US$1109.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. CJ/T 30-2013: Thermocouple electromagnetic protector of extinguishment for gas appliance Status: Valid CJ/T 30: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| CJ/T 30-2013 | English | 1109 |
Add to Cart
|
7 days [Need to translate]
|
Thermocouple electromagnetic protector of extinguishment for gas appliance
| Valid |
CJ/T 30-2013
|
| CJ 30-1999 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
Thermocouple electromagnetic protector of extinguishment for gas appliance
| Obsolete |
CJ 30-1999
|
| CJ/T 30-1991 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
(Urban passenger vehicle repair general technical conditions)
| Obsolete |
CJ/T 30-1991
|
PDF similar to CJ/T 30-2013
Basic data | Standard ID | CJ/T 30-2013 (CJ/T30-2013) | | Description (Translated English) | Thermocouple electromagnetic protector of extinguishment for gas appliance | | Sector / Industry | Urban Construction Industry Standard (Recommended) | | Classification of Chinese Standard | P45 | | Classification of International Standard | 91.140 | | Word Count Estimation | 45,498 | | Older Standard (superseded by this standard) | CJ 30-1999 | | Quoted Standard | GB/T 191; GB/T 1019-2008; GB/T 3091; GB 4706.1; GB 4706.94; GB/T 4857.3; GB/T 4857.5; GB/T 7307; GB/T 9144; GB/T 12716; GB/T 13611; GB 14536.1-2008; GB/T 15092.1; GB/T 16411-2008; CJ/T 222-2006; GB/T 7306.1; GB/T 7306.2 | | Adopted Standard | BS EN 125-2010; MOD | | Regulation (derived from) | Department of Housing and Urban-Rural Development Bulletin No. 18; industry standard filing Notice 2013 No. 7 (No. 163 overall) | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | | Summary | This standard specifies: thermoelectric Appliance flameout protection device terms and definitions, classification, structure and materials, requirements, test methods, inspection rules, marking, installation and operating instructions, packaging, transpo |
CJ/T 30-2013: Thermocouple electromagnetic protector of extinguishment for gas appliance---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Thermocouple electromagnetic protector of extinguishment for gas appliance
ICS 91.140
P45
People's Republic of China urban construction industry standards
Replacing CJ 30-1999
Thermoelectric burner flameout protection device
2013-04-27 released
2013-10-01 Implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 Categories 2
4.1 Flameout protection device classification 2
4.2 flameout protection device grouping 3
5 Structure and materials 3
5.1 Structure 3
5.2 Materials 5
5.3 gas connection 6
6 Requirements 8
6.1 General Requirements 8
6.2 Air tightness 8
6.3 Torsion and bending 9
6.4 rated flow 9
6.5 Durability 9
6.6 Functional Requirements 10
6.7 Durability 11
7 Test Method 12
7.1 Test conditions 12
7.2 Air tightness test 12
7.3 Torsion and Bending Tests 13
7.4 rated flow test 15
7.5 Durability test 16
7.6 Functional test 17
7.7 Durability test 20
8 Inspection Rules 21
8.1 General requirements 21
8.2 unqualified classification 21
9 Identification, installation and operating instructions 22
9.1 logo 22
9.2 Installation and Operating Instructions 22
9.3 Warnings 23
10 Packaging, transportation and storage 23
10.1 General requirements 23
10.2 Packaging 23
10.3 Transportation 24
10.4 Storage 24
Appendix A (informative) This standard and BSEN125..2010 compared to the structural changes 25
Appendix B (informative) This standard and BSEN125..2010 technical differences and their causes 28
Appendix C (informative) flameout protection device type and composition 30
Appendix D (informative) flame sensing thermocouple installation requirements 32
Appendix E (Normative) Flame-retardant protective devices using auxiliary energy special requirements 33
Appendix F (Informative) Solenoid single test method 34
Appendix G (Informative) Air tightness test --- volume method 36
Appendix H (informative) This standard supports the provisions of the basic requirements of GB 16914-2012 corresponding table 38
References 40
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces CJ 30-1999 "thermoelectric burner flameout protection device", compared with the CJ 30-1999, the main technical changes are as follows.
--- Increased use of auxiliary energy thermoelectric burner flameout protection device (see Chapter 1, Appendix E);
--- Increased torsion and bending, rated flow, operating characteristics and air tightness requirements (see 6.3,6.4,6.6.1,6.6.5);
--- Modify the thermoelectric gas flameout protection device classification (see Chapter 4,.1999 edition of Chapter 4);
--- Modify the valve opening time, valve closing time requirements (see 6.6.4,.1999 version 5.2.3);
--- Deleted the establishment of models (see.1999 version 4.4);
--- Removed the open valve current requirements (1999 version 5.2.2).
This standard uses redrafted Law Amendment adopts BSEN125..2010 "gas appliance flame control device thermoelectric flame monitoring device."
This standard and BSEN125..2010 compared to more structural adjustment, Appendix A lists the standard and BSEN125..2010 chapter
Article number control list.
This standard compared with BSEN125..2010 there are technical differences, the provisions of these differences have been passed in the outer margin of the page margin
Set the vertical single line (︱) marked, Appendix B shows the corresponding technical differences and their causes list.
This standard is consistent with GB 16914-2012 "gas burning appliances safety conditions," Appendix H gives the standard branch
GB 16914-2012 with the basic requirements of the provisions of the corresponding table.
This standard made the following editorial changes.
--- Modify the standard name as "thermoelectric burner flameout protection device";
--- Removed BSEN125..2010 cover, directory, preface and description;
--- Removed BSEN125..2010 Appendix A (informative) "countries commonly used gas connection";
--- Removed BSEN125..2010 Annex C (informative) "Gas tightness test --- pressure loss method";
--- Removed BSEN125..2010 Appendix D (normative) "pressure loss method converted into leakage";
--- Removed the BSEN125..2010 Appendix F (normative) "EU quality 97/23/EC in the safety Annex and pressure
Additional requirements for attachments ";
--- Removed BSEN125..2010 Appendix G (normative) "pressure parts material";
--- Removed BSEN125..2010 Appendix H (informative) "compression parts additional materials";
--- Removed BSEN125..2010 Appendix ZA (Informative) "on gas fuels EU standards and EC directives
2009/142/EC correspondence between;
--- Added Appendix C (informative) "flameout protection device type and composition";
--- Added Appendix D (informative) "flame sensing thermocouple installation requirements";
--- Added Appendix E (normative) "use auxiliary energy flameout protection device special requirements";
--- Added Appendix F (informative) "Solenoid single test method."
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Gas Standardization Technical Committee centralized.
This standard was drafted. Zhejiang Siguo Precision Electrical Co., Ltd., Austrian can Electronics (Kunshan) Co., Ltd., the quality of national gas appliances
Inspection Center, Ningbo Wanbao Electric Co., Ltd., Ningbo Okay Security Technology Co., Ltd., Zhongshan Chun Ye Jia Ante Appliance Co., Ltd.
North China Municipal Engineering Design and Research Institute.
The main drafters of this standard. Han Songhe, Li Wenqing, Pan Cuijing, Sun Weibao, Jiang Chunfei, Zong Wei, drainage Yanhong, Shen Haixia.
This standard replaces the standards previously issued as follows.
--- CJ 30-1999.
Thermoelectric burner flameout protection device
1 Scope
This standard specifies the terms and definitions, classification, structure and material of the thermoelectric burner flameout protection device (hereinafter referred to as "flameout protection device")
Materials, requirements, test methods, inspection rules, marking, installation and operating instructions, packaging, transportation and storage.
This standard applies to indicate the maximum working pressure below 10kPa, the nominal connection size is not greater than DN50, and used in line with
GB/T 13611 provisions of urban gas appliances with thermoelectric burner flameout protection device.
This standard also applies to.
--- By the thermoelectric power-driven, can be individually tested for the thermoelectric ignition flameout protection device solenoid valve;
--- flame sensing thermocouple;
--- The use of auxiliary energy thermoelectric burner flameout protection devices (such as externally supplied electricity).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780..1997, MOD)
GB/T 1019-2008 Household and similar electrical appliances packaging General
GB/T 3091 welded steel pipe for delivery of low-pressure fluid (GB/T 3091-2008, ISO 559..1991, NEQ)
GB 4706.1 Household and similar electrical appliances - Safety Part 1. General requirements (GB 4706.1-2005, IEC 60335-1.
2004 (Ed4.1), IDT)
GB 4706.94 Safety of household and similar electrical appliances Electrical connections to the use of gas, fuel and solid fuel appliances Special
Special requirements (GB 4706.94-2008, IEC 60335-2-102..2004, IDT)
GB/T 4857.3 Packaging - Transport packages - Basic test - Part 3. Static load stacking test method (GB/T 4857.3-2008,
ISO 2234..2000, IDT)
GB/T 4857.5 package transport package drop test method (GB/T 4857.5-1992, eqvISO 2248. 1985)
GB/T 7306 (all parts) 55 ° sealing pipe thread
GB/T 7307 55 ° non-sealed pipe thread (GB/T 7307-2001, eqvISO 228-1..1994)
GB/T 9144 ordinary thread preferred series (GB/T 9144-2003, ISO 262..1998, MOD)
GB/T 12716 60 ° sealing pipe thread
GB/T 13611 urban gas classification and basic characteristics
GB 14536.1-2008 Household and similar electrical automatic controllers - Part 1. General requirements (IEC 60730-1..2003
(Ed3.1), IDT)
GB/T 15092.1 appliance switches - Part 1. General requirements (GB 15092.1-2010, IEC 61058-1..2008 (Ed.3.2),
IDT)
Household gas appliances GB/T 16411-2008 General test methods
Domestic gas burning appliances conformity assessment procedures and acceptance rules
|