US$709.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. CJ/T 352-2010: Variable-frequency governed speed water supply equipment with microcomputer control Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
CJ/T 352-2010 | English | 709 |
Add to Cart
|
5 days [Need to translate]
|
Variable-frequency governed speed water supply equipment with microcomputer control
| Valid |
CJ/T 352-2010
|
PDF similar to CJ/T 352-2010
Basic data Standard ID | CJ/T 352-2010 (CJ/T352-2010) | Description (Translated English) | Variable-frequency governed speed water supply equipment with microcomputer control | Sector / Industry | Urban Construction Industry Standard (Recommended) | Classification of Chinese Standard | Q81 | Classification of International Standard | 91.140.60 | Word Count Estimation | 27,261 | Date of Issue | 2010-10-21 | Date of Implementation | 2011-05-01 | Older Standard (superseded by this standard) | JG/T 3009-1993 | Quoted Standard | GB 150; GB/T 156; GB/T 191; GB 755; GB/T 985.1; GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.3-2006; GB/T 2816; GB/T 3047.1; GB/T 3091; GB/T 3797-2005; GB 4208; GB/T 5657; GB/T 8163; GB/T 9119; GB/T 9123.1; GB/T 9969; GB/T 12238; GB/T 12459; GB/T 12668.2; GB/T 12771; GB/T 13384; GB/T 14549; GB/T 14976; GB/T 17219; GB/T 17626.7; GB 50236; GB 50268; GB 50343; CJ/T 156; CJ/T 167; CJ/T 208; JB/T 8097-1999; JB/T 8098-1999; JB/T 8937 | Regulation (derived from) | Ministry of Housing and Urban Notice No. 783 | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | Summary | This standard specifies the relay protection devices in the technology management, inspection management, operation management and the division of responsibilities and other requirements. This standard applies to 10kV and above the main electrical power system equipment and lines of relay protection devices. |
CJ/T 352-2010: Variable-frequency governed speed water supply equipment with microcomputer control ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Variable-frequency governed speed water supply equipment with microcomputer control
People's Republic of China urban construction industry standards
Instead of JG/T 3009-1993
Computer control frequency conversion water supply equipment
Posted on.2010-10-21
2011-05-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 categories and models 3
5 working conditions 3
6 Requirements 4
7 Test Methods 9
8 Inspection rules 15
9 logo, packaging, transportation and storage 17
Appendix A (Normative) Frequency Converter Requirements 19
Appendix B (informative) wire marking, light and button color 21
Appendix C (informative) test instrument used 22
Appendix D (informative) equipment test equipment 23
Foreword
This standard is JG/T 3009-1993 "computer-controlled variable frequency speed control water supply equipment" amendment.
This standard and JG/T 3009-1993 compared to the main technical changes are as follows.
--- In the scope of the provisions of the revised theme, an increase of the pressure applied to the boundaries of work and water temperature, pointed out that does not apply
limit;
--- Increased computer-controlled variable frequency speed control water supply equipment, rated water flow, equipment head, pressure control error, overpressure protection term
And defines and modifies the expression of the terms, points out the composition of microcomputer-controlled frequency conversion speed regulating water supply equipment;
--- In the classification of the provisions of the deleted by the control mode, structure, control the number of pumps the classification, an increase of medium temperature plan
Points, and added the model's markings and examples;
--- The "working conditions" as an external separate column, and increased the vertical installation of tilt, power supply voltage, power frequency, power supply
Power requirements
--- Increased the structure and layout, appearance quality, water pump, equipment configuration, the basic material requirements, modify the health performance requirements
(See 6.1);
--- Increased water supply capacity, low-flow operation, manual, automatic and remote control, overpressure protection, automatic pump switch
Function, standby pump since the cast function, noise and vibration performance requirements, modify the water level control, pressure control, automatic insurance
Protection function, compressive strength, anti-interference, anti-harmonic pollution requirements, an increase of remote monitoring, monitoring, monitoring functions, man-machine
Optional features for the port function, end water level communication interface functions, deletion of low temperature storage test, high temperature storage test, transport
Test requirements (see 6.2);
--- In the control cabinet requirements, the control cabinet shell modified level and the control cabinet wire, light and button color to be
Seeking, increase the requirements of lightning protection, drop test (see 6.3 and Appendix B);
--- Increased the selection of pump units, as well as the suction pipe, the configuration of the outlet pipe, the tube flow rate requirements (see 6.4);
--- Increased the use of pipes, fittings, valves, gauges, pressure tank requirements, and increased processing, welding requirements (see 6.5 and
6.6);
--- Increased the provisions of the test instruments used, modified equipment test equipment, modify or increase the requirements of the corresponding test methods (see
Chapter 7 and Appendix C, Appendix D);
--- Modify the logo, packaging, transport requirements (see 9.1, 9.2 and 9.3);
--- Increasing the requirements of the inverter (see Appendix A).
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Water Supply and Drainage Products Standardization Technical Committee.
This standard was drafted. Qingdao Sanli Group Co., Ltd., China Institute of Architectural Design.
The main drafters of this standard. Cui Jihong, Zhao Li, Wang Xuecheng, Xia Weiguang, Wang Zhanming, Hou Fenglin.
This standard replaces the standards previously issued as follows.
--- JG/T 3009-1993.
Computer control frequency conversion water supply equipment
1 Scope
This standard specifies the terms and definitions computer controlled variable frequency water supply equipment, classification and model, working conditions, requirements, test methods,
Inspection rules, marking, packaging, transportation and storage.
This standard applies to the working pressure is not greater than 2.5MPa, the water temperature is not greater than 80 ℃ of life, the production of water supply system with computer-controlled variable frequency
Speed water supply equipment.
This standard does not apply to the use of variable frequency motor or pump integrated inverter and fire water supply equipment.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 150 steel pressure vessel
GB/T 156 standard voltage
GB/T 191 Packaging - Pictorial signs
GB 755 Rotating motor quotas and performance (IEC 60034-1..2004, IDT)
GB/T 985.1 gas welding, welding arc welding, gas shielded welding and high-beam welding recommended groove
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (IEC 60068-2-
1..2007, IDT)
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature (IEC 60068-2-
2..2007, IDT)
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods Test Cab. constant hot and humid test
(IEC 60068-2-78..2001, IDT)
GB/T 2816 wells with submersible pumps
GB/T 3047.1 height of 20mm panel, frame and cabinet basic dimensions
GB/T 3091 low pressure fluid delivery welded steel pipe
Electrical control equipment GB/T 3797-2005
GB 4208 Enclosure Rating (IP Code) (IEC 60529..2001, IDT)
GB/T 5657 centrifugal pump technical conditions (Class Ⅲ)
GB/T 8163 seamless steel pipe for conveying fluid
GB/T 9119 flat, convex plate flat welded steel pipe flange
GB/T 9123.1 flat, convex steel pipe flange cover
GB/T 9969 Industrial Products Manual General
GB/T 12238 flange and the clamp connection flexible sealing butterfly valve
GB/T 12459 butt welded steel seamless fittings
GB/T 12668.2 speed control electrical transmission system Part 2. General Requirements Low-voltage AC variable frequency electrical drive system rating
Regulations (IEC 61800-2..1998, IDT)
GB/T 12771 stainless steel welded steel pipe for fluid transport
GB/T 13384 mechanical and electrical product packaging General technical conditions
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of CJ/T 352-2010_English be delivered?Answer: Upon your order, we will start to translate CJ/T 352-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of CJ/T 352-2010_English with my colleagues?Answer: Yes. The purchased PDF of CJ/T 352-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|