HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GA 38-2021 English PDF

US$789.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GA 38-2021: Security requirements for banking business area
Status: Valid

GA 38: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 38-2021English789 Add to Cart 6 days [Need to translate] Security requirements for banking business area Valid GA 38-2021
GA 38-2015English599 Add to Cart 3 days [Need to translate] Security requirements for bank commercial premises Obsolete GA 38-2015
GA 38-2004English239 Add to Cart 3 days [Need to translate] Regulation on level of risk and classification of protection for banking business place Obsolete GA 38-2004
GA 38-1992English279 Add to Cart 3 days [Need to translate] (Bank business premises risk rating and protection level requirements) Obsolete GA 38-1992

PDF similar to GA 38-2021


Standard similar to GA 38-2021

GB 8108   GA 1051   GB 10408.3   GA/T 74   GA/T 73   GA/T 70   

Basic data

Standard ID GA 38-2021 (GA38-2021)
Description (Translated English) Security requirements for banking business area
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard A91
Word Count Estimation 34,394
Issuing agency(ies) Ministry of Public Security

GA 38-2021: Security requirements for banking business area

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Security requirements for banking business area ICS 13.310 CCSA91 Public Safety Industry Standards of the People's Republic of China Replace GA 38-2015, GA 745-2017, GA 858-2010 Partly replace GA 1003-2012, GA 1280-2015 Bank security requirements Released on 2021-03-24 2021-09-01 implementation Issued by the Ministry of Public Security of the People's Republic of China

Table of contents

Foreword Ⅲ Introduction Ⅵ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Key prevention sites and parts 4 5 General requirements 5 6 Security requirements for bank business premises 6 7 Bank self-service equipment, self-service banking security requirements 9 8 Security requirements for banking business libraries 12 9 Security requirements for safe deposit boxes 15 10 Security requirements for networked monitoring centers 16 11 Data center, data room, equipment room security requirements 16 Appendix A (Normative) Requirements for Bank Security Facilities Configuration 19 Appendix B (normative) Technical requirements for explosion-proof membrane 25 Appendix C (Normative) Requirements for the protection of other forms of cabinets in the cash zone and acceptance requirements for counters 26 Appendix D (Informative) Security Inspection Plan 27

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces GA 38-2015 "Security requirements for bank business premises", GA 745-2017 "Bank self-service equipment, self-service banking Security Requirements", GA 858-2010 "Security Requirements for Banking Business Databases", partially replacing GA 1003-2012 "Bank self-service Wuting Security Requirements", GA 1280-2015 "Automated Teller Machine Security Requirements", compared with the above documents, except for structural adjustments and editing In addition to the sexual changes, the main technical changes are as follows. 1) Added some terms (see 3.1, 3.3, 3.12.2, 3.12.3, 3.12.4, 3.13, 3.14, 3.16, 3.19, 3.20); 2) Some terms have been changed (see 3.12, 3.12.1, 3.21, 3.22, 3.2, 3.1 of GA 858-2010, 3.5, 3.11 of GA 38-2015); 3) Some terms have been deleted (see 3.8 and 3.12 of GA 38-2015 and 3.3 of GA 745-2017); 4) The construction principle is changed (see 5.1, 4.1.1 of GA 38-2015 and 5.1.1 of GA 858-2010); 5) Changed the site selection requirements (see 5.2, 5.1 of GA 745-2017 and 5.1.3 of GA 858-2010); 6) The data management requirements are changed (see 5.3, 5.1.2 of GA 858-2010); 7) Added pipeline protection requirements (see 5.5); 8) The equipment protection requirements are changed (see 5.6, 6.2.5 of GA 745-2017); 9) Added the time calibration requirements of the electronic protection system (see 5.9); 10) The main transmission channel for networked alarms has been added to give priority to the wired network, and when the main channel fails, it will automatically switch to the backup alarm channel. Requirements [see 5.12e)]; 11) The requirements for the storage time of business database intrusion and emergency alarm system information are changed [see 5.12g), GA 858-2010 5.3.2.9]; 12) Added the requirement that the anti-theft alarm controller should be installed in the protective area and have anti-vandalism alarm function [see 5.12h)]; 13) Deleted the requirement that the on-site sound and light alarm device can be activated when the alarm device is activated (see 4.3.2.7 of GA 38-2015); 14) Changed the permission management requirements for image browsing, playback and download [see 5.13f), GA 858-2010, 5.3.3.2]; 15) Deleted the requirement that cameras can be installed in other areas according to the site conditions [GA 38-2015 4.3.3.1f)]; 16) Changed the storage time requirements of the video image information of the business library [see 5.13h), GA 858-2010 5.3.3.11]; 17) Changed the storage time requirements for voice review intercom information in the business database (see 5.15, GA 858-2010, 5.3.5.3); 18) Added the safety requirements of the entrance and exit control system [see 5.14a)~c)]; 19) Add the requirements for the time deviation of video and audio synchronization (see 5.15); 20) Added requirements for explosion-proof security inspection system (see 5.16); 21) Added the requirement of not handling cash and other businesses manually in the non-cash area (see 6.1.3); 22) Deleted the requirement that a toilet should be installed in the cash area of the business place (see 4.1.5 of GA 38-2015); 23) The requirement for the outer wall of the business premises has been deleted (see 4.2.1.1 of GA 38-2015); 24) The requirements for the adjacent walls of the business premises and the outside world have been changed (see 6.2.1.1.1, 4.2.1.2 of GA 38-2015); 25) The height requirement of the glass curtain wall is changed (see 6.2.1.1.2, 4.2.1.2 of GA 38-2015); 26) Added the performance requirements of the explosion-proof membrane [see 6.2.1.1.2d), 6.2.2.2d) and Appendix B]; 27) Changed the wall requirements of the cash business area (see 6.2.1.2.2, 4.3.1.3.2 of GA 38-2015); 28) The requirements for rolling shutter doors are changed (see 6.2.2.1, 7.3.3b), 4.2.2.1, 4.4.1a) of GA 38-2015 and GA 745-2017 6.3b)]; 29) The strengthening requirements for windows below 5m in height difference between the bank's business premises and the outside ground, platform or aisle have been changed (see 6.2.2.2, 4.2.2.2 of GA 38-2015); 30) The length and installation requirements of steel plate structure counters have been changed [see 6.2.3.1b), GA 38-2015 4.2.3.1b)]; 31) Changed the performance requirements of the transparent protective plate [see 6.2.3.2a), GA 38-2015 4.2.3.2a)]; 32) The requirements for the protective steel plate of the cash register are changed [see 6.2.3.3c), 4.2.3.3c) of GA 38-2015]; 33) The overall protection performance requirements of the counter are changed (see 6.2.3.4, 4.2.3.4 of GA 38-2015); 34) Added the requirement that the anti-following linkage interlocking safety door channel does not have access to other areas (see 6.2.4); 35) Added the requirements for the installation of access control devices at the entrances and exits of the cash business area and the office area that communicate with the outside world (see 6.3.3) 36) Added the requirements for the installation of sound review devices in the connection channels of the customer activity area and the anti-following linkage interlocking safety door (see 6.3.4.2); 37) Deleted the requirement of installing sound review device in the cash adding area of self-service equipment (see 4.3.5.3 of GA 38-2015); 38) Deleted the remote teller system requirements (see 4.4.4 of GA 38-2015); 39) Added environmental illumination requirements for customer operating areas of bank self-service equipment (see 7.2.6); 40) Added the requirement that non-cash bank self-service equipment is not installed on the wall of the cash adding room (see 7.3.2.3); 41) The installation position and requirements of the upper and lower box intrusion detectors of cash bank self-service equipment have been changed (see 7.4.1.1, GA 745- 2017's 7.1.1); 42) Deleted the requirement that the self-service equipment add money area should install a sound review device (see 4.3.5.3 of GA 38-2015); 43) The location requirements of freight elevators and stairs in the business warehouse have been changed (see 8.2.2, 5.1.6 of GA 858-2010); 44) The requirements for the prevention and control isolation door are changed (see 8.2.4, 5.2.1.10 of GA 858-2010); 45) The physical protection requirements for the guard room and the clearing of the whole point have been added (see 8.2.5); 46) Added the requirement that any form of cash replenishment room, bank self-service equipment, cabinets, etc. cannot be used in place of the business library (see 8.2.6); 47) Added the protection requirements for the air supply and exhaust device of the banking warehouse (see 8.3.1.5); 48) The construction requirements of the four types of warehouses for business warehouses have been changed (see 8.3.4.1, 5.2.4.1 of GA 858-2010); 49) Added the requirements for the installation of prevention and control isolation doors in the four types of business warehouses in remote warehouses (see 8.3.4.3); 50) The requirements for installing vibration detectors on the walls of the warehouse and the inner walls of the corridor have been added (see 8.4.1.2); 51) Added the requirement of installing emergency alarm devices between the whole points of the sorting (see 8.4.1.3); 52) Added the requirement that two independent defense zones should be set up inside and outside the prevention and control isolation door of business libraries above three categories (see 8.4.1.4); 53) The requirements for the installation of entrance and exit control devices for the entrances and exits that communicate with the outside world and the prevention and control isolation doors in the business library have been added (see 8.4.3.1); 54) Added the requirement of installing a full-duplex mode voice intercom device on the prevention and control isolation door (see 8.4.4.1); 55) Added requirements for the installation of sound review devices in areas such as warehouses, guard rooms, clearing hour rooms, handover areas, loading and unloading areas, passages, and corridors (See 8.4.4.2); 56) The location requirements of the local guard room have been changed (see 8.5.1.1, 5.4.1 of GA 858-2010); 57) The requirements for walls, doors and windows of the local warehouse room have been changed (see 8.2.5, 8.5.1.2, 5.4.2, 5.4.3 of GA 858-2010); 58) Added the requirements for installing video surveillance devices inside and outside the local guardhouse (see 8.5.1.7); 59) The configuration requirements of the local guard room are changed (see 8.5.1.6, 5.4.6 of GA 858-2010); 60) Added the requirement for the local guard room to receive real-time alarm and other security information (see 8.5.1.8); 61) Added the operation requirements of the local guard room for arming and disarming the defense area outside the prevention and control isolation door (see 8.5.1.9); 62) Added the requirement of a special safe for guns and ammunition in the local depot (see 8.5.1.10); 63) Changed the requirements for remote storage (see 8.5.2, 5.3.6.1 of GA 858-2010); 64) Changed the requirements for dividing the whole point interval (see 8.5.3, 5.3.3.6 of GA 858-2010); 65) Added location requirements for handover area and loading area (see 8.5.4.1, 8.5.4.2); 66) The requirements for safe deposit box warehouses have been changed (see 9.1.2, 9.1.3, 4.4.2.5 and 4.4.2.6 of GA 38-2015); 67) The requirements for installing intrusion detectors in the warehouse have been changed (see 9.2.1, 4.4.2.3 of GA 38-2015); 68) Added the requirements for the installation of entrance and exit control devices at the entrance and exit of the safe deposit box (see 9.2.3); 69) Added security requirements for networked monitoring centers (see 10); 70) Added data center security requirements (see 11.1); 71) Added data room safety precaution requirements (see 11.2); 72) Added the requirements for the wall of the equipment room (see 11.3.1); 73) The requirements for the door between the equipment have been changed (see 11.3.2, 4.4.3.1 of GA 38-2015); 74) Added the requirements for equipment rooms set up in the cash business area (see 11.3.3); 75) The requirements for windows in the equipment room have been changed (see 11.3.4, 4.4.3.2 of GA 38-2015); 76) The requirement to install air conditioning or ventilation facilities in the equipment room has been deleted (see 4.4.3.4 of GA 38-2015). This document was submitted by the Public Security Administration of the Ministry of Public Security. This document is under the jurisdiction of the National Standardization Technical Committee for Security and Alarm System (SAC/TC100). This document was drafted by the Public Security Administration of the Ministry of Public Security, the Security and Police Electronic Product Quality Inspection Center of the Ministry of Public Security, the Beijing Municipal Public Security Bureau, Industrial and Commercial Bank of China Co., Ltd., Agricultural Bank of China Co., Ltd., Bank of China Co., Ltd., China Construction Bank Co., Ltd., China Post Group Co., Ltd., Hua Xia Bank Co., Ltd. Drafters of this document. Zhang Zuoliang, Yuan He, Qiu Rixiang, Liu Xu, Ren Ji, Ai Jinsong, Song Jinlei, Wang Jianli, Liu Cheng, Jiang Shenwei, Sun Fan, Gu Yan, Yang Huashu, Zhao Xiaobing, Zhao Wen.

Introduction

In accordance with the requirements of the national standardization reform, the Public Security Administration of the Ministry of Public Security organizes special Family’s requirements for GA 38-2015 "Security Requirements for Banking Places", GA 745-2017 "Security Requirements for Bank Self-service Equipment and Self-service Banking Requirements", GA 858-2010 "Security Requirements for Banking Business Databases", GA 1003-2012 "Security Requirements for Bank Self-Service Kiosks", GA 1280-2015 "Automated Teller Machine Security Requirements" and other standards are integrated, and the integrated standard replaces GA 38-2015, GA 745-2017, GA 858-2010, partially replace GA 1003-2012, GA 1280-2015, and become mandatory for the public safety industry The standard "Bank Security Requirements" is for bank business premises, self-service equipment, self-service banking, business libraries, safe deposit boxes, networked monitoring centers, and data centers. According to the construction, approval and acceptance, daily inspection, and safety assessment of key prevention sites and locations such as the center, data room, equipment room, etc. in accordance with. Bank security requirements

1 Scope

This document specifies the overall security requirements and business premises, self-service equipment, self-service banking, business warehouses, and custody of banking financial institutions. Safety precaution requirements for key precaution places and locations such as box warehouses, networked monitoring centers, data centers, data rooms, equipment rooms, etc. This document is applicable to the construction and management of the security protection system of banking financial institutions, and the related security of other financial institutions and security escort companies. The construction and management of the total prevention system can be implemented by reference.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to This document. GB/T 1499.2 Steel for reinforced concrete Part 2.Hot-rolled ribbed steel bars GB 10409 Anti-theft safe (box) GB 12899 General technical specifications for handheld metal detectors GB 15208.1 Micro-dose X-ray safety inspection equipment Part 1.General technical requirements GB 15210 General technical specification for pass-through metal detection doors GB/T 16676 Technical requirements for bank security, alarm and monitoring networking system GB 17565-2007 General technical requirements for anti-theft security doors GB/T 28181 Technical requirements for information transmission, exchange and control of public security and video surveillance networked systems GB/T 32581 Technical requirements for intrusion and emergency alarm system GB/T 37078-2018 Technical requirements for entrance and exit control system GB 37481-2019 General technical requirements for vault doors GB 50348 Security Engineering Technical Standard GA/T 73-2015 Mechanical anti-theft lock GA 165-2016 bulletproof transparent material GA/T 501 bank safe deposit box GA 576 Anti-tailing linkage interlocking safety door general technical requirements GA 667-2020 Explosion-proof transparent material GA/T 841 General technical requirements for trace narcotics/explosives detector based on ion mobility spectroscopy technology GA 844-2018 Anti-smashing transparent material GA 1051 special safe for guns and ammunition GA/T 1067 General technical requirements for liquid product safety inspection equipment based on Raman spectroscopy technology GA 1081 safety protection system maintenance specifications GA/T 1323 General technical requirements for trace explosive detector based on fluorescent polymer sensing technology GA/T 1337 Security requirements for protective cabins of bank self-service equipment GA/T 1343 Anti-riot Lifting Vehicle Blocking Barricade GA 1383 Alarm Operation Service Specification

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GA 38-2021_English be delivered?

Answer: Upon your order, we will start to translate GA 38-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GA 38-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GA 38-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GA 38-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA 38-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.