SN/T 2592.6-2011 English PDFUS$209.00 · In stock  
  Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 2592.6-2011: Determination of organotin compounds in electrical and electronic equipment. Part 6: Inductively coupled plasma atomic emission spectrometry Status: Valid 
 Basic dataStandard ID: SN/T 2592.6-2011 (SN/T2592.6-2011)Description (Translated English): Determination of organotin compounds in electrical and electronic equipment. Part 6: Inductively coupled plasma atomic emission spectrometry Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: L04 Classification of International Standard: 31.020 Word Count Estimation: 8,834 Date of Issue: 2011-09-09 Date of Implementation: 2012-04-01 Quoted Standard: GB/T 6682 Regulation (derived from): National Quality Inspection (2011) 492; industry standard filing Notice 2012 No. 4 (No. 148 overall) Issuing agency(ies): General Administration of Customs Summary: This standard specifies the electrical and electronic products, organic tin by inductively coupled plasma atomic emission spectrometric method. This standard applies to electrical and electronic products, plastic components in the determination of organic tin. SN/T 2592.6-2011: Determination of organotin compounds in electrical and electronic equipment. Part 6: Inductively coupled plasma atomic emission spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of organotin compounds in electrical and electronic equipment.Part 6. Inductively coupled plasma atomic emission spectrometry People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination of organotin compounds in electrical and electronic products Part 6. Inductively coupled plasma atomic Emission Spectrometry Part 6. Inductivelycoupledplasmaatomicemissionspectrometry Issued on. 2011-09-09 2012-04-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released Foreword"Determination of electrical and electronic products of organic tin compounds" SN/T 2592 series of standards is divided into six parts. --- Part 1. gas chromatography; --- Part 2. Fourier transform infrared spectroscopy screening method; --- Part 3. Inductively Coupled Plasma Mass screening; --- Part 4. Liquid chromatography - mass spectrometry; --- Part 5. gas chromatography - mass spectrometry; --- Part 6. Inductively coupled plasma atomic emission spectrometry. This section "Measurement of electrical and electronic products, organic tin compounds" SN/T 2592 series of standards Part 6. This section drafted in accordance with GB/T 1.1-2009 requirements given. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section is responsible for drafting unit. People's Republic of China Shandong Entry Inspection and Quarantine Bureau, People's Republic of China Guangdong Entry-Exit Inspection and Quarantine Bureau, People's Republic of China SZCIQ. The main drafters of this section. Cai hair, leaf Xi Wen, Niu Zengyuan, Li Jing, Xiaoda Hui, Chen Xiangyang. The first part of the Department of Inspection and Quarantine issued by industry standards. Determination of organotin compounds in electrical and electronic products Part 6. Inductively coupled plasma atomic Emission Spectrometry1 ScopeThis section SN/T 2592 specifies the electrical and electronic products of organic tin by inductively coupled plasma atomic emission spectrometric method. This section applies to the determination of electrical and electronic goods and plastic parts organotin.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Laboratory use specifications and test methods GB/T 6682 Analysis3 Method summaryAfter the sample microwave digestion inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis of the appropriate wavelength measured in digestion The emission intensity of liquid tin, against a standard curve to determine the concentration of tin, calculate the amount of tin in the sample.4 Reagents and materialsUnless otherwise specified, use only analytical reagent. The water used in line with two water GB/T 6682 regulations. 4.1 nitric acid (ρ = 1.4g/mL). pure class distinctions. 4.2 Hydrogen peroxide (30%). pure class distinctions. 4.3 fluoroborate. 4.4 tin standard stock solution (100mg/L). 10% HCl matrix. 4.5 nitrate and fluoride boric acid mixed solution. Take 5mL nitric acid (4.1) and 1mL fluoride boric acid (4.3) in an appropriate amount of water, then diluted to 100mL. 5. Apparatus 5.1 Inductively coupled plasma atomic emission spectrometer. working gas is argon purity ≥99.99%. 5.2 Microwave Digestion System. equipped with a temperature or pressure safety control device. 5.3 Balance. a sense of the amount of 0.1mg. 5.4 Freezing mills. Step 6 Analysis 6.1 Sample Preparation The sample was cut to 3mm × 3mm or less pieces, then frozen and ground to a particle size less than 1mm powder-like stand. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 2592.6-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 2592.6-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 2592.6-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 2592.6-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |