope
This standard specifies the various metal lamp, ceramic lamp holder - Safety requirements and plastic cap, test methods, inspection rules, marking, packaging, transportation
Transport and storage.
This standard applies to screw-on finished lamp on the pin type, pre-focus type, and miscellaneous bayonet cap.
Note 1. The standard eligibility conditions involve only safety indicators lamp, the lamp does not consider the specific type and size requirements. Use of this standard should reference
GB/T 1406 series of standards.
Note 2. In addition to the screw type, pin type, pre-focus type and bayonet cap, are classified as miscellaneous cap.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 191 packaging and marking transport and storage (GB/T 191-2008, ISO 780.1997, MOD)
safety-Part 3. gaugesMOD)
GB/T 1483.3 Lamp caps Gauges - Part 3. pre-focus lamp holder, lamp holder gauge (GB/T 1483.3-2008,
IEC 60061-3.2007, Lampcapsandholderstogetherwithgaugesforthecontrolofinterchangeability
andsafety-Part 3. gaugesMOD)
GB/T 1483.5 Lamp caps Gauges - Part 5. bayonet lamp holder gauge (GB/T 1483.5-2008,
IEC 60061-3.2007, Lampcapsandholderstogetherwithgaugesforthecontrolofinterchangeability
andsafety-Part 3. gaugesMOD)
GB/T 2900.65 Electrotechnical terminology Lighting ((GB/T 2900.65-2004, IEC 60050 (845). 1987, MOD)
GB/T 5169.10 Fire hazard testing for electric and electronic products - Part 10. Glowing/hot wire based test methods - Glow wire mounted
Set Common test methods (GB/T 5169.10-2006, IEC 60695-2-10.2000, IDT)
GB/T 21098-2007 Lamp caps and test its safety and interchangeability gauge Part 4. Guidelines and general information
(IEC 60061-4.2004, IDT)
IEC 60061-2 Lamp caps and holders of interchangeability and safety gauges - Part 2. Lampholders
IEC 60061-3 Lamp caps and holders of interchangeability and safety gauges - Part 3. Gauges
3 Terms and Definitions
GB/T 2900.65 determined and the following terms and definitions apply to this standard.
3.1
To use sockets or light fittings lamp components and power connections, and in most cases for fixing the lamp holder. [845
08-15]
3.2
Lamp housing can be screwed into the holder with the threaded cap (international name E-type). [845-08-16]
3.3
Cap lamp housing can be snapped to the socket with groove pins (International Nomenclature B type). [845-08-17]
3.4
Lamp into a smooth cylindrical cap (international name S type). [845-08-18]
3.5
On the base with one or more pins of the cap (international name. For a single pin for the F-type; for two or more pins for the G-type).
[845-08-19]
3.6
Light bulb in the manufacturing process in the light emitter mounted on the cap with respect to a particular position of the cap, it will give the bulb inside the lamp holder supporting load
When precise positioning repeatability (International Nomenclature P-type). [845-08-20]
3.7
From the lamp (especially bayonet cap) protruding metal parts on the housing it with the notches on the card fit the lamp cap lamp holder is fixed. [845-08-21]
3.8
On the base (insulated from the housing) is connected to a guide wire, sheet metal lamp for the power supply connected. [845-08-22]
3.9
Fixed end cap is generally cylindrical metal member, to the corresponding jack to connect the lamp socket, or the lamp cap and lamp holder fixed electrical ground
touch. [845-08-23]
3.10
The lamp fixed position, usually inserted therein lamp and lamp power supply and connecting devices. [845-08-24]
3.11
Device consists of an insulator and corresponding elastic connecting components of the connector and the power supply is connected to the lamp, but can not afford to support the lamp effect.
[845-08-25]
3.12
Electrical contact with the lamp holder directly through the end surface of the lamp leads to complete, the glass member (or other insulating material part) of the lamp
End of the match in the socket mounting is essential. Such models are also suitable as a substitute for a whole type lamp end, and in accordance with the same
Independent insulation cap interchangeability requirements.
4 Products
According to the structure characteristics can be divided into.
a) screw-on cap (E);
b) Pin lamp holder (G.F);
c) pre-focus lamp holder (P);
d) recessed lamp (R);
e) cylindrical cap (S);
f) bayonet cap (B);
g) The lamp ends (W).
By Housing Material characteristics can be divided into.
a) a metal cap;
b) ceramic lamp;
c) plastic cap.
5 Technical requirements
5.1 Model and main dimensions
5.1.1 Base Type naming should be consistent with the provisions of GB/T 21098-2007 of.
5.1.2 The main dimensions of the cap should be consistent with GB/T 1406.1, GB/T 1406.2, GB/T 1406.3, GB/T 1406.4 and
GB/T 1406.5 regulations, provisions of this standard Write lamp shall comply with IEC standards.
5.2 material and appearance quality
5.2.1 bayonet cap pins shall be of steel or brass, brass pins and electrical contact pads or the same as the performance of the material should be used
manufacture.
Metal cap insulator glass, ceramics, high temperature resistant bakelite or plastic and other materials should be used.
Plastic cap should be temperature, flame retardant materials to meet the requirements of 5.5 and 5.6.
5.2.2 metal lamp housing surface should be treated against corrosion.
5.2.3 lamp appearance should be smooth, no defects, no wrinkles, no cracks, no scratches pin, the outer surface of the coating should have bubbled serious passivation solution
Marks and partial uncoated defects.
5.2.4 coating the inner surface of the cap should not be exposed at the end and there is corrosion phenomenon.
5.2.5 cap coating should have sufficient bonding strength, the test should not have come off and peeling.
5.3 Mechanical strength
5.3.1 cap insulator and the metal housing should be firmly connected lamp should be able to withstand the relevant product standard mechanical strength requirements not specified
Deformation or damage should affect the normal use.
5.3.2 cap insulator and housing, electrical contact pads and pin connections should not be loose phenomenon.
5.3.3 Such lamp with positioning key, be sure a similar type lamps are not interchangeable. The lamp shall comply with the relevant provisions of the standard lamp lights
Head/targeting key requirements.
5.4 insulation resistance and dielectric strength
Insulation resistance 5.4.1 lamp housing and electrical contacts (pins) between, under normal atmospheric conditions should be not less than 50MΩ, in humid atmospheric conditions
Lower parts should not be less than 2MΩ.
5.4.2 between the housing and each one electrical contact (pin) dielectric strength and contacts (pins) and contacts (pins) between the light should be able to withstand the relevant
Product standard requirements without the occurrence of a breakdown or arcing phenomena.
5.5 heat resistance
Cap insulating material should have sufficient heat resistance.
5.6 Ignitibility
Cap insulating material should have high temperature resistant and anti-abnormal combustion performance.
5.7 may unexpectedly live parts
5.7.1 live parts and insulated metal parts may not or should not be charged.
5.7.2 In addition to the cap pins (contacts), the live parts should not highlight any part of the cap.
5.8 creepage distances and clearances
Lamp pins or contact between the cap and the metal housing of the minimum creepage distances and clearances shall comply with GB/T 21098-2007, each
Standard lamp, lamp type size requirements in the standard.
6 Test methods
6.1 General test conditions. temperature of 15 ℃ ~ 35 ℃, relative humidity of 45% to 75%.
6.2 The main dimensions of the lamp (5.1) in line with GB/T 1483.1, GB/T 1483.2, GB/T 1483.3, GB/T 1483.5,
IEC 60061-3 amount of regulatory inspection, lamp standards and criteria specified in the Write Write a predetermined gauge lamp test available
IEC 60061-3 predetermined gauge inspection.
6.3 material and appearance quality (5.2.1,5.2.3,5.2.4) test method with the appearance.
6.4 coating bond strength (5.2.5) test by heating test. 5min specimen was hold at a temperature of 300 0-5 ℃, and then the coating was observed to be
No loss, peeling and blistering.
6.5 moisture resistant (5.2.2) in a humid chamber carried out before the sample is placed in the chamber, the cap should be to de-grease process and
When stored at 45 ℃ 2h, the temperature was stabilized sample at a temperature of 40 ℃ ± 2 ℃, relative humidity of 91% to 95% under the condition of holding
48h, the outer surface should not have rust phenomenon.
6.6 insulator connected with the housing, electrical contact pads and pins (5.3.2) with the appearance of the test method.
Connection firmness (5.3.1) and the strength of the connection pin bayonet cap of the housing (5.3.2) 6.7 insulator between the metal housing and should
Separately on a dedicated test device. After the test, the cap should not be damaged in any way affect safety occur.
6.8 targeting key using the appropriate measuring system and/or visual inspection method (5.3.3) eligibility.
6.9 Insulation resistance test (5.4.1) under normal test conditions, the specimen should be stored after 2h measured under these conditions. Under wet conditions,
1h can be stored in humid conditions prescribed under 6.5, measured within 5min after removing from the chamber.
Application of soft paper before measuring the surface of the lamp drops siphoning off applying 500V DC voltage 1min measurement. With the appropriate test equipment
Eligibility.
In the case of the lamp housing is completely made of an insulating material, in accordance with the requirements of IEC 60061-2, the lamp and lamp holder with minimum inclusion size
When connected, the entire test shall be connected together and wrap pins accessible place between the surface of the metal foil.
6.10 cap dielectric strength test (5.4.2), the test should be carried out immediately after the completion of the insulation resistance test 6.9. Using a frequency
2U ± 1000V 50Hz or 60Hz sinusoidal AC voltage, which lasted 1min. U is the rated voltage of the lamp.
Applying a first predetermined voltage value 1/2 at the beginning of the test, then rapidly increased to a predetermined value.
It does not produce significant voltage drop glow discharge is negligible.
6.11 heat resistance test (5.5.1), Test A. the plastic cap placed in a heating oven heated to 130 ℃ ± 2 ℃ holding 48h before use
6.2 The method specified test its main dimensions. After the test, the specimen shall show any weakening of its security changes, especially not
Appear the following conditions.
Performance requirements for protection against electric shock --- 5.4 lowered;
--- Cap pin loose, cracking, bulging and shrinkage, by visual inspection method.
After the test, the dimensions shall comply with the requirements of 5.1.
Test B. The surface of the sample placed horizontally, with a diameter of 5mm steel ball to the surface of 20N beat. If the surface of the test
Now bend the part to prop up the ball pressure.
The test shall be carried out at a temperature of 125 ℃ ± 5 ℃ heating cabinet.
After 1h the ball away, the indentation measured diameter, which should not exceed 2mm.
This test is not made on parts of ceramic.
6.12 Anti-combustibility test (5.6), heated to 650 ℃ with a nickel-chromium glow-wire tests on the specimen. The test apparatus GB/T 5169.10
In a note.
The test sample should be mounted vertically on the stand close to the glow-wire ends, and 1N force is applied. Best part of it is from the upper portion of the test sample
15mm or more than 15mm of the edge positions. The glow-wire into the specimen is mechanically limited to a depth of 7mm. After the 30s, the sample
With glow-wire tip disengagement.
After the sample is removed from the glow wire, any flame on the specimen shall be extinguished in the 30s, and any burning or molten
The whereabouts of the substance should not be ignited horizontally below the specimen at a distance of 200mm ± 5mm of five tissue.
The glow-wire temperature and heating current before the start of the test should be constant 1min. But in the meantime to ensure that heat radiation should not affect the sample.
Sheathed thermocouple wire using highly sensitive measuring glow wire temperature of the top, thermocouple configuration and calibration should be consistent with GB/T 5169.10 requirements.
Note. For personal safety, in the glow-wire test to take measures to prevent the risk of the following occur.
--- Explosion or fire;
--- Inhale smoke and/or toxic substances;
--- Toxic waste.
6.13 may accidentally live parts (5.7), for all product testing requirements for accidentally live parts, the manufacturer shall demonstrate continuous 100%
test. Compliance is checked by appropriate detection system testing, including appropriate use of the visual inspection method. In addition, there should be regular daily equipment
Inspection, acceptance inspection or effectiveness.
6.14 creepage distances and clearances (5.8), in the most unfavorable position of its measurements to verify their eligibility.
7 Inspection rules
Inspection rules using quality assessment rules, including two types of test. Type test and quality conformance inspection. Lamp quality and consistency test
Type test sampling plan eligibility requirements determined in accordance with the implementation of the relevant lamp standards.
7.1 Inspection classification
7.1.1 Type test is the same number of models to test all the items to determine whether the manufacturer has the ability to produce conforming to this standard
Requirements.
7.1.2 Quality test batch consistency test is based on samples taken periodically from the product inspection to determine the production
Whether the process can guarantee the quality remained stable.
7.2 Type tests
7.2.1 type test, carried out in the following cases the look.
a) The new product type;
b) old products to the plant;
c) the main products in the design, technology, materials and spare parts after the change;
Resume production after d) discontinued three months.
7.2.2 Type test items listed in Table 1 and in order.
Table 1
No. Test Item Test Method Terms and Conditions
Main dimensions 5.1.2
5.2.5 Materials and Appearances
Moisture resistance 5.2.2
Coating bond strength 5.2.5
The insulator and the metal shell firmly 5.3.1
The insulator and the metal shell and the pins are not loose 5.3.2
Pin and the metal shell firmness 5.3.2
Targeting key 5.3.3
Insulation resistance (normal) 5.4.1
6.2
6.3
6.5
6.4
6.7
6.6
6.7
6.8
6.9
Insulation resistance (wet) 5.4.1
Dielectric strength 5.4.2
5.5 heat resistance
6.9
6.10
6.11
Anti-flammable 5.6
You may accidentally live parts 5.7
Creepage distance and electrical gap 5.8
6.12
6.13
6.14
8 signs, packaging, transportation and storage
8.1 lamp should be assembled on a solid box. The box should be covered with a vapor barrier, together with a certificate issued by the inspection department.
8.2 on the box should be marked.
a) manufacturer's name and trademarks;
b) the name and model of the cap;
c) number;
d) product standards;
e) the symbol GB/T 191 prescribed;
f) packaging date.
8.3 on each certificate shall specify.
a) Check the date;
b) signature and inspection department inspectors.
8.4 transport process should prevent extrusion, pouring rain and snow attack, the handling process should not be violent collision.
8.5 lamp should be stored in dry, ventilated and non-corrosive gases and substances present, lamp shelf life greater than one year should be re-tested.
Appendix A
(Informative)
Base Type
Screw cap
E5
E10
EP10
EY10
EZ10
E11
E12
E14
E17
E26
E26d
E26/50x39 & E26/51x39
E27
E27/51x39
E39
E40
Bayonet cap
BA7
B8.4d & BX8.4d
BA9
BAX9s
BAY9s
BAW9s
BAZ9s
B15d
BA15
BAU15
BAW15
BAX15d
BAY15d
BAZ15
BA15s-3 (100 °/130 °)
BA20
BA21-3 (120 °)
B22d
Pin lamp
Fc2
Fa4
Fa6
Fa8
G1.27 & GX1.27
G2.54 & GX2.54
GUX2.5d, GUY2.5d & GUZ2.5d
G3.17
G4
GU4
GY4
GZ4
G5
G5.3
G5.3-4.8
GU5.3
GX5.3
GY5.3
G6.35, GX6.35 & GY6.35
GZ6.35
GU6.5
2G7
GU7
2GX7
GZX7d, GZY7d & GZZ7d
G7.9 & GX7.9
2G8
GR8
G8.5
GX8.5
G9
G9.5
GX9.5
GY9.5, GZ9.5, GZX9.5, GZY9.5 & GZZ9.5
G10q
GR10q
GRX10q
B22d-3 (90 °/135 °)/25x26
BY22d
GU10
GU10q
GX10
GX10q
GY10
GY10q
GZ10
GZ10q
2G10
2G11
G12
GX12
G13
2G13
2GX13
G16d
G16t
GU16d/GX16d
GY16
G17q-7, GX17q-7 & GY17q-7
G17.5t-1
G20
G22
GY22
G23
GX23
G24, GX24 & GY24
G32, GX32 & GY32
G38
GX38q
G53
GX53
Pre-focus lamp
PGJ5
P11.5d
PG12 & PGX12
PGZ12
PG13 & PGJ13
P13.5s
PX13.5s
GRZ10d
GRZ10t
PG18.5d
PGJ19
PGJY19
P20d, PX20d, PY20d & PZ20d
PG20 & PGU20
P22d & PX22d
PG22-6.35
PK22s
PKX22s
P23t
P26s
PX26d
P26.4t & PJ26.4t
P28s
P29t
P30s-10.3
P32d & PK32d
P36
P38s
P38t
P40s
P43t
PX43t
PY43d
PZ43t
P45t
P46s
Miscellaneous cap
R7s
RX7s
R17d
SX4s/4
SY4s/7
S5.7s
SX6s
SV7
SV8.5
S14
S15s & S19s
SK15s
P14.5s
P18s
W2.5x16
WU2.5x16
WX2.5x16
WY2.5x16
WZ2.5x16
W3x16d & WX3x16d
W3x16q, WX3x16q & WY3x16q
WZ3x16q
W2x4.6d
W2.1x9.5d
W3.3x10.4d
WP4x9d
W4.3x8.5d
W10.6x8.5d
X511
Flashcube/CubeFlash
MagicubeTypeX
indicates lamp is not allowed in China for domestic use.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 2797-2008_English be delivered?Answer: Upon your order, we will start to translate GB 2797-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 2797-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 2797-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 2797-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 2797-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|