US$249.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 1213-2014: Finger vein recognition applications in security systems. Technical requirements for 3D data
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GA/T 1213-2014 | English | 249 |
Add to Cart
|
3 days [Need to translate]
|
Finger vein recognition applications in security systems. Technical requirements for 3D data
| |
GA/T 1213-2014
|
PDF similar to GA/T 1213-2014
Basic data | Standard ID | GA/T 1213-2014 (GA/T1213-2014) | | Description (Translated English) | Finger vein recognition applications in security systems. Technical requirements for 3D data | | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | | Classification of Chinese Standard | A91 | | Classification of International Standard | 13.310 | | Word Count Estimation | 7,769 | | Date of Issue | 2014-12-22 | | Date of Implementation | 2015-01-01 | | Quoted Standard | GA/T 893; GA/T 940 | | Regulation (derived from) | Notice on Publication of Public Safety Industry Standard (Year of 2014); Industry Standard Record Announcement No. 4 of 2015 (No. 184) | | Issuing agency(ies) | Ministry of Public Security | | Summary | This standard specifies the effective area, coordinate system, and recording format for the application of 3D data in the finger vein recognition. This standard is applicable to the application of 3D data acquisition, storage, transmission and processing |
GA/T 1213-2014: Finger vein recognition applications in security systems. Technical requirements for 3D data ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Finger vein recognition applications in security systems.Technical requirements for 3D data
ICS 13.310
A91
People's Republic of China Public Security Industry Standards
Security finger vein recognition application
3D data Technical Requirements
Issued on. 2014-12-22
2015-01-01 implementation
People's Republic of China Ministry of Public Security
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The Standard Technical Committee biometric identification applications Technical Committee (SAC/by the National Security Alarm System Standardization
TC100/SC2) and focal points.
This standard was drafted. Electronic Science and Engineering, National University of Defense Science and Technology, Ministry of Public Security First Research Institute of Peking University.
The main drafters of this standard. Xie Jianbin, Hou Hongchuan, Li Wenxin, Liu Junping, Yan Wei, Liu Tong, Li Pei Qin.
Security finger vein recognition application
3D data Technical Requirements
1 Scope
This standard specifies the security refers to the effective area of vein recognition using 3D data, the coordinate system and the recording format.
This standard applies to the security finger vein recognition using 3D data acquisition, storage, transmission and processing.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GA/T 893 biometric security application terminology
GA/T 940 security finger vein image recognition application system technical requirements
3 Terms and Definitions
GA/T 893, GA/T 940 defined in the following terms and definitions apply to this document.
3.1
3D data 3Ddata
Description refers to the data of the spatial distribution of the vein.
4 the effective area of the coordinate system
4.1 effective area
The effective area should contain a complete knuckle area (area of the joint between two fingers), as shown in Figure 1a) in FIG.
4.2 Coordinate System
3D coordinate data by GA/T 940 is set, as shown in Figure 1b), in which. X, Y, Z direction left-handed coordinate system, X coordinate direction from
Refers to the root pointing fingers, Z coordinate direction from the fingertips pointing dorsal; XOY plane tangent to the pulp; rectangular region OABC-O'A'B'C 'contains
A complete knuckles. 3D data content stored only rectangular area OABC-O'A'B'C 'space coordinates vein sampling, as
Fig 1c).
4.3 effective area size
FIG. 1b) in, OA (L) is not less than 3cm, OC (width) is not less than 2cm, OO '(high) is not less than 2cm.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 1213-2014_English be delivered?Answer: Upon your order, we will start to translate GA/T 1213-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA/T 1213-2014_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 1213-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|