US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 27900-2011: Firemen special call unit Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 27900-2011 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Firemen special call unit
| Valid |
GB 27900-2011
|
PDF similar to GB 27900-2011
Basic data | Standard ID | GB 27900-2011 (GB27900-2011) | | Description (Translated English) | Firemen special call unit | | Sector / Industry | National Standard | | Classification of Chinese Standard | C85 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 15,140 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-06-01 | | Quoted Standard | GB/T 191; GB/T 2423.1; GB/T 2423.2; GB/T 2423.4; GB/T 2423.5; GB/T 2423.8; GB/T 2423.10; GB 3836.1 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 23 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies the firemen hailing device terminology and definitions, models, technical requirements, test methods, inspection rules, marking, packaging, transport and storage. This standard applies to fire and rescue firefighters firemen carry side process call for help. |
GB 27900-2011: Firemen special call unit---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Firemens special call unit
ICS 13.220.10
C85
National Standards of People's Republic of China
Firefighters HuJiuQi
Issued on. 2011-12-30
2012-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Model 1
5 2 Technical Requirements
6 Test methods 5
7 Inspection rules 9
8 signs, packaging, transportation and storage 11
Foreword
The standard Chapter 5, Chapters 7 and 8.1.1 are mandatory, the rest are recommended.
This standard is prepared in accordance with GB/T 1.1-2009 given rules.
The standard proposed by the People's Republic of China Ministry of Public Security.
This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized.
This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security.
Drafters of this standard. Shen Jian Min Zhou, shining horse, Zhang Yan, Li Rui Kun, Li Yu Zhang.
This standard is the first release.
Firefighters HuJiuQi
1 Scope
This standard specifies the firefighters HuJiuQi terms and definitions, models, technical requirements, test methods, inspection rules, marking, packaging, transportation
And storage.
This standard applies to firefighters in fire fighting and rescue process be worn fireman HuJiuQi (hereinafter referred to as HuJiuQi).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs
GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.4 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h 12h
cycle)
GB/T 2423.5 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock
GB/T 2423.8 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall
GB/T 2423.10 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB 3836.1 explosive atmospheres - Part 1. General requirements for equipment
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Allow rest time permissiblestatictime
HuJiuQi from a quiescent state until the pre-alarm sound signal preset time.
3.2
Pre-alarm time pre-alerttime
HuJiuQi since the issuance of pre-alarm signal to sound an alarm sound signal time.
3.3
Continuous alarm time continuousalerttime
The duration of the alarm emits an acoustic signal for help.
4 Model
HuJiuQi Model preparation should meet the following requirements.
R fireman personal equipment
HJ
HuJiuQi
Continuous alarm time (min)
SOS function code (T represents a communication function HuJiuQi,
No communication HuJiuQi omitted)
/ □
Enterprises modified code (A, B,)
Example 1. RHJ300/A indicates continuous alarm time is A type of firefighters HuJiuQi 300min.
Example 2. RHJ240T/B indicates continuous alarm time 240min communication type B type HuJiuQi firefighters.
5 Technical requirements
5.1 General Requirements
5.1.1 call for help should be able to work properly in the following use environment.
a) a temperature of -25 ℃ ~ 70 ℃;
b) Relative humidity 30% to 93%;
c) atmospheric pressure is 86kPa ~ 106kPa.
5.1.2 call for help should be provided with means to wear, and it works fine when any work position.
5.1.3 HuJiuQi power supply should be used rechargeable batteries.
5.1.4 call for help should be set battery charge and discharge protection circuit.
5.2 Functional requirements
5.2.1 Pre-alarm function
When the call for help is in automatic working condition, it should have the pre-alarm function. When a still longer than the permissible time still, should be issued quickly
Intermittent pre-alarm sound signal. During the pre-alarm, HuJiuQi work orientation changes or HuJiuQi for rate of not less than 5m/s flat
When uniform motion, pre-alarm sound signal should be immediately released.
5.2.2 automatic alarm function
When the call for help is in automatic working condition, when a still longer than the permissible time of static and pre-alarm time and shall be issued a continuous alarm
Acoustic signal and position-indicating strobe signal. During the alarm, the alarm sound signal and position-indicating strobe signal for help is not working
Effect of azimuthal variations or changes in the rate of movement, and should only be manually removed.
5.2.3 Manual alarm
When the call for help is in manual operation, and automatic alarm function shall be given the same alarm sound signal and position-indicating strobe signal.
During a manual alarm, alarm sound signal and the position-indicating strobe signal for help should not be working or orientation change motion rate variation
influences.
5.2.4 Low voltage alarm function
When HuJiuQi supply voltage of the battery is below 80% of rated voltage, different from the pre-alarm shall be given a slow intermittent audible signal warning
Acoustic or optical signals.
5.2.5 Communication Function
Communication type HuJiuQi in alarm should sound a warning signal and the position-indicating strobe signal. At the same time, we should be able to call for help send
Radio signal receiving terminal to be identified, and can receive and identify signals transmitted from the receiving terminal.
5.2.6 switch
HuJiuQi should be set to "Off - Manual - Automatic" switch. Switch should be flexible, reliable, durable, and anti malfunction structure.
5.3 Performance Requirements
5.3.1 allow rest time
HuJiuQi still allow time should 30s ± 2s.
5.3.2 Pre-alarm time
HuJiuQi Pre-alarm time should be 15s ± 2s.
5.3.3 Pre-alarm sound level intensity
HuJiuQi pre-alarm sound level intensity should not be less than 80dB.
5.3.4 alarm sound level intensity
SOS alarm sound level intensity should not be less than 100dB.
5.3.5 Low voltage alarm sound level intensity
HuJiuQi low voltage alarm sound level intensity should not be less than 65dB.
5.3.6 Continuous working time
HuJiuQi continuous working time should meet the following requirements.
a) continuous boot time is not less than 24h;
b) continuous alarm time is not less than 240min.
5.3.7 Quality
HuJiuQi quality should not exceed 300g (including battery).
5.3.8 Appearance
HuJiuQi structure should be complete, the surface should not have obvious spots, bubbles, cracks and scratches.
5.3.9 proof performance
Proof performance HuJiuQi shall comply with the provisions of GB 3836.1.
5.3.10 insulation
HuJiuQi insulation shall meet the following requirements.
a) between the positive and negative electrodes and shell insulation resistance in normal environmental conditions should not be less than 50MΩ;
b) between the positive and negative electrodes and shell insulation resistance after damp heat test shall not be less than 10MΩ.
5.3.11 Waterproof
HuJiuQi placed in a water depth of 1.5m containers within 2h, should penetrate the anhydrous HuJiuQi, call for help should be able to work properly.
5.3.12 weatherability environmental performance
SOS shall be subjected to the climate and environment test specified in Table 1, after each test shall comply with the requirements of 5.3.1 ~ 5.3.4. Alternating hot and humid
After also meet 5.3.10b) requirements.
Table 1 Climate Experiment
Name of test Test conditions working conditions
High Temperature Test temperature. 70 ℃ ± 2 ℃ Duration. 2h energized
Low Temperature Test temperature. -25 ℃ ± 2 ℃ Duration. 2h energized
Damp heat test
temperature
Rose to 25 ℃ ± 3 ℃
40 ℃ ± 2 ℃
40 ℃ ± 2 ℃
40 ℃ ± 2 ℃ dropped
25 ℃ ± 3 ℃
Relative humidity of 85% to 93% 90% 93% 85% to 93%
Duration 3h 9h 12h
Energized state
High-temperature storage test temperature. 70 ℃ ± 2 ℃ Duration. 16h recovery time at room temperature. 12h-energized state
Low temperature storage test temperature. -40 ℃ ± 2 ℃ Duration. 16h recovery time at room temperature. 12h-energized state
5.3.13 Resistance to mechanical environmental performance
SOS specified in Table 2 shall be subjected to various mechanical environment test, after the test shall meet the following requirements.
a) There should be no mechanical damage and tighten loose parts;
b) shall comply with the requirements of 5.3.1 ~ 5.3.4.
Table 2 Mechanical environmental testing
Name of test Test conditions working conditions
Vibration (sinusoidal) test
Frequency range of 10Hz ~ 150Hz
1g acceleration amplitude
Scanning rate of 1 octave/min
Number of axes 3
Each axis scanning cycles 20
Energized state
Impact test
Peak acceleration 5g
11ms pulse duration
Half-sine pulse waveform
Axial number 6
Each number axially continuous impact of the number 3
Energized state
Free drop test
Drop height 1.5m
4 Number of drops
Energized state
5.3.14 transmit frequency
Communication type distress transmitter frequency should comply with State Radio Regulatory Commission specified operating frequency band or frequency and requirements. RF Hair
Rate error should not exceed ± 25kHz.
5.3.15 Frequency Stability
Communication type HuJiuQi frequency stability should be less than ± 2.5 × 10-6.
5.3.16 receiver sensitivity
HuJiuQi communication type receiver sensitivity should not exceed 0.5μV (SNR 12dB).
5.3.17 communication distance
Communication type HuJiuQi effective communication distance (open area) should not be less than 800m.
5.3.18 emission luminance
HuJiuQi emission luminance not less than 300cd/m2.
5.3.19 simulated smoke environment azimuth indicating performance
Smoke in the environment, you should be able to instruct HuJiuQi orientation.
6 Test methods
6.1 test environment condition
If there is no description of the relevant provisions, the test shall be under the following normal atmospheric conditions.
a) a temperature of 15 ℃ ~ 35 ℃;
b) Relative humidity 45% to 75%;
c) atmospheric pressure is 86kPa ~ 106kPa.
6.2 Test instruments
Test instruments include.
a) stopwatch. accuracy no less than 0.1s;
b) sound level meter. Resolution no less than 1dB;
c) Power supply. accuracy no less than 1%;
d) shake your device. call for help can be fixed at the top, shaking a continuous period of time of less than 25s;
e) plane motion means. You can call for help in fixing it, can not be less than 5m/s uniform motion;
f) full-band radio wave shielding room;
g) RF frequency meter;
h) a high frequency signal generator;
i) the audio signal measurement instrument;
j) luminance meter. accuracy no less than 5%.
6.3 Alarm function test
So HuJiuQi respectively in the automatic and manual operation, check the alarm function for help.
6.4 Low-voltage warning function tests
The regulated power supply circuit access HuJiuQi, slowly adjust the power supply voltage is lower than call for help until the battery rated voltage 80%
When, for help checking low voltage alarm function.
6.5 Communication function tests
Type of the communication is in alarm state for help, check the communication type HuJiuQi transmitter function. Elimination Communication type SOS alarm state, it at
In automatic mode, the transmission signal receiving terminal, check the communication type HuJiuQi reception.
6.6 switch inspection
Check and operation switch, check the conversion.
6.7 still allows time trial
HuJiuQi in a stationary state, will switch to "Auto" position and start the stopwatch to start pre-alarm, stop the clock, recording
Stopwatch measurement.
6.8 Pre-alarm Time Trial
HuJiuQi in a stationary state, will switch to "Auto" position, when starting pre-alarm, start the stopwatch, alarm to start, stop,
Time, measurements were recorded stopwatch.
6.9 Pre-alarm sound level intensity test
Under the condition of not more than 30dB of ambient noise, so that generates a pre-alarm call for help, for help from the center in the horizontal direction is on 1m distance
Used for help sound level meter measurement, the maximum measured sound intensity level is a pre-alarm sound level intensity.
6.10 alarm sound level intensity test
Under the condition of not more than 30dB of ambient noise, so HuJiuQi alarm in the horizontal direction away from the center for help 3m far from being on call
Used to save the sound level meter, the measured intensity is the maximum sound level alarm sound level intensity.
6.11 Low voltage alarm sound level intensity test
Under the condition of not more than 30dB of ambient noise, so call for help is in a low voltage state, away from the center of the horizontal direction HuJiuQi 1m distance
N Used to call for help measure the sound level meter, measured maximum sound level intensity is low voltage alarm sound level intensity.
6.12 continuous boot time test
Shake your device to call for help or placed flat on the motion device, switch to "Auto" position, start time, issues a call for help to a low voltage
Alarm signals, stop time, record the measured value.
6.13 continuous alarm time trial
The call for help switch to "manual" position, start the timer and call for help from the center in the horizontal direction to call for help 3m far from being sound Used
When the alarm level measured sound level intensity to the alarm sound level intensity lower than 100dB, stop time, record the measured value.
6.14 Quality Test
With an accuracy of not less than 1g universal measuring instrument of mass HuJiuQi.
6.15 Visual inspection
HuJiuQi visual appearance.
6.16-proof performance test
HuJiuQi proof performance test in accordance with the provisions of GB 3836.1 performed.
6.17 insulation test
With 500V DC megger the battery positive and negative pressure HuJiuQi insulation resistance between the shell.
6.18 waterproof performance test
Call for help is not in working condition, which regards water depth of 1.5m within the container, start time, when the test reaches 2h, remove, rub
Dry surface, turn for help to check.
6.19 High Temperature Test
Shake your device to call for help placed on 5.3.12 by high temperature test conditions and GB/T 2423.2 Test provisions.
6.20 Low temperature test
Placed the call for help shake your device, press the low temperature test conditions 5.3.12 and GB/T 2423.1 Test provisions.
6.21 Damp heat test
5.3.12 Press alternating hot and humid conditions and test GB/T 2423.4 regulations test, test after test insulation.
6.22 high temperature storage test
Press 5.3.12 high temperature storage test conditions and GB/T 2423.2 Test provisions.
6.23 low temperature storage test
5.3.12 by low temperature storage test conditions and GB/T 2423.1 Test provisions.
6.24 Vibration Resistance Test
The HuJiuQi upright fixed to the vibration table, press (sinusoidal) Test conditions and GB/T 2423.10 regulations 5.3.13 of vibration
test.
6.25 Impact test
The HuJiuQi upright fixed on the impact of the stage, according to 5.3.13 in the impact test conditions and GB/T 2423.5 Test provisions.
Free drop test 6.26 resistance
According to 5.3.13 in the free drop test conditions and GB/T 2423.8 regulations are tested for the smooth concrete countertops
mesa.
6.27 emission frequency measurement
Emission frequency measurement should be full-band radio wave shielding room (chamber) is carried out. By connecting the measuring instrument shown in Figure 1, so HuJiuQi
Alarm, measuring their radio frequency emission.
FIG. 1 transmit frequency, frequency stability measurement diagram
6.28 Frequency Stability Measurement
Frequency stability measurements should be full-band radio wave shielding room (chamber) is carried out. By connecting the measuring instrument shown in Figure 1, so call for help
Generates alarms were measured at ± 2 ℃ -25 ℃, emit radio frequency waves 25 ℃ ± 2 ℃, 70 ℃ ± 2 ℃ when.
6.29 receiver sensitivity measurements
Receiver sensitivity measurements should be in full-band radio wave shielding room (chamber) is carried out. As shown in Figure 2 to connect the measuring instrument. High regulation
Frequency signal generator output signal frequency of the transmission frequency of distress, while adjusting the amplitude of the output signal when the audio (noise) signal meter to determine
Get SNR 12dB, the recording output signal amplitude.
Figure 2 receiver sensitivity measurements
6.30 Communication distance test
Tests carried out at the open area, so that the communication type SOS alarm, record type HuJiuQi communication with the communication terminal receives the maximum normal communication distance
from. Elimination Communication type SOS alarm state, it is in automatic mode, the terminal receiving the transmitted signal, recording communication with the communication interface type for help
The maximum income from the normal communication terminal.
6.31 emission luminance test
HuJiuQi emission luminance distribution of test points according to claim 3, with an accuracy not less than ± 5% at a luminance meter HuJiuQi emitting surface 5m
The distance measurement.
Figure 3 emission luminance test chart
6.32 simulated smoke environment orientation recognition performance test
Laboratory area should not be less than 4m × 5m, is fuming fuming, gas concentration to the naked eye can not recognize objects within 1m prevail, will call
Save placed at a distance from the observation point 3m observed HuJiuQi orientation.
7 Inspection rules
7.1 Type inspection
7.1.1 Type inspection at one of the following situations.
--- When setting new product trial;
--- Product design, material, structure, process the larger changes;
--- Normal production at least two years;
--- Discontinued one year to resume production;
--- National quality supervision agency type inspection requirements.
7.1.2 Type test samples shall be randomly inspected at the factory products, sample number is nine.
7.1.3 type test items, test procedures and substandard classification in accordance with Table 3.
7.1.4 The test results appear one of the following conditions that is deemed to have failed.
--- Class A failure occurred;
--- Appears greater or equal to two Class B failed;
--- Appears a Class B failed, at least two simultaneous Class C failed.
7.2 factory inspection
7.2.1 Each test should call for help after passing the factory, and should be accompanied by product certification.
7.2.2 Each HuJiuQi factory inspection items should include 5.2,5.3.1 ~ 5.3.4,5.3.7,5.3.8,5.3.10a), 5.3.18, communication
It should also include the type HuJiuQi 5.3.14 - 5.3.17.
7.2.3 If a test result does not meet this standard, the product delivery inspection station to be ineligible.
Table 3 type test items, test procedures and substandard classification
Test items
Sample number substandard classification
1 2 3 4 5 6 7 8 9 ABC
Alarm √ √ √ does not meet the standard requirements - -
Low-voltage alarm function √ √ √ does not meet the standard requirements - -
Communication a √ √ √ does not meet the standard requirements - -
√ √ √ Check the switch does not meet the standard requirements - -
Allow rest time/min √ √ √ does not meet the standard requirements - -
Pre-alarm time/min √ √ √ does not meet the standard requirements - -
Pre-alarm sound intensity/dB √ √ √ does not meet the standard requirements - -
Alarm sound intensity/dB √ √ √ does not meet the standard requirements - -
Low voltage alarm sound intensity/dB √ √ √ < 50 < 65 and ≥50 -
Continuous uptime/h √ √ √ < 20 < 24 and ≥20 -
Continuous alarm time/min √ √ √ < 200 < 240 and ≥200 -
Quality/g √ √ √ > 350 ≤350 and > 325 ≤325 and > 300
Appearance √ √ √ √ √ √ √ √ √
There are obvious spots,
Bubbles, cracks, flaws
There are the obvious spots,
Bubbles, scars
Slight spots,
Bubbles, scars
√ proof performance does not meet the standard requirements - -
Insulation /
MΩ
Normally √ √ √ < 40 - -
After the damp heat test √ √ √ < 5 - -
Waterproof √ √ √ does not meet the standard requirements - -
Weather
Environmental performance
High-temperature test √ √ √
Low temperature test √ √ √
Damp heat test √ √ √
High temperature storage test √ √ √
Low temperature storage test √ √ √
Does not meet the standard requirements -
Resistance to mechanical
Environmental performance
Vibration (sinusoidal) test √ √ √
Impact test √ √ √
Free drop test √ √ √
Does not meet the standard requirements -
Transmitting frequency a/MHz √ √ √ does not meet the standard requirements - -
Frequency stability of a/× 10-6 √ √ √ does not meet the standard requirements - -
Receiving sensitivity a/μV √ √ √ does not meet the standard requirements - -
Communication from the a/m √ √ √ does not meet the standard requirements - -
Emission luminance/(cd/m2) √ √ √ does not meet the standard requirements - -
Simulated smoke environment √ √ √ azimuth indicating performance does not meet the standard requirements - -
Product mark √ √ √ √ √ √ √ √ √ does not meet the standard requirements - -
This test is a project for a distribution type HuJiuQi.
8 signs, packaging, transportation and storage
8.1 mark
8.1.1 Product Marking
The product shall be marked with the following.
a) Product name, model;
b) production plant name;
c) the date of manufacture;
d) proof mark;
e) the implementation of the standard code.
8.1.2 Package mark
The packaging shall be marked with the following.
a) manufacturer's name and address;
b) the product name, model number, standard number;
c) the date of manufacture;
d) shall be marked "Handle with care", "prevent rain" signs, and in line with GB/T 191 with the relevant provisions.
8.2 Packaging
After each call for help Used plastic packaging into packing carton, along with product certification and instructions for use.
8.3 Transportation and storage
8.3.1 HuJiuQi during transportation to avoid stress, collisions and rain.
8.3.2 HuJiuQi should be stored in a place dry, ventilated, non-corrosive chemicals.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 27900-2011_English be delivered?Answer: Upon your order, we will start to translate GB 27900-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 27900-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB 27900-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|