YY/T 0746-2021 English PDFUS$119.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0746-2021: Particular specifications for medical X-ray equipment install on the vehicle Status: Valid YY/T 0746: Historical versions
Basic dataStandard ID: YY/T 0746-2021 (YY/T0746-2021)Description (Translated English): Particular specifications for medical X-ray equipment install on the vehicle Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C43 Word Count Estimation: 6,612 Issuing agency(ies): State Drug Administration YY/T 0746-2021: Particular specifications for medical X-ray equipment install on the vehicle---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Particular specifications for medical X-ray equipment install on the vehicle ICS 11.040.50 C43 People's Republic of China Pharmaceutical Industry Standards Replace YY/T 0746-2009 Special technical requirements for vehicle-mounted medical X-ray diagnostic equipment Released on 2021-03-09 2022-04-01 implementation Issued by the National Medical Products Administration ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces YY/T 0746-2009 "Special technical conditions for vehicle-mounted X-ray machines". This standard is compared with YY/T 0746-2009 The main changes are as follows. ---Modified the "normative references" (see Chapter 2, Chapter 2 of the.2009 edition); ---Modified "Terms and Definitions" (see Chapter 3, Chapter 3 of the.2009 edition); --- Modified "Classification and Composition" (see Chapter 4, Chapter 4 of the.2009 edition); --- Modified "Regulated by the product standard" to "Regulated by the manufacturer" (see Chapter 5 and Chapter 6, Chapter 5 and Chapter 6 of the.2009 edition chapter); ---Modified "electric power", "loading factors and control", "imaging performance", "software function", "mechanical device performance", and "high-voltage cable plugs and plugs". "Seat", "Appearance" and "Safety" requirements (see 5.2, 5.3, 5.4, 5.5, 5.6, 5.7, 5.12, 5.14 of the.2009 edition); --- "Vehicle" is changed to "Space requirements of the vehicle" (see 5.3, 5.8 in the.2009 edition); ---Modified the "input power supply" (see 5.4, 5.9 of the.2009 edition); ---Modified "installation stability" (see 5.5, 5.10 of the.2009 edition); ---Modified the "environmental test" (see 5.7, 5.13 of the.2009 edition); --- Modified 6.1.2a) [see 6.1.2a), 6.1.2a) of the.2009 edition]; ---Modified "electric power", "loading factors and control", "imaging performance", "software function", "mechanical device performance", and "high-voltage cable plugs and plugs". The test methods for "seat", "appearance" and "safety" (see 6.2, 6.3, 6.4, 6.5, 6.6, 6.7, 6.12, 6.14 of the.2009 edition); --- Modify the title of "carriage vehicle" (see 6.3, 6.8 of the.2009 edition); ---Modified the "input power supply" (see 6.4, 6.9 in the.2009 edition); ---Modified the "environmental test" (see 6.7, 6.13 of the.2009 edition). Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is organized by the National Medical Electrical Appliance Standardization Technical Committee Medical X-ray Equipment and Apparatus Sub-Technical Committee (SAC/TC10 SC1) Centralized. Drafting organizations of this standard. Liaoning Provincial Medical Device Inspection and Testing Institute, Shenzhen Akerui Electric Co., Ltd., Shenzhen Anke High Technology Co., Ltd. Limited company. The main drafters of this standard. Shan Xu, Wang Jianjun, Shi Jisheng, Wang Xiaotong, Ma Yue, Xie Tao, Liu Peng. The previous versions of the standard replaced by this standard are as follows. ---YY/T 0746-2009. Special technical requirements for vehicle-mounted medical X-ray diagnostic equipment1 ScopeThis standard specifies the terms and definitions, classification and composition, requirements and test methods of vehicle-mounted medical X-ray diagnostic equipment. This standard applies to medical X-ray diagnostic equipment that is installed on a transport vehicle and the transport vehicle is in a stationary state for diagnosis.2 Normative referencesThe following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB 9706.18 Medical electrical equipment Part 2.Special requirements for the safety of X-ray computed tomography equipment GB/T 10149 Terms and Symbols for Medical X-ray Equipment GB/T 19042.1-2003 Evaluation and routine tests in medical imaging departments Part 3-1.For X-ray photography and fluoroscopy systems X-ray equipment imaging performance acceptance test GB/T 19042.5-2006 Evaluation and routine tests in medical imaging departments Part 3-5.X-ray computed tomography equipment Preparation imaging performance acceptance test YY/T 0291-2016 Environmental requirements and test methods for medical X-ray equipment YY/T 0310-2015 General technical conditions for X-ray computed tomography equipment YY/T 0706-2017 Special technical conditions for breast X-ray machine YY/T 0741-2018 Special technical conditions for digital photography X-ray machines YY/T 0742-2021 Special technical conditions for gastrointestinal X-ray machine YY/T 0745-2009 Special technical requirements for remote X-ray machine3 Terms and definitionsGB 9706.18, GB/T 10149, GB/T 19042.1-2003 and GB/T 19042.5-2006 defined as well as the following terms and The definition applies to this document. 3.1 On-board medical X-ray diagnostic equipment medicalX-ray equipmentinstalonthevehicle Medical X-ray diagnostic equipment installed on a mobile transport vehicle, used to carry out X-rays on sites far away from the hospital under mobile conditions Line diagnostic check.4 Classification and composition4.1 Classification According to the product's intended use and/or product structure, it can be divided into. a) X-ray computed tomography equipment; b) Mammography camera; c) Digital photography X-ray machine; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0746-2021_English be delivered?Answer: Upon your order, we will start to translate YY/T 0746-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0746-2021_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0746-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YY/T 0746-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0746-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |