HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

CJ/T 141-2018 English PDF

CJ/T 141: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
CJ/T 141-2018EnglishRFQ ASK 3 days [Need to translate] Standard of water quality examination methods for urban water supply Valid CJ/T 141-2018
CJ/T 141-2001English359 Add to Cart 3 days [Need to translate] Urban water supply. Determination of silica dioxide. Molybdosilicate blue method Obsolete CJ/T 141-2001

PDF similar to CJ/T 141-2018


Standard similar to CJ/T 141-2018

GB/T 5750.1   GB 5749   GB/T 5750.10   CJJ/T 125   CJ/T 106   CJJ/T 141   

Basic data

Standard ID CJ/T 141-2018 (CJ/T141-2018)
Description (Translated English) Standard of water quality examination methods for urban water supply
Sector / Industry Urban Construction Industry Standard (Recommended)
Classification of Chinese Standard C51
Classification of International Standard 13.060.20
Word Count Estimation 151,165
Date of Issue 2018-06-12
Date of Implementation 2018-12-01
Older Standard (superseded by this standard) CJ/T 150-2001; CJ/T 149-2001; CJ/T 148-2001; CJ/T 147-2001; CJ/T 146-2001; CJ/T 145-2001; CJ/T 144-2001; CJ/T 143-2001; CJ/T 142-2001; CJ/T 141-2001
Quoted Standard GB/T 5750.1; GB/T 5750.2; GB/T 5750.3; GB/T 5750.4; GB/T 5750.5; GB/T 5750.6; GB/T 5750.7; GB/T 5750.8; GB/T 5750.9; GB/T 5750.10; GB/T 5750.11; GB/T 5750.12; GB/T 5750.13; GB/T 6682; GB 15603; GB 19489; GB/T 27476.1; GB/T 27476.5
Regulation (derived from) Ministry of Housing and Urban-Rural Development Announcement No. 118 of 2018
Issuing agency(ies) Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary This standard specifies the terms and definitions, general rules, inorganic and sensory traits indicators, organic matter indicators, pesticide indicators, odorant substances indicators, disinfectant and disinfection by-product indicators, microbiological indicators and comprehensive indicators of urban water supply testing methods. This standard applies to the water quality testing of urban water supply and its source water.

CJ/T 141-2018: Standard of water quality examination methods for urban water supply

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard of water quality examination methods for urban water supply ICS 13.060.20 C51 People's Republic of China urban construction industry standards Replace CJ/T 141~CJ/T 150-2001 Town water supply quality standard test method Published on.2018-06-12 2018-12-01 implementation Ministry of Housing and Urban-Rural Development

Content

Foreword V 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 3.1 Minimum detection mass concentration 1 3.2 Precision 1 3.3 Accuracy 1 4 General 1 4.1 Selection of test methods 1 4.2 Reagents and concentration representation 2 4.3 Experimental pure water 2 4.4 Metrology verification/calibration and maintenance of testing instruments 2 4.5 Laboratory Safety 2 4.6 Quality Control and Assurance 2 5 Inorganic and sensory traits indicators 2 5.1 stinky 2 5.2 Cyanide 6 5.3 Sulfide 12 5.4 Volatile Phenol 18 5.5 Anionic synthetic detergent 24 5.6 Silica 29 6 Organic indicators 31 6.1 Vinyl chloride 31 6.2 1,1,1-trichloroethane 37 6.3 1,1,2-trichloroethane 37 6.4 Carbon tetrachloride 37 6.5 1,2-dichloroethane 37 6.6 1,1-dichloroethylene 37 6.7 1,2-dichloroethylene 37 6.8 Trichloroethylene 37 6.9 Tetrachloroethylene 37 6.10 Hexachlorobutadiene 37 6.11 Benzene 38 6.12 Toluene 45 6.13 xylene 45 6.14 ethylbenzene 45 6.15 styrene 46 6.16 Chlorobenzene 46 6.17 1,2-dichlorobenzene 50 6.18 1,4-dichlorobenzene 57 6.19 Trichlorobenzene 57 6.20 Hexachlorobenzene 57 6.21 Epichlorohydrin 57 6.22 Acrylamide 60 6.23 Microcystins - LR 63 6.24 Microcystins - RR 67 6.25 Phenol 67 6.26 4-nitrophenol 72 6.27 3-methylphenol 72 6.28 2,4-dichlorophenol 72 6.29 naphthalene 73 6.30 fluoranthene 77 6.31 Benzo(b)fluoranthene 77 6.32 Benzo(k)fluoranthene 77 6.33 Benzo(a)芘77 6.34 benzo (ghi) 苝 77 6.35 茚[1,2,3-c,d]芘77 7 Pesticide indicator 77 7.1 Dichlorvos 77 7.2 Lego 89 7.3 Parathion 89 7.4 methyl parathion 90 7.5 2,4-drop 90 7.6 heptachlor 90 7.7 chlorpyrifos 92 7.8 chlorpyrifos 95 7.9 Malathion 98 7.10 Atrazine 98 7.11 Carbofuran 98 7.12 deltamethrin 98 7.13 Pentachlorophenol 98 7.14 Glyphosate 98 7.15 Trichlorfon 103 8 Odorogenic indicators 103 8.1 Geosmin 103 8.2 2-Methylisodecyl alcohol 107 9 Disinfectants and disinfection by-product indicators 107 9.1 Ozone 107 9.2 Chlorine dioxide 109 9.3 chloroform 111 9.4 Tribromomethane 111 9.5 monobromodichloromethane 111 9.6 dibromochloromethane 111 9.7 dichloromethane 111 9.8 Dichloroacetic acid 112 9.9 Trichloroacetic acid 121 9.10 monochloroacetic acid 121 9.11 monobromoacetic acid 121 9.12 monochloro-bromoacetic acid 121 9.13 dibromoacetic acid 121 9.14 monobromodichloroacetic acid 121 9.15 monochlorodibromoacetate 121 9.16 tribromoacetic acid 121 9.17 2,4,6-trichlorophenol 121 10 Microbial indicators 121 10.1 Giardia 123 10.2 Cryptosporidium 131 10.3 Streptococcus faecalis 131 10.4 Sulfite reduction anaerobic bacteria (C. coli) spores 136 11 Comprehensive indicator 141 11.1 Mutagenicity of urban water supply 141

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces CJ/T 141~CJ/T 150-2001 "Standards for Water Quality Inspection Methods for Urban Water Supply". With CJ/T 141~CJ/T 150- Compared with.2001, the main technical changes are as follows. --- Increased odor, cyanide, sulfide, volatile phenol, anionic synthetic detergent, vinyl chloride, 1,1,1-trichloroethane, 1,1,2-trichloro Ethane, carbon tetrachloride, 1,2-dichloroethane, 1,1-dichloroethylene, 1,2-dichloroethylene, trichloroethylene, tetrachloroethylene, hexachlorobutane Alkene, benzene, toluene, xylene, ethylbenzene, styrene, chlorobenzene, 1,2-dichlorobenzene, 1,4-dichlorobenzene, trichlorobenzene, hexachlorobenzene, epoxy chloropropene Alkane, acrylamide, microcystins-LR, microcystins-RR, dichlorvos, dimethoate, parathion, methyl parathion, 2,4-d, seven Chlorine, chlorpyrifos, bentazone, glyphosate, atrazine, carbofuran, deltamethrin, pentachlorophenol, malathion, 2-methylisodecyl alcohol, soil odor , ozone, chlorine dioxide, chloroform, tribromomethane, dichloromonobromomethane, monochlorodibromomethane, dichloromethane, dichloroacetic acid, Trichloroacetic acid, monochloroacetic acid, monobromoacetic acid, monochloromonobromoacetic acid, dibromoacetic acid, dichloromonobromoacetic acid, monochlorodibromoacetic acid, tribromo 32 test methods for 62 indicators such as acetic acid, Giardia, and Cryptosporidium; --- Deleted three test methods for four inorganic indicators such as barium, sodium, calcium and magnesium; --- Removed 1,1-dichloroethylene, 1,1,1-trichloroethane, 1,1,2-trichloroethane, tribromomethane, 1,1,2,2-tetrachloroethane 5 items 2 test methods for hairy organic matter; --- Revised silica, trichlorfon, dichlorvos, dimethoate, parathion, methyl parathion, phenol, 4-nitrophenol, 3-methylphenol, 2,4-di Chlorophenol, 2,4,6-trichlorophenol, pentachlorophenol, naphthalene, fluoranthene, benzo (b) fluoranthene, benzo (k) fluoranthene, benzo (a) pyrene, benzo (ghi) Oh, 茚[1,2,3-c,d]芘, Streptococcus faecalis, sulfite-reduced anaerobic bacteria (C. brevis) spores and mutagens 22 9 test methods for the indicator. This standard was proposed by the Institute of Standardization of the Ministry of Housing and Urban-Rural Development. This standard is under the jurisdiction of the Municipal Water Supply and Drainage Standardization Technical Committee of the Ministry of Housing and Urban-Rural Development. This standard is drafted by. China Urban Planning and Design Institute, National Urban Water Supply Monitoring Network, Beijing Monitoring Station, National City Water quality monitoring online sea monitoring station, national urban water supply quality monitoring network Harbin monitoring station, national urban water supply quality monitoring network Shenzhen supervision Station, Chinese Academy of Sciences Ecological Environment Research Center, National Urban Water Supply Quality Monitoring Network Jinan Monitoring Station, National Urban Water Supply Quality Monitoring Network Zhengzhou Monitoring Station, National Urban Water Supply Quality Monitoring Network Guangzhou Monitoring Station, National Urban Water Supply Quality Monitoring Network Tianjin Monitoring Station. Participated in the drafting of this standard. National Urban Water Supply Monitoring Network Wuhan Monitoring Station, National Urban Water Supply Monitoring Network, Hangzhou Monitoring Station, National Urban Water Quality Monitoring Network Dalian Monitoring Station, National Urban Water Supply Quality Monitoring Network Shijiazhuang Monitoring Station, National Urban Water Supply Quality Monitoring Network Taiyuan Monitoring Station, National Urban Water Supply Quality Monitoring Network Wuxi Monitoring Station, National Urban Water Supply Monitoring Network Hefei Monitoring Station, Country Urban Water Supply Quality Monitoring Network Fuzhou Monitoring Station, National Urban Water Supply Quality Monitoring Network Xiamen Monitoring Station, National Urban Water Supply Quality Monitoring Network Xi'an Monitoring station, national urban water supply quality monitoring network Zhuhai monitoring station, national urban water supply quality monitoring network Foshan monitoring station, national urban water supply Quality monitoring network coastal monitoring station, national urban water supply quality monitoring network Qingdao monitoring station, national urban water supply quality monitoring network Urumqi monitoring Station, National Urban Water Quality Monitoring Network Lanzhou Monitoring Station, National Urban Water Supply Monitoring Network Yinchuan Monitoring Station, National Urban Water Supply Monitoring Changsha Monitoring Station, National Urban Water Quality Monitoring Network Nanchang Monitoring Station, National Urban Water Supply Monitoring Network Zhuzhou Monitoring Station, National City City Water Supply Quality Monitoring Network Kunming Monitoring Station, National Urban Water Supply Quality Monitoring Network Chongqing Monitoring Station, National Urban Water Supply Quality Monitoring Network Chengdu Supervision Station, National Urban Water Quality Monitoring Network Nanjing Monitoring Station, Beijing Disease Prevention and Control Center, Guangzhou Water Quality Monitoring Center, Guangdong Province Water quality monitoring network Shunde monitoring station, Zhejiang Pinghu City Center for Disease Control and Prevention. The main drafters of this standard. Shao Yisheng, He Qin, Gui Ping, Li Zonglai, Gu Weina, Lin Aiwu, Zeng Ciyuan, Jia Lili, Lu Yixin, Yu Jianwei, Jia Ruibao, Lin Biao, Liu Jing, Shi Wei, Luo Wenbin, Liu Bo, Yang Min, Sun Yuhua, Zhou Bingjian, Wang Dan, Mu Xianfeng, Zhang Lingyun, Zhang Lijian, Zhang Dongqing, Dou Chunju, Huang Huiyu, Li Lin, Jin Hong, Wang Lei, Yu Chao, Zhou Ming, Zhu Lingmin, Li Dongmei, Li Hongyan, Zhang Xiaoxia, Wu Xuefeng, Chai Wen, Luo Liang, Qu Li, Jiang Xu, Xu Chenghao, Xu Rong, Zhang Wei, Song Luyang, Liang Tao, Wang Xinying, Luo Peng, An Wei, Meng Xianghui, Wang Xiang, Zhang Jianhua, Cui Jianhua, Xu Xin, Feng Fulai, Xiang Hua, Lu Feng, Dong Ruisheng, Lin Zhaohui, Zhang Xudong, Lin Biao. The previous versions of the standards replaced by this standard are. ---CJ/T 141-2001; ---CJ/T 142-2001; ---CJ/T 143-2001; ---CJ/T 144-2001; ---CJ/T 145-2001; ---CJ/T 146-2001; ---CJ/T 147-2001; ---CJ/T 148-2001; ---CJ/T 149-2001; ---CJ/T 150-2001. Town water supply quality standard test method

1 Scope

This standard specifies the terms and definitions, general rules, inorganic and sensory traits indicators, organic matter indicators, pesticides for urban water supply testing methods. Test methods for indicators, indicators of odorant substances, indicators of disinfectants and disinfection by-products, microbial indicators and comprehensive indicators. This standard applies to the water quality testing of urban water supply and its source water.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 5750 (all parts) Standard test method for drinking water GB/T 6682 Analytical laboratory water specifications and test methods GB 15603 General rules for the storage of common dangerous chemicals GB 19489 General requirements for biosafety GB/T 27476.1 Safety of testing laboratories - Part 1. General GB/T 27476.5 Testing laboratory safety - Part 5. Chemical factors

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Minimum detection mass concentration minimumquantitativedetectionlimit The minimum mass concentration of the substance to be tested can be accurately quantified by a specific method on the premise that the limit error satisfies the predetermined requirement. 3.2 Precision precision Under the specified conditions, the degree of agreement between the multiple determination results independently of each other. 3.3 Accuracy The degree of agreement between the measured result and the measured true or reference value.

4 General

4.1 Selection of test methods This standard is a supplement to GB/T 5750. When there are two or more inspection methods for the same indicator, it can be based on the equipment. And the technical conditions select the applicable method.