HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (11 Oct 2025)

GA/T 882-2014 English PDF

US$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GA/T 882-2014: Technical requirements for trial synchronous recordin system

GA/T 882: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA/T 882-2014English319 Add to Cart 3 days [Need to translate] Technical requirements for trial synchronous recordin system GA/T 882-2014
GA/T 882-2010English439 Add to Cart 3 days [Need to translate] Technical requirement for digital trial recording system Obsolete GA/T 882-2010

PDF similar to GA/T 882-2014


Standard similar to GA/T 882-2014

GA/T 424   GA 1210   GA 1051   GA/T 819   GA/T 985   GA/T 591   

Basic data

Standard ID GA/T 882-2014 (GA/T882-2014)
Description (Translated English) Technical requirements for trial synchronous recordin system
Sector / Industry Public Security (Police) Industry Standard (Recommended)
Classification of Chinese Standard A92
Classification of International Standard 13.310
Word Count Estimation 9,992
Date of Issue 2014-10-21
Date of Implementation 2014-10-21
Older Standard (superseded by this standard) GA/T 882-2010
Quoted Standard GB/T 191-2008; GB/T 2423.57-2008; GB/T 2423.58-2008; GB/T 2423.102-2008; GB/T 4857.5-1992; GB/T 5080.7-1986; GB 9254-2008; GB 16796-2009
Regulation (derived from) Announcement of the Ministry of Public Security (2015.02.16); Industry Standard Record Announcement No. 4 of 2015 (No. 184 of the General Administration of Industrial Safety of the People Republic of China)
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the system structure, requirements, test methods, face inspection rules, marking, packaging, transportation and storage of interrogation synchronous recording and recording system. This standard applies to interrogation synchronous

GA/T 882-2014: Technical requirements for trial synchronous recordin system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical requirements for trial synchronous recording system ICS 13.310 A92 People's Republic of China Public Safety Industry Standards Replaces GA/T 882-2010 Interrogation synchronous audio and video recording system technical requirements Released on.2014-10-21 2014-10-21 Implementation Published by the Ministry of Public Security of the People's Republic of China Interrogation synchronous audio and video recording system technical requirements

1 Scope

This standard specifies the system structure, requirements, test methods, inspection rules, marking, packaging, transportation and store. This standard applies to interrogation synchronous audio and video recording systems.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191-2008 Graphical signs of packaging, storage and transportation GB/T 2423.57-2008 Environmental Testing of Electrical and Electronic Products Part 2.Test Methods Test Ei. Shock Impulse Response Spectral synthesis GB/T 2423.58-2008 Environmental testing of electrical and electronic products - Part 2.Test methods Test Fi. Vibration mixed mode GB/T 2423.102-2008 Environmental testing of electrical and electronic products - Part 2.Test method test. Temperature (low temperature, high temperature)/ Low air pressure/vibration (sinusoidal) combined GB/T 4857.5-1992 Drop test method for packaging and transportation packages GB/T 5080.7-1986 Equipment reliability test - verification test of failure rate and mean time between failures under the assumption of constant failure rate test plan GB 9254-2008 Radio Disturbance Limits and Measurement Methods for Information Technology Equipment GB 16796-2009 Safety requirements and test methods for safety precaution and alarm equipment

3 System structure

The interrogation synchronous recording and video recording system is composed of acquisition, transmission, display and playback, storage and control equipment. a) The acquisition equipment consists of auxiliary equipment such as color cameras, pickups and brackets; b) The transmission equipment consists of auxiliary equipment such as optical fiber, network cable, video cable, audio cable, communication control cable; c) Display playback equipment consists of a display or monitor and speakers; d) The storage device consists of devices such as CD-ROM and hard disk; e) Control equipment consists of camera and pickup control equipment, power supply and communication interface.

4 Requirements

4.1 Appearance requirements The appearance of the system should be neat and tidy, and the surface should be free from obvious defects in the production process. 4.2 Structural Requirements The operation of switches, buttons and knobs should be flexible and reliable, the parts should be tightened without loosening, the connectors should be able to be connected reliably, the indications should be correct, and the layout should be properly arranged. management, easy to operate. 4.3 Functional and performance requirements 4.3.1 Acquisition equipment 4.3.1.1 It has the function of real-time acquisition of interrogation sound and image. Real-time and clear capture of the voices and background of the interrogator and the person being interrogated Sound, real-time and clear collection of frontal mid-range and place panoramic images of the person being interrogated, including ambient temperature, humidity and time. 4.3.1.2 A digital camera with a resolution of 720P or 1080P should be used, and the minimum illumination is 0.5lx. 4.3.1.3 Cardioid directional pickups are used, the sensitivity is -40dB±3dB, and the frequency response is 50Hz~15kHz. The signal-to-noise ratio is greater than 65dB, the dynamic range is greater than 96dB. 4.3.1.4 The audio sampling frequency of the system is 16kHz and 16bit quantization. 4.3.2 Transmission equipment 4.3.2.1 Between the acquisition equipment and the control equipment, the network cable, video cable, audio cable and signal control cable should be used to connect the equipment. To ensure the accuracy of sound, image quality and control signal. 4.3.2.2 Using MPEG-4, H.264, AAC and other audio and video real-time compression network video server technologies, the resolution of a single screen is greater than or equal to At 704 pixels × 576 pixels, and the transmission code stream is greater than or equal to 512kbit/s, it should be able to realize the webcasting, audio-text interaction, and communication of the interrogation process. Ask about the selection of live scenes. 4.3.3 Display playback device 4.3.3.1 Real-time and clear display of the frontal mid-shot and the site panorama image of the person being interrogated, including ambient temperature, humidity and time. 4.3.3.2 The audio and video of the interrogation can be played back clearly. The sound quality should not be distorted, and the sound playback should be synchronized with the video. 4.3.3.3 The resolution and interface of the display and playback equipment shall match those of the acquisition and control equipment. 4.3.3.4 It has the function of switching between single-screen and dual-screen display. 4.3.4 Storage Devices 4.3.4.1 It has the functions of real-time recording of interrogation audio and video with dual optical drives and real-time automatic storage of hard disk. There should be more than two video inputs, two independent Independent audio input, the encoding standard is MPEG-4, H.264, AAC. The resulting audio and video files can be played in a universal player. 4.3.4.2 With clock correction function. 4.3.4.3 It has the function of setting the title content of the case number, name, name of the interrogator, name of the person being interrogated, and the location of the interrogation. Inside the title After the content is set, the title is automatically generated and superimposed on the video screen. 4.3.4.4 It has the function of calculating the hash value of the recorded and stored audio and video data, and combines it with the audio and video data in the form of a separate file. stored together. 4.3.4.5 Real-time detection and display of the remaining usage time of the storage medium capacity. When it is less than 30min, a prompt should be given. should have audio and video Data loss, abnormal alarm and disposal method prompt function. 4.3.4.6 In the process of CD burning and real-time automatic storage on hard disk, it should have the key mark function. 4.3.4.7 The frame rate of the video stored on the hard disk is greater than or equal to 25fps, and the image resolution is greater than or equal to 704 pixels × 576 pixels. 4.3.4.8 For audio and video data stored in CD-ROM and other media, the encoding standard shall be MPEG-4, H.264, AAC, and the image resolution shall be greater than or equal to 704 pixels x 576 pixels. 4.3.4.9 The CD recording should be completed within 5 minutes after the interrogation. When the disc recording fails, a prompt and clear prompt "Burning" should be displayed on the display. Failed”, prompting to replace the faulty disc. After the disc is replaced, the audio and video data stored in the hard disk can be automatically supplemented and recorded. 4.3.4.10 On the premise of ensuring the quality of audio and video recordings, a CD should be able to record 4 hours of audio and video data. 4.3.4.11 It has the function of automatic disc sealing. 4.3.5 Control equipment 4.3.5.1 It has the function of adjusting and controlling the focal length of the main camera lens and the gain of the pickup. 4.3.5.2 The lens control shall have the functions of zoom, auto focus and aperture setting. 4.4 Other requirements 4.4.1 System working environment. the temperature is -5℃~45℃, and the humidity is 15%~80%. 4.4.2 System working noise. ≤35dB. 4.4.3 Button response time. < 1s. 4.4.4 Power. AC (220±22)V, (50±2)Hz, < .200W. 4.5 Safety Requirements Should comply with the relevant provisions of GB 16796-2009. 4.6 Radio disturbance limit requirements The radio disturbance limit of the product shall meet the requirements of the conducted disturbance limit of Class A ITE power terminals in GB 9254-2008, see Table 1. 4.7 Reliability Requirements The reliability level of the product is measured by the mean time between failures (MTBF), and the unacceptable value of MTBF should be greater than or equal to 5000h.

5 Test methods

5.1 Basic principles The test methods specified in this standard apply to storage devices. The test should be carried out under the following conditions, climatic environment and reliability test except. a) Ambient temperature. -5℃~ 45℃; b) Relative humidity. 15%~80%; c) Atmospheric pressure. 86kPa~106kPa. 5.2 Visual inspection Visual inspection is carried out by visual inspection to determine whether the results meet the requirements of 4.1. 5.3 Structural inspection Check by visual inspection and hand test to determine whether the results meet the requirements of 4.2. 5.4 Functional check 5.4.1 Check item by item according to the stipulations in 4.3 to determine whether it complies with the stipulations. 5.4.2 The detection of hash value anti-counterfeiting authentication information shall be verified by a general test algorithm provided by a third party. 5.5 Performance Check 5.5.1 Adaptability of working power supply Adjust the working power supply, it should be able to work normally within ±10% of the nominal value. 5.5.2 Power consumption Use a power wattmeter, connect it to both ends of the load, and judge whether the result meets the requirements of 4.4.4. 5.6 Safety test method Test according to GB 16796-2009. 5.7 Radio disturbance limit test Carry out the test according to the provisions of GB 9254-2008.During the test, the functions of recording, video playback and network should work normally. 5.8 Environmental test 5.8.1 Principles The initial inspection and final inspection specified in each environmental test are carried out in accordance with the provisions of 4.1, 4.2 and 4.3 for appearance, structure and function. Inspection and key function inspection, the above inspections should be normal. 5.8.2 Low temperature test Carry out the test according to the provisions of GB/T 2423.102-2008.The test temperature is 0 °C, the test time is 2h, the power is turned on, and the recovery time is for 2h. 5.8.3 Storage and transportation low temperature test Carry out the test according to the provisions of GB/T 2423.102-2008.The test temperature is -20℃, no electricity is applied, and the test time is 16h. After the completion of the recovery under normal climatic conditions for 2 hours, the final test was carried out. In order to prevent the test sample from frosting and condensation during the test, the test sample is allowed to be sealed with polyethylene film and the test can be carried out if necessary. Put moisture absorbent in the sealing sleeve. 5.8.4 High temperature test 5.8.4.1 Working high temperature test Carry out the test according to the provisions of GB/T 2423.102-2008, the test temperature is 40 ℃, and the power is turned on for 2 hours to check whether the prototype works. Normal, the recovery time is 2h, and the final test is carried out. 5.8.4.2 High temperature test for storage and transportation Carry out the test according to the provisions of GB/T 2423.102-2008, the test temperature is 60 ℃, no electricity is applied, the test time is 2h, and the test is completed. After that, the recovery time was 2h, and the final detection was carried out. 5.8.5 Constant damp heat test 5.8.5.1 Constant damp heat test under operating conditions Carry out the test according to the provisions of GB/T 2423.102-2008, the test temperature is 40 ℃, the relative humidity is 40%~90%, Start the test, after 2h of test, power on and run during this period to test whether the work is normal, the recovery time is 2h, and the final test is carried out. 5.8.5.2 Damp heat test under storage and transportation conditions Carry out the test according to the provisions of GB/T 2423.102-2008, the test temperature is 40 ℃, the relative humidity is 90%~95%, before the test For the initial detection, the sample is not energized. After the test time of 48h, the recovery time after the test is 2h, and the final test is carried out. 5.8.6 Vibration test The test is carried out according to the provisions of GB/T 2423.58-2008, and the test sample is fixed on the vibration table according to the working position, and is not energized. Three mutually perpendicular axis directions vibrate. After the vibration test is completed, the detection is carried out. 5.8.7 Impact test Carry out the test according to the provisions of GB/T 2423.57-2008, do not energize, and make shocks in three mutually perpendicular axial directions respectively, and then The number is 3 times each. After the test, check. 5.8.8 Drop test of transport package Carry out the drop test according to the provisions of GB/T 4857.5-1992, select four sides, and drop each side once. Check after the test. 5.9 Reliability test 5.9.1 Test conditions The purpose of reliability testing is to determine the reliability level of a product under normal use conditions. During the test period, the comprehensive factors are specified as follows. a) Ambient temperature. -5℃~ 45℃; b) Relative humidity. 15%~80%; c) Working voltage. AC (220±22)V, (50±2)Hz. 5.9.2 Test plan According to the provisions of GB/T 5080.7-1986. 5.9.3 Test time It should continue until the total number of failures in the test set can be accepted or rejected according to the test plan, and the test time of multiple test samples Should be greater than or equal to half of the average test time for all samples tested. 5.9.4 Test samples The reliability test prototype shall be randomly sampled from the products that have passed the factory inspection, and the number shall be greater than or equal to 2 units. 5.9.5 Check test items During the test, the appearance, structure and function should be checked and tested 3 times. 5.9.6 Failure data 5.9.6.1 Correlation failure criteria Failures caused by the product itself are counted as associated failures. a) If any one of 5.8 fails to meet the requirements, one association failure will be counted; b) If the components are damaged, soldered, open circuit or short circuit, resulting in abnormal function operation, one associated failure will be counted; c) The accidental shutdown or abnormal operation of the program, but without any maintenance and adjustment, it can be restored to normal after restarting. 6.3 Factory inspection 6.3.1 The factory inspection shall be carried out by the quality inspection department of the product manufacturer. 6.3.2 For mass-produced or continuous-produced products, all ex-factory inspections shall be carried out. If all inspection items are qualified, it shall be judged as qualified; If any of the items are unqualified, the product is judged to be unqualified.

7 signs

7.1 Product identification The interrogation synchronous audio and video recording system should be marked with the manufacturer's name, address, product standard number, logo approval number, production date, trademark and model. 7.2 Electrical identification The part of the machine that is directly connected to the power grid should be marked with the nature of the power supply, rated power supply voltage (or operating voltage range), frequency and power consumption. 7.3 Packaging Identification The outer box of the product should have the following signs. a) Product name, model, manufacturer's name, address and implementation standard number; b) Trademark name, registered trademark pattern; d) Packing quality. kg; e) Maximum external dimensions of the package (L×D×H). mm; f) The graphic signs of packaging, storage and transportation such as moisture-proof, upward, handling with care, and stacking layers shall comply with the provisions of GB/T 191-2008.

8 packs

8.1 The product shall be packaged in one piece. 8.2 The product should have a firm package, and measures such as moisture-proof, dust-proof and shock-proof. 8.3 Products that pass the factory inspection shall be packaged together with the certificate of conformity, instruction manual, accessories, etc.

9 Transport

During transportation, it should be handled with care to prevent moisture, vibration and mechanical damage. 10 Save 10.1 When the product is stored, it should be stored in the original packing box. 10.2 The storage environment is normal temperature, the relative humidity is 15%~80%, keep ventilation and dryness, there should be no corrosive gas, no mechanical vibration shock and strong electromagnetic fields. 10.3 The storage period is generally 6 months.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GA/T 882-2014_English be delivered?

Answer: Upon your order, we will start to translate GA/T 882-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GA/T 882-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GA/T 882-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GA/T 882-2014?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA/T 882-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.