US$599.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 938-2012: General technical requirements for finger vein recognition devices in security systems
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GA/T 938-2012 | English | 599 |
Add to Cart
|
4 days [Need to translate]
|
General technical requirements for finger vein recognition devices in security systems
| |
GA/T 938-2012
|
PDF similar to GA/T 938-2012
Basic data Standard ID | GA/T 938-2012 (GA/T938-2012) | Description (Translated English) | General technical requirements for finger vein recognition devices in security systems | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | Classification of Chinese Standard | A91 | Classification of International Standard | 13.310 | Word Count Estimation | 17,182 | Date of Issue | 2012-12-26 | Date of Implementation | 2013-03-01 | Quoted Standard | GB/T 191-2008; GB/T 2421.1-2008; GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.3-2006; GB/T 2423.8-1995; GB/T 2423.10-2008; GB/T 5080.7-1986; GB/T 5271.14-2008; GB/T 17626.2-2006; GB/T 17626.3-2006; GA/T 893-2010; GA/T 939; GA/T 940; ISO/IEC 19794.4 | Regulation (derived from) | Announcement on Publication of Public Safety Industry Standard; Industry Standard Record Announcement No. 3 of 2013 (No. 159) | Issuing agency(ies) | Ministry of Public Security | Summary | This standard specifies the terminology and definitions, technical requirements, test methods, inspection rules, and packaging, marking, transport, storage, etc., of finger vein collection and identification devices used in the system for finger vein iden |
GA/T 938-2012: General technical requirements for finger vein recognition devices in security systems ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General technical requirements for finger vein recognition devices in security systems
ICS 13.310
A91
People's Republic of China Public Security Industry Standards
Security finger vein identification applications
General technical requirements
Issued on. 2012-12-26
2013-03-01 implementation
People's Republic of China Ministry of Public Security
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 2 Technical Requirements
Test Method 4 5
6 7 inspection rules
7 signs, packaging, transportation and storage 8
Appendix A (normative) function Checker 10
Appendix B (normative) Performance Test Function Description 11
Annex C (normative) resolution, distortion and maximum dynamic range of gray levels 12 Test Method
Annex D (normative) judgments based fault classification and 13
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. The issuing authority of this article does not assume responsibility for the identification of these patents.
The Standard Appendix A, Appendix B, Appendix C, Appendix D is a normative appendix.
The Standard Technical Committee biometric identification applications Technical Committee (SAC/by the national security and alarm system standardization
TC100/SC2) and focal points.
This standard was drafted. Beijing in the security shield technology development company, the Ministry of Public Security and Police Electronic Products Quality Inspection Center, Tsinghua University
Science, Shenzhen control biometric Technology Co., Ltd., the first Ministry of Public Security Institute.
The main drafters of this standard. Hou Hongchuan, HE Lan, Qi Wei Wei, Yin Desen Li Shan well, Chen Shukai, Ma Huimin, Sun Xi, Hu Ang Lee as incense.
Security finger vein identification applications
General technical requirements
1 Scope
This standard specifies the terms and definitions of security refers vein recognition application system acquisition and middle finger vein identification equipment, technical requirements, test side
Method, inspection rules and packaging, labeling, transportation and storage.
This standard applies to security refers to the development, production and testing vein recognition application system acquisition and middle finger vein identification device.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including all amendments), applicable to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 2421.1-2008 Environmental testing for electric and electronic products and Overview Guide
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test
GB/T 2423.8-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB/T 5080.7-1986 Equipment reliability testing efficiency constant failure rate assumption under the MTBF verification tests
Program
GB/T 5271.14-2008 Information technology - Vocabulary Part 14. Reliability, maintainability and availability
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 electromagnetic compatibility test and measurement technology RFEMS test
GA/T 893-2010 biometric security application terminology
GA/T 939 security finger vein recognition algorithm application system evaluation method
GA/T 940 security finger vein image recognition application system technical requirements
Fingerprint image data. Format Part 4 ISO /IEC 19794.4 Information technology - Biometric data interchange
3 Terms and Definitions
ISO /IEC 19794.4, GA/T 939, GA/T 940 and GA/T 893-2010 defined by the following terms and definitions apply
This document.
3.1
Finger vein template fingerveintemplate
Finger vein data recording features and related information.
3.2
Finger vein recognition fingerveinrecognition
It refers to the use of vein individual identification process, including the finger vein authentication and the finger vein identification.
3.3
Finger vein verification fingerveinverification
A finger vein features and a designated finger vein template matching, test its process from the same individual, that 1.1 recognition.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 938-2012_English be delivered?Answer: Upon your order, we will start to translate GA/T 938-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA/T 938-2012_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 938-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|