US$419.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 841-2021: General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry Status: Valid GA/T 841: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GA/T 841-2021 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry
| Valid |
GA/T 841-2021
|
GA/T 841-2009 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
General specification for trace narcotics/explosives detectors based on ion mobility spectrometry
| Obsolete |
GA/T 841-2009
|
PDF similar to GA/T 841-2021
Basic data Standard ID | GA/T 841-2021 (GA/T841-2021) | Description (Translated English) | General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | Classification of Chinese Standard | A91 | Word Count Estimation | 18,159 | Issuing agency(ies) | Ministry of Public Security |
GA/T 841-2021: General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry
ICS 13:310
CCSA91
People's Republic of China Public Safety Industry Standards
Replaces GA/T 841-2009
Trace quantities based on ion mobility spectrometry
General technical requirements for drug/explosive detectors
Published on 2021-09-17
2021-12-01 Implementation
Published by the Ministry of Public Security of the People's Republic of China
directory
Preface I
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Category 2
5 Technical requirements 2
6 Test method 8
7 Inspection rules 12
8 Marking, packaging, transportation and storage 14
foreword
This document is drafted in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents":
This document replaces GA/T 841-2009 "General technical requirements for trace drug/explosive detectors based on ion mobility spectrometry", and
Compared with GA/T 841-2009, in addition to structural adjustment and editorial changes, the main technical changes are as follows:
a) Modified terms, added detection limit, blank test, self-cleaning time, characteristic database (see 3:5, 3:7, 3:9, 3:11), deleted
Ion mobility spectrometer, trace drug/explosive detector, inhalation sampling, cold start (see 3:2, 3:3, 3:4, 3:6 of the:2009 edition), revised
Changed the swab sampling and detection rate (see 3:2, 3:3, 3:5 and 3:9 of the:2009 edition);
b) Modified the appearance requirements [see 5:1, 5:1a), b) of the:2009 edition];
c) Added identification requirements (see 5:2);
d) Added quality requirements (see 5:3);
e) Modified the software function (see 5:4, 5:2:3 of the:2009 edition);
f) Added self-test requirements (see 5:5, 5:2:4 of the:2009 edition);
g) revised storage capacity requirements [see 5:6, 5:2:3d) of the:2009 edition];
h) revised data interface requirements (see 5:7, 5:2:4 of the:2009 edition);
i) Modified the alarm prompt requirements (see 5:8, 5:2:5 of the:2009 edition);
j) Added school hours requirements (see 5:9);
k) delete the sampling method requirement (5:2:2 of the:2009 edition);
l) Modify the requirements for the types of detectable substances (see 5:11:2, 5:3:2 of the:2009 edition);
m) Modified the detection limit requirements (see 5:11:3, 5:3:4 of the:2009 edition);
n) Added self-cleaning time requirement (see 5:11:5);
o) Modify the overload recovery time requirements (see 5:11:6, 5:3:6 of the:2009 edition);
p) revised power requirements (see 5:12, 5:2:1 of the:2009 edition);
q) Modified the electrical safety requirements (see 5:13, 5:6:2 of the:2009 edition);
r) Modified radiation safety requirements (see 5:14, 5:6:1 and 5:5:2 of the:2009 edition);
s) Modified electromagnetic compatibility requirements (see 5:15, 5:5 of the:2009 edition);
t) Modified the requirements for environmental adaptability (see 5:16, 5:4 of the:2009 edition);
u) Modified the test environment requirements (see 6:1:1, 6:1 of the:2009 edition);
v) The configuration method of the detection solution was deleted (see 6:2:3 of the:2009 edition);
w) Revised the sample requirements for drugs and explosives (see 6:1:2, 6:2:1 of the:2009 edition); added the requirements for detector samples (see 6:1:3);
x) Modified the basic detection performance verification test method (see 6:2, 6:2:6 of the:2009 edition); test methods for the types of detectable substances
(See 6:13:4, 6:5:2 of the:2009 edition); Test methods for environmental suitability (see 6:18, 6:6 of the:2009 edition):
Please note that some content of this document may involve patents: The issuing agency of this document assumes no responsibility for identifying patents:
This document is proposed and managed by the National Standardization Technical Committee of Security Alarm System (SAC/TC100):
This document is drafted by: Safety and Police Electronic Product Quality Inspection Center of the Ministry of Public Security, the First Research Institute of the Ministry of Public Security, Beijing Shengxun Electronics Co:, Ltd:
Co:, Ltd:, Tongfang Weishi Technology Co:, Ltd:, Dalian Jinrui Weida Technology Co:, Ltd:, the Third Research Institute of the Ministry of Public Security, Beijing Institute of Technology:
The main drafters of this document: Qiu Rixiang, Li Wei, Teng Fei, Lu Yuhua, Guo Lizha, Bao Yuntian, Du Yongzhai, Liu Caixia, Li Bin, Jiang Qiong:
The previous versions of this document and its superseded documents are as follows:
--- GA/T 841-2009:
Trace quantities based on ion mobility spectrometry
General technical requirements for drug/explosive detectors
1 Scope
This document specifies the requirements for trace drug detectors, trace explosive detectors, trace drugs and explosive detectors based on ion mobility spectrometry:
Requirements for classification, technical requirements, marking, packaging, transportation and storage, describe test methods, and establish inspection rules:
This document applies to trace drug detectors, trace explosives detectors, trace drugs and explosives based on ion mobility spectrometry with swab sampling:
Design, manufacture and inspection of drug detectors:
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document:
GB/T 191 Graphical signs of packaging, storage and transportation
GB/T 2423:1-2008 Environmental Testing of Electrical and Electronic Products Part 2: Test Methods Test A: Low Temperature
GB/T 15211-2013 Environmental adaptability requirements and test methods for safety precaution and alarm equipment
GB 16796-2009 Safety requirements and test methods for safety precaution and alarm equipment
GB/T 17626:2-2018 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test
GB/T 17626:3-2016 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic field radiation immunity test
GB/T 17626:4-2018 Electromagnetic Compatibility Test and Measurement Technology Electrical Fast Transient Burst Immunity Test
GB/T 17626:5-2019 Electromagnetic Compatibility Test and Measurement Technology Surge (Shock) Immunity Test
3 Terms and Definitions
The following terms and definitions apply to this document:
3:1
ion mobility spectrometry
Using the difference in the mobility of gas-phase ions formed by the ionization reaction of substances in an electric field to achieve trace analysis for the identification of the tested sample
Technology:
3:2
wipe sampling wipesamplecolection
The method of wiping the surface of the test object with the sampling carrier to collect the sample for analysis:
3:3
Detection rate probabilityofdetection
The probability that the detector can correctly alarm when detecting explosives/drugs:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 841-2021_English be delivered?Answer: Upon your order, we will start to translate GA/T 841-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA/T 841-2021_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 841-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GA/T 841-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA/T 841-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|