FZ/T 01008-2008

Chinese Standard: 'FZ/T 01008-2008'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
FZ/T 01008-2008English209 Add to Cart Days<=3 Coated fabrics. Determination of resistance to ageing by heat air Valid FZ/T 01008-2008
FZ/T 01008-2008Chinese14 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

   

BASIC DATA
Standard ID FZ/T 01008-2008 (FZ/T01008-2008)
Description (Translated English) Coated fabrics. Determination of resistance to ageing by heat air
Sector / Industry Spinning & Textile Industry Standard (Recommended)
Classification of Chinese Standard W04
Classification of International Standard 59.080.40
Word Count Estimation 8,831
Date of Issue 2008-04-23
Date of Implementation 2008-10-01
Older Standard (superseded by this standard) FZ/T 01008-1991
Quoted Standard GB 6529
Adopted Standard ISO 1419-1995, MOD
Drafting Organization Textile Standard (Beijing) Test and Certification Center Co., Ltd.
Administrative Organization National Standardization Technical Committee based textile branch
Regulation (derived from) NDRC Notice No. 28 of 2008
Proposing organization China Textile Industry Association
Issuing agency(ies) National Development and Reform Commission
Summary This standard specifies the measured through accelerated aging performance changes coated fabric four methods. This standard applies to all types of coated fabrics.

FZ/T 01008-2008
Coated fabrics.Determination of resistance to ageing by heat air
ICS 59.080.40
W04
People's Republic of China textile industry standards
Replacing FZ/T 01008-1991
Coated fabrics - Determination of hot air aging
(ISO 1419.1995, Rubber-orplastic-coatedfabrics-
Accelerated-ageingtests, MOD)
Posted 2008-04-23
2008-10-01 implementation
National Development and Reform Commission, People's Republic of China released
Foreword
This revised standard adopts ISO 1419.1995 "Rubber or plastic coated fabrics - Accelerated aging tests."
This standard is based on ISO 1419.1995 re-drafting, and ISO 1419.1995 is the main differences.
1. The standard name has been modified;
2. Increase the range of content for all types of coated fabric;
3. Remove the relevant provisions of the determination of mass per unit area of the coating;
4. Increase the formula (2);
5. Method B, Method C and Method D to increase the "aging time can be determined according to needs of buyers and sellers or agreement."
Instead of the standard FZ/T 01008-1991 "coated fabric hot air accelerated aging test method."
This standard FZ/T 01008-1991, made the following major technical revisions.
1. Method C and increases the method D, expanding the scope of application;
2. Increase the formula (2);
3. Remove the testing and production of time intervals;
4. Remove the steps of a method of measuring the value of A, C, to note the article;
5. Simplified Method B aging temperature is 70 ℃ a file.
The standard proposed by China Textile Industry Association.
This standard by the National Standardization Technical Committee based textile branch (SAC/TC209/SC1) centralized.
This standard was drafted. Textile Standard (Beijing) Inspection and Certification Center Co., Ltd., Hangzhou Paradise Umbrella Group Co., Ltd.
The main drafters of this standard. INDUSTRY AND Wang Qiwei.
This standard was first published in 1991, this revision is the first time.
Coated fabrics - Determination of hot air aging
1 Scope
This standard specifies four methods to measure changes in performance coated fabrics by accelerated aging.
This standard applies to all types of coated fabrics.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 6529 textiles conditioning and testing - Standard atmospheres
Heat loss of volatile substances 3 Method A --- P Vp C coated fabric
3.1 General
As a natural result of aging, PVC coated fabrics may be due to the loss of volatile matter and plasticity, which will adversely affect the performance of the coating,
To be affected will depend on the composition of the coating, it is necessary to assess the performance. By this method the sample is exposed to high temperature accelerated play
Hair loss was then measured mass loss of the coating.
3.2 Instrument
3.2.1 ventilated oven, there is a slow air circulation, ventilation was 3 times to 10 times per hour, and the adoption of appropriate controlled and measured air
Circulation. Should be equipped with a thermostat so that the sample is maintained at a desired temperature, if necessary, be equipped with exercise and humidity control apparatus, the sample is maintained at the desired
Relative humidity. It should also be in the right place with a temperature measuring device, if necessary, to be equipped with a humidity measuring device. Imported air
Before contact with the specimen should be kept at a predetermined temperature. Cope with the introduced air heating devices for electronic shielding, avoiding direct sample
Caused by radiation. In the oven aging should not be used indoors copper or copper alloy, the total volume of the sample did not exceed 10% of the effective volume of the oven. vertical
Sample spacing suspension of at least 10mm, the inner wall of the oven and sample distance of at least 50mm.
The oven temperature should be maintained at 100 ℃ ± 1 ℃.
3.2.2 thermometer, or other monitoring oven temperature of the display device.
3.2.3 scales, accurate to 0.001g.
3.3 Sample Preparation
At a distance of at least 50mm selvedge of the three samples at random clip from the sample, each sample size is 100cm2 ± 1cm2.
3.4 Determination of the humidity and quality
3.5 Program
Preheat the oven to the test temperature after 100 ℃ ± 1 ℃, will bring samples of wet and weighed into the oven, the sample without tension, and both sides
Exposed to hot air. Sample was removed from the oven after 16h.
3.6 Expression of results
According to formula (1) or (2) is calculated for each sample coating mass loss rate in percent (%), said.
Lmc =
C × 100%
(1)
Related standard:   FZ/T 01010-2012  FZ/T 01004-2008