HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

FZ/T 10016-2020 English PDF

US$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
FZ/T 10016-2020: (Test method of polyacrylic acid starch for textile warp sizing. Determination of non-volatile content)
Status: Valid

FZ/T 10016: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
FZ/T 10016-2020English139 Add to Cart 3 days [Need to translate] (Test method of polyacrylic acid starch for textile warp sizing. Determination of non-volatile content) Valid FZ/T 10016-2020
FZ/T 10016-2011English239 Add to Cart 3 days [Need to translate] Testing method for polyacrylic sizes used in textile warp sizing. Determination of involatile substance content Obsolete FZ/T 10016-2011
FZ/T 10016-1999English199 Add to Cart 2 days [Need to translate] Sampling program of inspecting to production classification for grey yarn Obsolete FZ/T 10016-1999

PDF similar to FZ/T 10016-2020


Standard similar to FZ/T 10016-2020

GB/T 6097   FZ/T 01085   FZ/T 10007   FZ/T 10025   FZ/T 10026   FZ/T 10024   

Basic data

Standard ID FZ/T 10016-2020 (FZ/T10016-2020)
Description (Translated English) (Test method of polyacrylic acid starch for textile warp sizing. Determination of non-volatile content)
Sector / Industry Spinning & Textile Industry Standard (Recommended)
Classification of Chinese Standard W10
Word Count Estimation 6,687
Date of Issue 2020-12-09
Date of Implementation 2021-04-01
Older Standard (superseded by this standard) FZ/T 10016-2011
Regulation (derived from) Ministry of Industry and Information Technology Announcement No. 48 (2020)
Issuing agency(ies) Ministry of Industry and Information Technology of the People's Republic of China

FZ/T 10016-2020: (Test method of polyacrylic acid starch for textile warp sizing. Determination of non-volatile content)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Test method of polyacrylic acid starch for textile warp sizing.Determination of non-volatile content) ICS 59.080.01 W10 People's Republic of China Textile Industry Standard Replace FZ/T 10016-2011 Test method of polyacrylic acid sizing agent for textile warp sizing Determination of non-volatile content 2020-12-09 released Implementation on 2021-04-01 Issued by the Ministry of Industry and Information Technology of the People's Republic of China

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces FZ/T 10016-2011 "Test Method for Polyacrylic Sizing Size for Textile Sizing Non-volatile Content Determination". versus Compared with FZ/T 10016-2011, the main technical changes are as follows. ---The standard name is adjusted to "Test method for non-volatile content of polyacrylic acid sizing agent for textile warp sizing"; ---Adjusted the standard range; ---Added the contents of the operating procedures (see 5.2~5.6); ---Added the result display (see 6.2); ---Added Appendix A (informative appendix). This standard was proposed by the China National Textile and Apparel Council. This standard is under the jurisdiction of the Cotton Textile Branch of the National Textile Standardization Technical Committee (SAC/TC209/SC10). Drafting organizations of this standard. Shanghai Xinqili Auxiliary Technology Co., Ltd., Shanghai Textile Industry Technology Supervision Institute, Dajiali (Taicang) Quality Technical Testing Center Co., Ltd., Hubei Jiate New Material Co., Ltd., Kunshan Mingjia Auxiliary Co., Ltd., China Cotton Textile Industry Association. The main drafters of this standard. Lu Yanjing, Meng Hongcai, Zuo Shuwen, Yang Yinjun, Zhou Chongxu, Wang Shuochen, Xu Xiaoyuan. The previous versions of the standard replaced by this standard are as follows. ---FZ/T 10016-2011. Test method of polyacrylic acid sizing agent for textile warp sizing Determination of non-volatile content

1 Scope

This standard specifies the test method for determining the non-volatile content of polyacrylic acid sizing agent used for sizing textile warp yarns. This standard applies to polyacrylic acid sizing agents for textile warp sizing. Note. In the actual production of the enterprise, the rapid determination method can be carried out with reference to Appendix A, and the test results are only for production reference.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 8170 Numerical rounding rules and the expression and determination of limit values

3 Principle

Polyacrylic acid sizing sample for textile warp sizing, heat it at a specified temperature to remove volatiles until it is dried. After drying, the quality is dry. The percentage of the mass before drying indicates the non-volatile content.

4 Equipment and utensils

4.1 Balance. The weighing range is more than 100g, and the division value is 0.0001g. 4.2 Electric heating constant temperature oven. The test temperature is 105℃±2℃. 4.3 Glass dryer. 4.4 Weighing bottle. a flat weighing bottle with a cap of 50mm in diameter.

5 Operating procedures

5.1 Set the temperature of the electric thermostatic oven to 105°C, turn on the power supply, and make the temperature evenly rise to the set temperature (105°C ± 2°C). 5.2 Place the washed and dried weighing bottle (with lid) in an electric heating constant temperature oven to dry, constant weight (the weighing deviation after two dryings is ±0.0003g Within the range), take it out and put it in a desiccator to cool to room temperature. 5.3 Weigh the mass of the weighing bottle (with lid) to the nearest 0.0001g. 5.4 Weighing bottle (with lid) quickly weigh 3g ± 0.5g sample, accurate to 0.0001g, so that the sample is evenly spread on the bottom of the weighing bottle. 5.5 Place the weighing bottle (with lid) in the middle of an electric thermostatic oven with a constant temperature of 105℃±2℃, open the lid and place the lid against the weighing bottle Next, dry at 105℃±2℃, constant weight (weighing deviation after two dryings is within ±0.0003g range). 5.6 Cover the bottle cap, take out the weighing bottle, quickly put it in a desiccator and cool it to room temperature and then quickly weigh it (accurate to 0.0001g). 5.7 Repeat 5.4 to 5.6, and perform parallel tests on the same sample.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of FZ/T 10016-2020_English be delivered?

Answer: Upon your order, we will start to translate FZ/T 10016-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of FZ/T 10016-2020_English with my colleagues?

Answer: Yes. The purchased PDF of FZ/T 10016-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version FZ/T 10016-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version FZ/T 10016-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.