YY/T 0794-2022 (YY/T 0794-2010) English PDF
Price & Delivery
US$315.00 · In stock · Download in 9 secondsYY/T 0794-2010: Particular specifications for computed radiography device
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete
YY/T 0794: Historical versions
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| YY/T 0794-2022 | 559 | Add to Cart | 5 days | Particular specifications for computed radiography device | Valid |
| YY/T 0794-2010 | 315 | Add to Cart | Auto, 9 seconds. | Particular specifications for computed radiography device | Obsolete |
Click to Preview this PDF
YY/T 0794-2010: Particular specifications for computed radiography device
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0794-2010YY PHARMACEUTICAL INDUSTRY STANDARD ICS 11.040.50 C 43 Particular specifications for computed radiography device Issued on: DECEMBER 12, 2010 Implemented on: JUNE 01, 2012 Issued by. China Food and Drug Administration
Table of Contents
Foreword... 3 1 Scope... 4 2 Normative references... 4 3 Terms and definitions... 4 4 Composition... 6 5 Requirements... 6 6 Test method... 9 Appendix A (Informative) Comprehensive test scale... 14 Appendix B (Informative) Threshold contrast test phantom... 16 Appendix C (Informative) Justification... 28 Particular specifications for computed radiography device1 Scope
This standard specifies the terms and definitions, composition, requirements, test methods of computed radiography device (hereinafter referred to as CR). This standard applies to CR. The device uses an image plate that forms a "latent image" after X-ray irradiation; forms a digital X-ray image by scanning the "latent image" on the image plate. CR is used to obtain digital diagnostic images after X-ray device photography, excluding X-ray photography device.2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1.General requirements GB 7247.1-2001 Safety of laser products - Part 1.Equipment classification, requirements and users guide YY/T 0291-2007 Environmental requirements and test methods for medical x-ray equipment YY/T 0796-2010 Medical electrical device - Exposure index of digital X-ray imaging system - Part 1.Definition and requirements of general X-ray photography DICOM 3.0 Medical digital imaging and communication standard (third edition) IEC 60788 Medical electrical device - Glossary of terms and definitions3 Terms and definitions
The terms and definitions as defined in IEC 60788 as well as the following terms and definitions apply to this document. It is a phenomenon that the potential image information of X-ray photography recorded by the IP plate decreases with time before being read.4 Composition
CR is mainly composed of imaging plate, scanning device, control processing device.5 Requirements
5.1 Working conditions 5.1.1 Environmental conditions Unless otherwise specified in the product standard, the working environment conditions of CR shall meet. a) Ambient temperature. 10 °C ~ 40 °C; b) Relative humidity. 30% ~ 75%; c) Atmospheric pressure. 700 hPa ~ 1060 hPa. 5.1.2 Power supply conditions The working power supply conditions of CR shall meet. a) For the power supply voltage and the number of phases specified in the product standard, the fluctuation of the grid voltage shall not exceed ±10% of the nominal value; b) Power frequency. 50 Hz ± 1 Hz (products for export are specified by the manufacturer); c) The power capacity as specified by the product standard. 5.2 Effective imaging area The product standard shall specify the maximum size and deviation of the effective imaging area of the IP plate in the X and Y directions; the deviation shall not exceed ±5% of the nominal value. 5.3 Bit-depth The product standard shall specify the bit-depth when the image is acquired; it shall not be less than 12 bits/pixel. Observe the exposed image of the specified test scale; there shall be no geometric distortion of image. 5.12 Security of management information There shall be software measures taken to ensure the privacy and reliability of patient data. 5.13 Information management There shall be software measures to manage patient information, at least with the functions of registration, modification, deletion, query, statistics, backup management. 5.14 Film printing It has the function of transferring images to a film printer. 5.15 Medical digital imaging and communication standards If it conforms to the DICOM 3.0 standard or other network communication standards, it shall provide a compliance statement in the accompanying documents. 5.16 Noise The noise generated during operation under working conditions shall not exceed 70 dB (A weighting network) (not including non-continuous and non- periodic noise within 3 s). 5.17 Appearance The appearance shall be neat and beautiful; the surface shall be smooth and clean; color shall be uniform. There shall be no defects such as scars, cracks, etc. 5.18 Environmental test It shall meet the requirements of YY/T 0291-2007 (except IP plate). In the initial, intermediate or final testing, the device shall be able to be used normally without abnormal phenomena. 5.19 Safety It shall meet the requirements of GB 4793.1-2007 and GB 7247.1-2001. The test steps are as follows. a) Select appropriate loading conditions, so that the X-ray irradiation field covers the entire IP plate; b) Under the conditions of the effective imaging area, pixel size and bit-depth of the specified IP plate, measure the time from when the IP plate is placed in the CR scanning device to the time when the image that can be used for medical diagnosis is completely displayed on the display; c) The effective imaging area, pixel size and bit-depth of the IP plate shall be recorded together with the measurement results. 6.5 Number of IP plates processed per hour The test steps are as follows. a) Select five IP plates of the same specification; b) Start timekeeping when the first IP plate is inserted into the card slot of the CR scanning device, until the last IP plate is withdrawn from the CR. The operation time shall be shortened as much as possible for the part of the CR that requires manual operation; c) Measure the total time required to complete the entire process of the IP plate’s processing cycle for 5 consecutive times; calculate the number of IP plates processed in 1 h; the result takes an integer. 6.6 Threshold contrast Use the test method specified in the product standard for testing, or test according to the following methods as recommended by this standard, the steps are as follows. a) Use the threshold contrast phantom in Appendix B and select appropriate loading conditions, to obtain the clearest phantom image; b) Refer to Appendix B, to obtain the reciprocal of the image quality value through calculation; c) Repeat steps a) ~ b) to measure 3 times; take the average value; d) The measurement conditions, effective imaging area of the IP plate, pixel size, bit-depth shall be recorded together with the results. 6.7 Spatial resolution Load according to the loading conditions as specified in the product standard or automatic exposure control; meanwhile adjust the brightness and contrast to other similar test scales; b) According to the loading conditions as specified in the product standard, the X-ray’s irradiation field covers the entire IP plate; the reference axis shall be perpendicular to the IP plate, to expose the IP plate; c) Scan the image of the IP plate; make visual inspection; there is no obvious geometric distortion. 6.12 Security of management information Verify by checking the device. 6.13 Information management Verify by checking the device. 6.14 Film printing Verify by inspection. 6.15 Medical digital imaging and communication standards Verify by checking its declaration of conformity. 6.16 Noise The sound level meter’s probe is 1 m away from the surface of the CR system and 1.5 m from the floor. The sound level meter "A" class weighting network is used for measurement; use the maximum noise value for calculation. 6.17 Appearance Observe visually. 6.18 Environmental test It is performed according to the requirements of YY/T 0291-2007. 6.19 Security The inspection shall be carried out according to the requirements of GB 4793.1- 2007 and GB 7247.1-2001.Appendix C
(Informative) Justification C.1 Description about 3.1, 3.2, 3.3 Photostimulable Luminescence (PSL) is the basis of CR imaging. This feature makes CR different from other medical imaging device. The imaging layer in the IP plate is a layer of barium halide fluoride crystals containing divalent europium ions. The compound in the crystal layer is irradiated by X-rays; the fluorescent substance absorbs the incident X-rays and stores its energy, forming a latent image and storing it in the crystal, which is a simulated image (this is the first excitation); then the laser beam scans the fluorescent screen with latent image (second excitation); the information stored on the screen is radiated from the converted light signal. The wavelength of the helium-neon laser beam used is 670 nm ~ 690 nm. The surface of the IP plate is scanned sequentially in the direction perpendicular to the IP plate. The phosphor refracted from the IP plate is excited by the secondary excitation (called Photostimulable Luminescence, PSL), producing fluorescence. The intensity of the fluorescence is precisely proportional to the latent image energy at the first excitation. The fluorescence is collected and guided along the high- efficiency light guide filmed by laser scanning; enters the photomultiplier tube; is amplified by the A/D converter into a digital signal and stored on the computer. The computer can further process the stored images and display them. The signal on the storage screen can be erased by strong light for the next use. CR does not include X-ray machines. Its main purpose is to replace the traditional X-ray screen-film system, to realize the digital processing and storage of diagnostic images. C.2 Description of 3.4 and 3.5 For the specifications of the IP plate, its effective imaging area, bit-depth, pixel size determines the image quality of X-ray digital images from the hardware. C.3 Descriptions of 5.6 Image quality figure (IQF) is a method of quantifying images for threshold contrast evaluation. The following methods can be used for threshold contrast evaluation. a) Draw a curve that passes through the threshold area, which is called the contrast-detail curve. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.