CJ 266-2008: Safety regulations for cold potable water meters
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
CJ 266-2008English259 Add to Cart 3 days [Need to translate] Safety regulations for cold potable water meters Valid CJ 266-2008

PDF similar to CJ 266-2008


Standard similar to CJ 266-2008

GB/T 18920   GB/T 18921   GB/T 18919   CJ/T 270   CJJ 266   CJ/T 256   

Basic data

Standard ID CJ 266-2008 (CJ266-2008)
Description (Translated English) Safety regulations for cold potable water meters
Sector / Industry Urban Construction Industry Standard
Classification of Chinese Standard P40
Classification of International Standard 91.140
Word Count Estimation 10,166
Date of Issue 2008-01-07
Date of Implementation 2008-06-01
Older Standard (superseded by this standard) CJ 3064-1997
Quoted Standard GB/T 778.1-1996; GB/T 778.3-1996; GB/T 1176; GB/T 1348; GB/T 1804-2000; GB/T 2516; GB/T 7306.1; GB/T 7307; GB/T 9439; GB/T 12230; GB/T 14976; JB/T 8480-1996
Regulation (derived from) Chinese Ministry of Construction Bulletin No. 780
Issuing agency(ies) Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary This standard specifies the safety of drinking water, cold water requirements and test methods. This standard applies to common flow range of 0. 6m3/h ~ 4000m3/h (with GB/T 778. 1-1996 provisions of Article 4. 1 of the corresponding nominal diameter of 15mm ~ 800mm), maximum allowable working pressure (MAP) and greater than or equal to 1MPa maximum allowable operating temperature (MAT) at 30��C for different measurement levels of water. This standard only applies to water meters Case material such as pressure parts for the metal water meter.

CJ 266-2008: Safety regulations for cold potable water meters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety regulations for cold potable water meters ICS 91.140 P40 People's Republic of China urban construction industry standards Replacing CJ 3064-1997 Drinking water cold water meter safety rules Posted.2008-01-07 2008-06-01 implementation Ministry of Construction of People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1

3 safety requirements

3.1 water pressure requirements 1 3.2 parts material requirements 1 3.3 pressure parts size and weight requirements 1 4 meter pressure test method 2 Appendix A (Normative) Connection Nuts, Fittings and Wet Metering Cover 3 A. 1 Description 3 A. 2 size and weight 3

Foreword

This standard is the national standard GB/T 778.1-1996 "cold water meter Part 1. Specification" (eqv ISO 4064-1..1993 "closed Measurement of water flow in pipes - Part 1. Specifications "), GB/T 778.3-1996" Cold water meters - Part 3. Test methods and tests Equipment "(idt ISO 4064-3. 1983" Measurement of water flow in closed conduits - Drinking cold water meters - Part 3. Test methods and test equipment Prepared ") the specific requirements of the safety requirements. Chapter 3 of this standard is mandatory. This standard and CJ 3064-1997 "drinking water drinking safety regulations" compared to the main changes are as follows. 1) meter diameter expanded to 800mm; 2) increase the material requirements of the water meter case; 3) The individual dimensions of the pipe joint and the wet water meter cover have been adjusted; 4) Increased water meter material strength, durability and all water access parts and protective materials requirements. Appendix A of this standard is normative appendix. This standard is proposed by the Ministry of Construction standard quota research institute. This standard by the Ministry of Water Supply and Drainage Products Standardization Technical Committee. This standard was drafted. Beijing Water Group Beijing Katherine meter limited liability company, Ningbo Water Meter Co., Ltd., Fuzhou meter factory, Shanghai Water Meter Factory, Shanghai Water Supply Equipment Engineering Co., Ltd., Ningbo East China Sea Instrument Co., Ltd. water meter, water meter limited liability company, Suzhou Water Meter Co., Ltd., Lianyungang Lianli Water Meter Co., Ltd., Jiangxi Sanchuan Meter Co., Ltd., Nanjing Water Company Water Table Factory, Tianjin Jin Instrument Co., Ltd., Tianjin Lianchang meter Technology Co., Ltd., Wuhan Arad meter Co., Ltd., Zhejiang Yongling water supply Equipment Co., Ltd., Shandong Linyi Rongxiang Water Meter Manufacturing Co., Ltd., Shandong Linyi Lomon meter Manufacturing Co., Ltd., Guangzhou Water Company water Watch factory, Qinhuangdao Qin Xiang Special Glass Co., Ltd., Ningbo Zhongjing Copper Co., Ltd., Hangzhou Water Meter Co., Ltd. The main drafters of this standard. Manchu Han, Ye Xian Cang, Chen Zhang, Chen Gujian, Fan Yonglian, (the following arranged by name stroke) Kong Huaqing, Wang Rulun, Wang Jianyao, Feng Yi, Liu Li, Liu Guohua, Li Yinming, Li Zhiguang, Chen Zhengrong, Lin Zhiliang, Yang Aide, Yang Chuhong, Zhang Xuelin, Hu Zhongquan, Dai Xuejun, Tao Jianhua, Zhan Shouyu, Xiejian Liang. This standard was first released in.1997, the first revision in.2007. This standard from the date of implementation instead of CJ 3064-1997. Drinking water cold water meter safety rules

1 Scope

This standard specifies the drinking water cold water meter safety requirements and test methods. This standard applies to the common flow range of 0.6m3/h ~ 4000m3/h (with GB/T 778.1-1996 the provisions of Article 4.1 Should be the nominal diameter of 15mm ~ 800mm), the maximum allowable working pressure (MAP) greater than or equal to 1MPa and the maximum allowable working temperature (MAT) is a 30 ° C water meter of different metering levels. This standard applies only to pressure gauges such as water meters for the metal material of the water meter.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. All dated references, which are subsequently owned Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to reach an agreement based on this standard research Whether you can use the latest versions of these files. For undated references, the latest version applies to this standard. GB/T 778.1-1996 cold water meter - Part 1. Specification (eqv ISO 4064-1..1993) GB/T 778.3-1996 Cold water meter - Part 3. Test methods and test equipment (idt ISO 4064-3. 1983) GB/T 1176 casting copper alloy technical conditions (neq ISO 1338. 1977) GB/T 1348 ductile iron parts GB/T 1804-2000 General tolerances Tolerances for linear and angular dimensions without tolerance (eqv ISO 2768-1. 1989) GB/T 2516 ordinary thread limit deviation GB/T 7306.1 55 ° sealing pipe thread Part 1. Cylindrical internal thread and conical thread (eqv ISO 7-1..1994) GB/T 7307 55 ° non-sealed pipe thread (eqv ISO 228-1..1994) GB/T 9439 gray cast iron GB/T 12230 general valve stainless steel castings technical conditions GB/T 14976 stainless steel seamless pipe for fluid transport Tempered glass for wet water meters

3 safety requirements

3.1 water pressure requirements The meter should be guaranteed to work safely under the maximum allowable working pressure. 3.2 parts material requirements 3.2.1 All water contact parts and protective materials should be non-toxic, non-polluting, non-bioactive materials. 3.2.2 The materials used to make the water meter should have sufficient strength and durability to meet the requirements of the water meter. Pressure parts allowed to be used with the following phases Same or better material. 3.2.3 pressure parts of the material requirements shown in Table 1. 3.2.4 gray cast iron and ductile iron castings should be added to the inner surface of the protective material. 3.2.5 gray cast iron case in this standard approved after the implementation of 2 years shall not be installed in the drinking water network and the new dress. 3.3 pressure parts size and weight requirements 3.3.1 The size and weight of the connecting nut produced by casting lead brass shall comply with the requirements of Appendix A2.1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CJ 266-2008_English be delivered?

Answer: Upon your order, we will start to translate CJ 266-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CJ 266-2008_English with my colleagues?

Answer: Yes. The purchased PDF of CJ 266-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.