US$209.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13917.1-2009: Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 1: Spray fluid Status: Valid GB/T 13917.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 13917.1-2009 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 1: Spray fluid
| Valid |
GB/T 13917.1-2009
|
| GB 13917.1-1992 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Efficacy test methods of public health insecticides for pesticids registration. Method of laboratory efficacy test for spray
| Obsolete |
GB 13917.1-1992
|
PDF similar to GB/T 13917.1-2009
Basic data | Standard ID | GB/T 13917.1-2009 (GB/T13917.1-2009) | | Description (Translated English) | Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 1: Spray fluid | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | B17 | | Classification of International Standard | 65.100 | | Word Count Estimation | 9,998 | | Date of Issue | 2009-03-27 | | Date of Implementation | 2009-10-01 | | Older Standard (superseded by this standard) | GB 13917.1-1992; GB/T 17322.1-1998 | | Regulation (derived from) | National Standard Approval Announcement 2009 No.4 (Total No.144) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the Efficacy test methods and evaluation criteria propellant. This section applies to insecticide sprays and health products after dilution with water or oil used in the registration of pesticides on health pest mosquitoes, flies, cockroaches, ants, flea spray or residual spraying determination and evaluation of efficacy. |
GB/T 13917.1-2009: Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 1: Spray fluid ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration Part 1. Spray fluid
ICS 65.100
B17
National Standards of People's Republic of China
Replacing GB 13917.1-1992, GB/T 17322.1-1998
Health insecticides for pesticide registration
Laboratory efficacy test methods and evaluation
Part 1. propellant
Posted 2009-03-27
2009-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 13917 "health insecticides for pesticide registration indoor efficacy test and evaluation" in 10 sections.
--- Part 1. propellant;
--- Part 2. Aerosol;
--- Part 3. Smoke and smoke film;
--- Part 4. mosquito coils;
--- Part 5. Electric Coil;
--- Part 6. electric mosquito liquid;
--- Part 7. Bait;
--- Part 8. powders, pencils;
--- Part 9. repellent;
--- Part 10. Analog scene.
This section GB/T Part of 113,917.
This Part replaces GB 13917.1-1992 "health insecticides for pesticide registration indoor efficacy test for spray indoor efficacy test
Setting Method "and GB/T 17322.1-1998" health insecticides for pesticide registration indoor efficacy evaluation propellant. "
This part of GB 13917.1-1992 GB/T 17322.1-1998 and compared to the main changes are as follows.
--- And the GB 13917.1-1992 GB/T 17322.1-1998 merged, so that methods and evaluation criteria to be in the same
Reflect the application more convenient;
--- Provisions on the revision of the standard test insect. using laboratory reared insects susceptible strains of the standard test;
--- Modified and clarified the test insects age;
--- Test insects increases the ants and fleas;
--- Modify the test instrument, the description of the instrument related changes;
--- Clear residual spraying test three contact surface of the material;
--- Modify the contents of the relevant standard methods, such as dosage, etc;
--- Standardized standard way of expression;
--- Increasing the specific requirements of the test results and test reports prepared.
This section proposed by the People's Republic of China Ministry of Agriculture.
This part of the jurisdiction of the Ministry of Agriculture.
This section was drafted by. the Ministry of Agriculture, Institute of Microbiology and Epidemiology Academy of Sciences.
The main drafters of this section. Taoling Mei, Wang Xiaojun, Zhang Jintong, n-octyl, Lili Ji, Huangqing Zhen, Wu Shixiong.
This part of the standard replaces the previous editions are.
--- GB 13917.1-1992;
--- GB/T 17322.1-1998.
Health insecticides for pesticide registration
Laboratory efficacy test methods and evaluation
Part 1. propellant
1 Scope
GB/T 13917 provisions of this part of the Efficacy test methods and evaluation criteria propellant.
This section applies to sprays and insecticides products after diluted with water or oil when used in pesticide registration of health pest mosquitoes, flies,
Cockroaches, ants, fleas spray or residual spraying efficacy measured and evaluated.
2 for the test material
Using laboratory reared insects susceptible strains of the standard test.
Mosquito 2.1
Region), after the emergence of the first 3 days to 5 days without blood-sucking female adults.
2.2 Flies
2.3 Cockroach
2.4 Ants
Flea 2.5
Half and half.
3 Equipment
3.1 nozzle
Drain mandrel diameter 0.4mm, nozzle diameter 1.2mm, 20mm long with a tail end of a plastic tube with a flat head 12 Injection
Needle attached.
3.2 The atomizing barrel (FIG. 1)
Colorless transparent cylinder (the A), the chassis (B) the diameter of 250mm, 100mm in radius grooving of concentric circles, the groove depth of 1mm, a cylindrical groove width
Wall thickness prevail, the cylinder (A) and the chassis (B) snap fit. The chassis has a 20mm diameter hole, plugged with a rubber stopper (C).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13917.1-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 13917.1-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 13917.1-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13917.1-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 13917.1-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13917.1-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|