|
US$229.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 208-2019: Forensic sciences--Examination methods for phosphide in biological samples--HSGC and HSGC-MS Status: Valid GA/T 208: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GA/T 208-2019 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Forensic sciences--Examination methods for phosphide in biological samples--HSGC and HSGC-MS
| Valid |
GA/T 208-2019
|
| GA/T 208-1999 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Methods of qualitative and quantitative analysis for phosphide in case samples
| Obsolete |
GA/T 208-1999
|
PDF similar to GA/T 208-2019
Basic data | Standard ID | GA/T 208-2019 (GA/T208-2019) | | Description (Translated English) | Forensic sciences--Examination methods for phosphide in biological samples--HSGC and HSGC-MS | | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | | Classification of Chinese Standard | A92 | | Classification of International Standard | 13.310 | | Word Count Estimation | 10,141 | | Date of Issue | 2019 | | Date of Implementation | 2019-12-01 | | Issuing agency(ies) | Ministry of Public Security |
GA/T 208-2019: Forensic sciences--Examination methods for phosphide in biological samples--HSGC and HSGC-MS ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forensic sciences--Examination methods for phosphide in biological samples--HSGC and HSGC-MS
ICS 13.310
A92
Public Safety Industry Standards of the People's Republic of China
Replace GA/T 208-1999
Inspection of phosphine in forensic biological samples
Headspace gas chromatography and headspace gas chromatography-mass spectrometry
Published on October 14,.2019
2019-12-01 Implementation
Issued by the Ministry of Public Security of the People's Republic of China
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GA/T 208-1999 "Qualitative and Quantitative Analysis Methods of Phosphide in Samples of Poisoning Cases", and GA/T 208-
Compared to.1999, the main technical changes except for editorial changes are as follows.
--- Modified the standard name (see cover, cover of.1999 edition);
--- Modified the relevant content of the scope (see Chapter 1, Chapter 1 of the.1999 edition);
---Revised the relevant content of normative reference documents (see Chapter 2, Chapter 2 of the.1999 edition);
--- Revised the first principle of headspace gas chromatography detection of phosphine and its metabolites (see Chapter 4,.1999 edition of the fourth
chapter);
--- Modified the first reagent for detecting phosphine and its metabolites by headspace gas chromatography (see Chapter 5,.1999 edition of No. 5)
chapter);
---Modified the first instrument and equipment for detecting phosphine and its metabolites by headspace gas chromatography (see Chapter 6,.1999 edition)
Chapter 6);
--- Modified the first qualitative and quantitative analysis of headspace gas chromatography for detection of phosphine and its metabolites (see Chapter 7,.1999)
Chapter 7 of the edition);
--- Deleted the second part of the AgDDC method for the determination of phosphine (see Chapter 8 ~ Chapter 11 of the.1999 edition);
--- Deleted the third content of mercury bromide test paper method for measuring phosphine (see Chapter 12 ~ Chapter 15 of the.1999 edition);
--- Modify the relevant content of Appendix A (see Appendix A, Appendix A of the.1999 edition);
--- Modify the relevant content of Appendix B (see Appendix B, Appendix B of the.1999 edition).
Please note that some content of this document may involve patents. The issuer of this document does not assume responsibility for identifying these patents.
This standard was proposed by the National Toxic Analysis Subcommittee of Criminal Technical Standardization Technical Committee (SAC/TC179/SC1) and
Be in charge.
This standard was drafted by. Physical Evidence Appraisal Center of the Ministry of Public Security, China Criminal Police College, Shaanxi Provincial Public Security Bureau, and Judicial Expertise Research Institute.
The main drafters of this standard. Hou Xiaoping, Chang Jing, Dong Ying, Du Hongyan, Cui Guanfeng, Zhu Yu, Zhang Aidong, Liu Wei.
Inspection of phosphine in forensic biological samples
Headspace gas chromatography and headspace gas chromatography-mass spectrometry
1 Scope
This standard specifies the headspace gas chromatography (HSGC) quantitative detection of phosphine in biological samples (blood, urine, liver, kidney, stomach and stomach contents, etc.)
Qualitative and quantitative inspection method of headspace gas chromatography-mass spectrometry (HSGC-MS).
This standard applies to qualitative and quantitative analysis of phosphine in biological samples. Qualitative analysis and determination of phosphine in other suspicious samples
Quantitative analysis can refer to use.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
GB/T 6682 Analysis laboratory water specifications and test methods
GA/T 122 Nomenclature of poison analysis
3 Terms and definitions
The terms and definitions defined in GA/T 122 apply to this document.
4 Principle
The blank sample and the added sample were used as controls. According to the requirements of parallel operation, headspace gas chromatography-mass spectrometry was used for quantification.
Chromatographic quantification, based on retention time, characteristic ion fragment peak of mass spectrometry and relative abundance ratio as qualitative judgment basis; based on peak area, use external
Standard method for quantitative analysis.
5 Reagents and materials
5.1 Reagent
The water used for the experiment shall conform to the third grade water specified in GB/T 6682.The reagents used in the analysis are of analytical grade, and the reagents include.
a) 20% sulfuric acid solution. take 20mL concentrated sulfuric acid and slowly add it to 80mL water;
b) Zinc powder (no arsenic);
c) Standard solution.
1) Sodium hypophosphite standard solution (equivalent to 1.0 mg/mL containing phosphine). accurately weigh sodium hypophosphite (NaH2PO2
H2O) Standard substance 155.90mg, dissolved in a small amount of water, diluted to 50mL, formulated to contain phosphine equivalent
The 1.0 mg/mL sodium hypophosphite standard solution was placed in the refrigerator and stored in a refrigerator. Valid for 1 month.
2) Sodium hypophosphite working solution (equivalent to 0.1mg/mL containing phosphine). Pipette sodium hypophosphite standard solution (equivalent to containing
Phosphine 1.0mg/mL), diluted with water to 10mL, sealed, placed in the refrigerator and stored in the refrigerator, valid for 7 days. experiment
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 208-2019_English be delivered?Answer: Upon your order, we will start to translate GA/T 208-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA/T 208-2019_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 208-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GA/T 208-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA/T 208-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|