US$559.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 1031-2012: General technical requirements for leaky cable intrusion detecting devices
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GA/T 1031-2012 | English | 559 |
Add to Cart
|
4 days [Need to translate]
|
General technical requirements for leaky cable intrusion detecting devices
| |
GA/T 1031-2012
|
PDF similar to GA/T 1031-2012
Basic data Standard ID | GA/T 1031-2012 (GA/T1031-2012) | Description (Translated English) | General technical requirements for leaky cable intrusion detecting devices | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | Classification of Chinese Standard | A91 | Classification of International Standard | 13.310 | Word Count Estimation | 16,125 | Date of Issue | 2012-12-24 | Date of Implementation | 2013-03-01 | Quoted Standard | GB/T 2828.1-2003; GB 4208-2008; GB 10408.1-2000; GB 12663-2001; GB/T 15211-1994; GB 16796-2009; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17737.1-2000 | Regulation (derived from) | Announcement on Publication of Public Safety Industry Standard; Industry Standard Record Announcement No. 3 of 2013 (No. 159) | Issuing agency(ies) | Ministry of Public Security | Summary | This standard specifies the grading requirements, technical requirements, test methods, inspection rules, marking, packaging, storage and transportation requirements of leakage cable intrusion detection devices (referred to as devices). This standard appl |
GA/T 1031-2012: General technical requirements for leaky cable intrusion detecting devices---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General technical requirements for leaky cable intrusion detecting devices
ICS 13.310
A91
People's Republic of China Public Security Industry Standards
Leaky cable intrusion detection device common technical requirements
Issued on. 2012-12-24
2013-03-01 implementation
People's Republic of China Ministry of Public Security
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard by the National Security Alarm System Standardization Technical Committee (SAC/TC100) and focal points.
This standard was drafted. National Security Alarm System Product Quality Supervision and Inspection Center (Shanghai), national security alarm system production
Product Quality Supervision and Inspection Center (Beijing), Shanghai Shenda automatic systems engineering Co., Ltd., Shanghai, Hong shield Intelligent Technology Co., Ltd., Chengdu
Heidecke Science and Technology Development Co., Ltd. Haiou pulse Electronic Technology Development Co., Ltd., Shanghai Extension Information Technology Co., Ltd., Shanghai public security
Bureau of technical prevention office.
The main drafters of this standard. the Han Feng, Lushu Rong, Dong Pengfei, Songzu An, Jiang Qi, Huang Jin, Guo Shanyong A Rough Wu war, Wang Lei, Xie Feng,
Tao Yan L, Liu new, Wu Tianyi.
Leaky cable intrusion detection device common technical requirements
1 Scope
This standard specifies the leak cable intrusion detection device (the device) grading requirements, technical requirements, test methods, inspection rules, marking
Chi, packaging, storage and transportation requirements.
This standard applies to leaky cable intrusion detection device design, manufacture, installation, testing.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2828.1-2003 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch test sample
plan
GB 4208-2008 shell protection (IP code)
GB 10408.1-2000 intrusion detectors - Part 1. General requirements
GB 12663-2001 burglar alarm controller general technical conditions
GB/T 15211-1994 alarm system environmental testing
GB 16796-2009 security alarm equipment safety requirements and test methods for prevention
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test
GB/T 17737.1-2000 frequency cables - Part 1. Generic specification --- General, definitions, requirements and test methods
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Leaky cable leakycable
And receiving high-frequency electromagnetic radiation is used as energy for cable.
3.2
Leak detection cable host leakycabledetectingset
A reception, analysis/processing detection signal, and outputs a signal indicating intrusion alarm and other functions of the device.
3.3
Leaky cable intrusion detection device leakycableintrusiondetectingdevice
By a leaky cable, radiating cable and non-cable leak detector composed able to enter the area of intrusion detection alarm signal
equipment.
3.4
Detection area detectingarea
Perceive laying spill area around the cable high frequency electromagnetic field disturbance effectively.
|