US$179.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. DZ/T 0276.2-2015: Regulation for testing the physical and mechanical properties of rock. Part 2: Test for determining the water content of rock Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| DZ/T 0276.2-2015 | English | 179 |
Add to Cart
|
3 days [Need to translate]
|
Regulation for testing the physical and mechanical properties of rock. Part 2: Test for determining the water content of rock
| Valid |
DZ/T 0276.2-2015
|
PDF similar to DZ/T 0276.2-2015
Basic data | Standard ID | DZ/T 0276.2-2015 (DZ/T0276.2-2015) | | Description (Translated English) | Regulation for testing the physical and mechanical properties of rock. Part 2: Test for determining the water content of rock | | Sector / Industry | Geological Industry Standard (Recommended) | | Classification of Chinese Standard | D00 | | Classification of International Standard | 19.02 | | Word Count Estimation | 7,792 | | Date of Issue | 2015-02-04 | | Date of Implementation | 2015-04-01 | | Older Standard (superseded by this standard) | DY-94 | | Regulation (derived from) | Ministry of Land and Resources - Announcement 2015 No. 5 | | Issuing agency(ies) | Ministry of Land and Resources | | Summary | This Standard specifies the moisture content - Gravimetric rock. This Standard applies to test physical and mechanical properties of rock water content test. |
DZ/T 0276.2-2015: Regulation for testing the physical and mechanical properties of rock. Part 2: Test for determining the water content of rock ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Regulation for testing the physical and mechanical properties of rock.Part 2. Test for determining the water content of rock
ICS 19.020
D00
People's Republic of China geological mineral industry standard
Instead of DY-94
Rock physics and mechanics properties test procedures
Part 2. Rock moisture test
Part 2.Testfordeterminingthewatercontentofrock
Released on.2015-02-04
2015-04-01 implementation
Ministry of Land and Resources of the People's Republic of China
Foreword
DZ/T 0276 "Testing Procedures for Physical and Mechanical Properties of Rocks" is divided into 31 parts.
--- Part 1. General and general provisions;
--- Part 2. Rock moisture test;
--- Part 3. Rock particle density test;
--- Part 4. Rock density test;
---Part 5. Rock water absorption test;
---Part 6. Rock hardness test;
--- Part 7. Rock gloss test;
--- Part 8. Rock antifreeze test;
---Part 9. Rock resistance to disintegration test;
--- Part 10. Rock expansion test;
--- Part 11. Rock erosion test;
--- Part 12. Rock acid and alkali resistance test;
--- Part 13. Rock specific heat test;
--- Part 14. Rock thermal conductivity test;
---Part 15. Rock breakdown voltage and breakdown strength test;
---Part 16. Rock volume resistivity and surface resistivity test;
--- Part 17. Rock radioactivity specific activity test;
---Part 18. Rock uniaxial compressive strength test;
---Part 19. Rock uniaxial compression deformation test;
--- Part 20. Rock triaxial compression strength test;
--- Part 21. Rock tensile strength test;
--- Part 22. Rock flexural strength test;
--- Part 23. Rock point load strength test;
--- Part 24. Rock acoustic wave velocity test;
---Part 25. Rock shear strength test;
--- Part 26. Rock mass deformation test (bearing plate method);
--- Part 27. Rock mass deformation test (drilling deformation method);
---Part 28. Rock mass strength test (direct shear test);
--- Part 29. Rock mass strength test (bearing plate method);
--- Part 30. Rock mass bolt load test;
--- Part 31. Rock sound wave velocity test.
This part is the second part of DZ/T 0276.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces DY-94 "Testing procedures for physical and mechanical properties of rock 2. Moisture test". This part is compared with DY-94, the main technology
The changes are as follows.
--- Added two chapters "terms and definitions" and "principles";
--- Modified the sample quantity requirements;
--- Modified the drying time of the sample at 105 ° C ~ 110 ° C temperature;
--- Modified the rock moisture test record table.
This part is proposed by the Ministry of Land and Resources of the People's Republic of China.
This part is under the jurisdiction of the National Land Resources Standardization Technical Committee (SAC/TC93).
This part was drafted by the Hubei Institute of Geological Experiments, and the Guangdong Geological Experimental Testing Center participated in the drafting.
The main drafters of this section. Yao Qianyuan, He Feng, Liu Wenhua.
The previous versions of the standards replaced by this section are.
---DY-86;
---DY-94.
Rock physics and mechanics properties test procedures
Part 2. Rock moisture test
1 Scope
This part of DZ/T 0276 specifies the gravimetric method for determining rock moisture content.
This section applies to rock moisture test in rock physical and mechanical properties test.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1
Water content watercontent
The ratio of the mass of moisture lost to the quality of the dried sample when the sample is dried under specified temperature conditions is expressed as a mass fraction.
3 Principle
The sample is dried to a constant weight at a predetermined temperature, and the mass of the sample before and after drying is weighed to calculate the water content.
4 instruments
4.1 Balance. The maximum weighing value is 1000g, and the reading accuracy is 0.01g.
4.2 Drying box.
4.3 Dryer.
5 sample
Each group of samples is not less than 5 pieces, the mass of the single piece of sample is greater than 150g, and the volume is greater than 60,000mm3.
6 test steps
6.1 Prepare the sample and weigh it. For loose rock that is not easy to form, it should be tested with a sample box with a sealed lid.
6.2 Place the sample in a dry box and bake for 12 hours.
a) For rocks without crystal water, the drying temperature ranges from 105 °C to 110 °C.
b) For rocks containing crystal water, such as gypsum, salt rock, montmorillonite, vermiculite, etc., the drying temperature ranges from 60 °C ± 5 °C.
6.3 Remove the sample from the drying oven, place it in a desiccator and cool to room temperature, and weigh the sample. The above steps are repeated every 2 hours, straight
Until the adjacent two weighing errors are less than 0.1%.
6.4 The contents and format of the test process are shown in Appendix A.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of DZ/T 0276.2-2015_English be delivered?Answer: Upon your order, we will start to translate DZ/T 0276.2-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of DZ/T 0276.2-2015_English with my colleagues?Answer: Yes. The purchased PDF of DZ/T 0276.2-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|