JY/T 0042-2019 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JY/T 0042-2019: Teaching thermistor thermometer Status: Valid
Basic dataStandard ID: JY/T 0042-2019 (JY/T0042-2019)Description (Translated English): Teaching thermistor thermometer Sector / Industry: Education Industry Standard (Recommended) Classification of Chinese Standard: Y51 Word Count Estimation: 9,989 Date of Issue: 2019-04-08 Date of Implementation: 2019-09-01 Older Standard (superseded by this standard): JY 42-1979 Regulation (derived from): Natural Resources Department Announcement No. 7 of 2019 Issuing agency(ies): Ministry of Education of the People's Republic of China JY/T 0042-2019: Teaching thermistor thermometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Teaching thermal thermometer) ICS 03.180 Y 51 Education Industry Standard of the People's Republic of China Replacing JY/T 42-1979 Teaching Thermometer Teaching thermistor thermometer Published on April 04,.2019 2019--09--01 Implementation Published by the Ministry of Education of the People's Republic of China JY ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces JY/T 42-1979 "Thermal Thermometer". Compared with JY/T 42-1979, major technical changes It is as follows. -Modified the standard name; -Modified to linear indication, 10-division dial of analog indicating meter for borrowing can be borrowed without special design (see 5.3.3, 1979 Annual version 1.3); -The temperature measurement range has been modified (see 5.3.1, 1.3 of the 1979 version); -The test methods and inspection rules have been modified (see Chapters 6 and 7, and Chapters 6 and 7 of the 1979 edition); -Removed the requirement that the temperature measuring element does not generate heat (see 1.3 of the 1979 edition); -Added specifications for digital demonstration meters (see 5.1.2); -Increased usable power supply (see 5.2); -Increased the indication error requirements (see 5.3.2); -Added indication of analog meter to distinguish measurement range (see 5.3.4); -Added sensing element types and lead handling (see 5.4); -Added terminal requirements (see 5.5); -Increased safety requirements (see 5.6); -Increased environmental test requirements (see 5.8); --- Increased the instruction manual requirements (see 8.1); -The definition and requirements of response time have been modified (see 4.1, 5.3.5, 2.2 of the 1979 version). Please note that some elements of this standard may involve patents. The issuer of this standard is not responsible for identifying these patents. This standard is proposed by the Basic Education Department of the Ministry of Education of the People's Republic of China. This standard is under the jurisdiction of the National Technical Committee for Educational Equipment Standardization (SAC/TC 125). This standard was drafted. Zhejiang Educational Technology Center. The main drafter of this standard. Ren Weide. This standard replaces JY/T 42-1979. The release of previous versions of this standard instead of the standard is as follows. --JY/T 42-1979. Teaching Thermometer1 ScopeThis standard specifies the classification and nomenclature, requirements, test methods, inspection rules, instruction manuals, signs, Packaging, transportation and storage. This standard applies to non-display thermosensitive thermometers used in middle school teaching experiments.2 Normative referencesThe following documents are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document. GB/T 2828.1-2012 Counting sampling inspection procedures. Part 1. Sampling plan for batch inspection inspection according to acceptance quality limit (AQL) GB 8898-2011 audio, video and similar electronic equipment safety requirements GB/T 16842-2016 test tool for protection and inspection of housing and people GB 18581-2009 Limit of harmful substances in solvent-based wood coatings for interior decoration materials JY/T 0001-2003 General quality requirements for teaching instruments and equipment products JY/T 0002 Inspection rules for teaching instruments and equipment products JY/T 0009-1990 Environmental requirements and test methods for electronic equipment for teaching JY/T 0026-1991 teaching instrument and teaching equipment product model naming method3 Classification and naming3.1 Product Classification According to the matched electric meter, it is divided into two types. analog meter and digital meter. 3.2 Model designation The product is named according to the provisions of JY/T 0026-1991. The model of the thermal thermometer is named. FT-RMW-W-A/D Product specifications, (with) analog/digital meters Product feature code, no meter (requires separate indicator meter) Product name Pinyin prefix, thermal temperature (meter) Product model classification code, general thermal instrument Model example 1. FT-RMW-WA stands for thermal thermometer, equipped with analog ammeter, universal instrument for heat. Model example 2. FT-RMW-WD stands for thermal thermometer, equipped with digital ammeter, and universal instrument for heat.4 Terms and definitionsThe following terms and definitions apply to this document. 4.1 Thermal response time When there is a step change in temperature, the time required for the output of the thermal element to change to 63% of the step change.5 Requirements5.1 Conditions of use 5.1.1 Relative humidity. ≤90%. 5.1.2 Specifications for analog meters. used with 500 μ A and 1 mA DC ammeters (changeable). Note. The demo meter for junior high school has a range of 500 μA, and the demo meter for high school has a range of 1 mA. Digital meter specifications. Used with digital ammeters that can measure 1 mA DC current. Note. The full scale of the digital ammeter is greater than 1 mA, such as 2 mA, 20 mA,.200 mA. 5.2 Using power 5.2.1 AC power or DC power (dry battery) can be used. 5.2.2 When using AC power, the AC power voltage is 220 V, the allowable error is ± 22 V; 50 Hz, the allowable error is 0.5 Hz. 5.2.3 When using a DC power supply, the voltage is determined by the product standard. 5.2.4 When using AC power, the length of the power cord should be 1.5 m to 2.0 m. 5.3 Measurement performance 5.3.1 Measurement range. FT-RMW-WA type, -10 ℃ ~ 100 ℃, should be divided into -10 ℃ ~ 0 ℃ and 0 ℃ ~ 100 ℃, since Dynamic commutation; FT-RMW-WD type, should not be less than -10 ℃ ~ 100 ℃. 5.3.2 Indication error. FT-RMW-WA type. -10 ℃ ~ 10 ℃. ± 3 ℃, 10 ℃ ~ 100 ℃. ± 2 ℃; FT-RMW-WD Type. ± 2 ℃. 5.3.3 FT-RMW-WA type should be able to use the meter's 10-division dial, and the displayed value should be linearly distributed. Note. If a scale with a full-scale value of 100 mA or 10 V is used, the full-scale value means 100 ℃, every 10 mA or every 1 V means 10 ℃, every 2 mA or 0.2 V means 2 ℃. FT-RMW-WD uses the DC current range. The displayed value of 1 mA means 100 ℃, and every 0.01 mA means 1 ℃. 5.3.4 FT-RMW-WA measurement temperature range indication should use light indication to distinguish the temperature measurement range below 0 ℃ or above 0 ℃. light White should be used, the panel should be marked with text, and the switching error should not be greater than 1.0 ℃. The FT-RMW-WD type should not have a switching function. 5.3.5 Thermal response time shall not be greater than 6 s. 5.4 Thermal element Semiconductor components should be used, and the leads should be insulated. After the thermal thermometer reaches thermal equilibrium, there should be no slow and automatic rise. Note. The leads are insulated to prevent electrical conduction between the leads after immersion in water. 5.5 Terminal 5.5.1 The outer diameter of the terminal is not less than 10 mm, the fixed screw M4, the stroke of the terminal cap is not less than 6 mm, and the plug is dual-use. Note. In addition to connecting wires, you can also use a plug in the middle of the terminal cap. 5.5.2 The fixing place of the terminal post and the base shall be provided with an anti-loosing spring washer, and the terminal cap shall not be unscrewed from the terminal post. 5.6 Security 5.6.1 When using AC power, all requirements of 5.6 shall be met. 5.6.2 Insulation resistance After the humidity test, it should not be less than 2 MΩ. 5.6.3 Electric strength 5.6.3.1 It shall comply with the primary winding to the shell of the power frequency transformer. 1500 V for Class I appliances and 3000 V for Class II appliances. 5.6.3.2 It shall comply with 3000 V between the primary winding and the secondary winding of the power frequency transformer. 5.6.4 Clearance and creepage distance Should comply with Class I appliances 3 mm, Class II appliances 6 mm. 5.6.5 Power cord Should comply with the cross-sectional area of not less than 0.5 mm2, the electrical strength of the conductor should comply with Chapter 16 of GB 8898-2011. Class I appliances should use single-phase three-pole plugs; Class II appliances should use single-phase two-pole plugs. 5.6.6 Electric shock prevention structure Dangerous live parts inside the power supply should not be accessible. 5.6.7 Fuse Block PC2 or PC3 should be used. 5.6.8 Protective earth wire for Class I appliances Use a yellow/green two-color line with a cross-sectional area of 0.75 mm2. The connection should use welding or spring washer screws, and the connection resistance should not be greater than 0.1 Ω, the contact should not use the metal fitting on the upper part of the boundary line of Appendix F of GB 8898-2011. 5.6.9 Cooling holes in the case Non-straight type should be used, or the diameter (or side length) of each hole should be no more than 4 mm. 5.6.10 Shell (including openings) resistant to external forces A force of 50 N applied perpendicular to the enclosure for 10 s should be applied without visible deformation. 5.6.11 Case coating If there is paint on the exterior of the cabinet, the content of harmful substances in the paint should comply with Table 1 in Chapter 4 of GB 18581-2009. 5.7 Appearance and workmanship Should comply with 6.10, 7.1, 7.2, 7.4, 7.6, 7.7 of JY/T 0001-2003. 5.8 Environmental test According to JY/T 0009-1990 4.3 Table 2 (all items).6 Test method6.1 Measurement performance 6.1.1 Test conditions It shall be tested under the following conditions. --Ambient temperature. 20 ℃ ± 5 ℃; -Relative humidity. (45 ~ 75)% RH; --AC power supply voltage. 220 V, allowable error ± 4.4 V; --AC power supply frequency. 50 Hz, allowable error ± 0.5 Hz. 6.1.2 Test instruments Use a second-class standard mercury thermometer or a second-class standard platinum resistance thermometer. Analog ammeter. ± 0.5%, digital ammeter. ± 0.5%. 6.1.3 Test procedure 6.1.3.1 Thermistors for analog meters use the following test steps. a) measuring room temperature; b) Put the probe of the tested thermosensitive thermometer and the standard thermometer in the constant temperature water tank at the same time, the temperature is between 0 ℃ and 10 ℃. After the current meter pointer of the meter is stabilized, read the current indication value, which should comply with 5.3.2; c) Put the probe of the tested thermometer and the standard thermometer in the constant temperature water tank at the same time, the temperature is 0 ℃, 50 ℃ and 100 ℃. Read the current indication value after the current meter pointer of the thermal thermometer is stable, which should comply with 5.3.2; d) Put the probe of the tested thermometer and the standard thermometer in the low-temperature tank at the same time, and set the temperature at -10 ℃ ≤ t < 0 ℃. Read the current indication value after the pointer of the ammeter of the sensitive thermometer is stable, which should comply with 5.3.2; e) Put a glass of water in the low temperature tank. When the temperature of the water drops below 0 ° C, insert the probe of the measured thermometer and the standard thermometer into the water at the same time. Cup, and take out the water cup, test the switching temperature indicated by the range of the thermosensitive temperature indication value, shall comply with 5.3.4. 6.1.3.2 The digital thermometer's thermal thermometer adopts the following test steps. the digital meter's DC current is 2 mA, and 1 mA is used as 100 ° C. Put the measured temperature probe and standard thermometer in the constant temperature water tank or low temperature tank at the same time, measure it at about -10 ℃, 0 ℃ ~ Measure two points in the range of 100 ℃ (respectively room temperature and 80 ℃ or more), should comply with 5.3.2. 6.1.3.3 Thermal response time test. Put a standard thermometer in a constant temperature water tank, and the water temperature in the constant temperature water tank should be above 80 ℃. Thermometer The probe was taken out from the low temperature tank and immediately put into the constant temperature water tank. The time when the thermometer shows 63% temperature should comply with 5.3.5. 6.1.3.4 The indication of the thermal thermometer shall be able to achieve the indicated value stability, and shall be consistent with 5.4 after stabilization. 6.1.3.5 After the test is completed, the power supply voltage of the AC-powered thermistor shall reach 198 V and 242 V, and it shall be able to work normally. 6.2 Security 6.2.1 Moisture test Press 10.2 in GB 8898-2011. 6.2.2 Insulation resistance The test with a 500 V insulation resistance meter shall comply with 5.6.2. 6.2.3 Electrical strength Test with a pressure tester for 1 min. There shall be no breakdown or flashover, which shall comply with 5.6.3. 6.2.4 Clearance and creepage distance According to GB 8898-2011 Appendix E, it should meet 5.6.4. 6.2.5 Power cord 6.2.5.1 Cross-sectional area Cut the power cord, remove the insulation, and calculate the diameter of the core wire with a spiral micrometer, which should meet 5.6.5 and 5.6.8. 6.2.5.2 Electrical strength According to GB 8898-2011 Chapter 16. 6.2.6 Shell resistance to external forces The test with the test tool C in accordance with GB/T 16842-2016 shall comply with 5.6.10. 6.2.7 Harmful substance content in coatings According to GB 18581, it should comply with 5.6.11. 6.2.8 Other items Based on sensory inspection, relevant requirements of 5.6 shall be met. 6.3 Length Measurement with vernier calipers with a division value of 0.02 mm shall meet the relevant requirements of Chapter 5. 6.4 Appearance and workmanship Sensory inspection shall meet the requirements of 5.7. 6.5 Other items The sensory inspection shall meet the relevant requirements of Chapter 5. 6.6 Environmental test According to JY/T 0009-1990, 4.5 ~ 4.9.7 Inspection rules7.1 Inspection classification Inspection is divided into factory inspection, type inspection and quality supervision inspection. 7.2 Inspection items The inspection items and inspection methods for factory inspection and type inspection are shown in Table 1. Table 1 Inspection items and methods for factory inspection and type inspection Serial number items require factory inspection type inspection Measuring performance Measurement range 5.3.1 ○ ● 2 Indication error 5.3.2 ● ● 3 dial 5.3.3 ○ ● 4 Temperature range indication 5.3.4 ○ ● 5 Thermal response time 5.3.5 ○ ● 6 Note thermal element 5.4 ○ ● 7 Terminal 5.5 ○ ● Insulation resistance 5.6.2 ● ● Electric strength 5.6.3 ○ ● Clearance and creepage distance 5.6.4 ○ ● Power cord 5.6.5, 5.2.4 ○ ● Electric shock prevention structure 5.6.6 ○ ● Fuse base 5.6.7 ○ ● Protective ground wire 5.6.8 ○ ● Case cooling holes 5.6.9 ○ ● Case resistance to external forces 5.6.10 ○ ● Chassis outer paint harmful content 5.6.11 ○ ● 10 Appearance and craftsmanship 5.7 ● ● 11 Environmental test 5.8-● Note. "●" in the table means all inspection items, "○" means sampling inspection items, and "-" means no inspection items. 7.3 Lot rules and sampling methods 7.3.1 The factory inspection shall be batched according to the delivery natural batch, and the type inspection shall be batched according to the stock array. 7.3.2 The sampling methods for factory inspection and type inspection are in accordance with the relevant provisions of JY/T 0002. 7.3.3 During the factory inspection, all the inspection items shall be inspected first, and samples shall be taken from the qualified products of all inspection items, and the inspection items shall be inspected. 7.4 Determination of nonconformity 7.4.1 The determination of sampling inspection shall be in accordance with the relevant provisions of JY/T 0002. 7.4.2 The failure criterion of a single sample shall be in accordance with the relevant provisions of JY/T 0002. 7.4.3 During the inspection of all inspection items, it shall be determined according to the unqualified criterion of a single sample. 7.4.4 5.3.2, 5.3.3, and 5.6 (all) of this standard are the main performance indicators. 7.5 Review rules 7.5.1 Unqualified batches and products can be submitted for inspection again after rework. 7.5.2 The re-inspection of sampling inspection items shall be carried out in accordance with 9.3 of GB/T 2828.1-2012. Protocol, general inspection level III, AQL value is 2.5. 7.6 Quality supervision inspection Refer to type inspection. 8 Instruction manuals, signs, packaging, transportation, storage 8.1 Instruction Manual 8.1.1 The instruction manual shall explain the product's electrical schematic diagram, component parameters, and adjustment component functions, positions, and adjustment methods. 8.1.2 The instruction manual should indicate the full-scale current value of the supporting demonstration meter. 8.2 Marking, packaging, transportation, storage Should comply with JY/T 0001-2003 Chapters 11 and 12. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JY/T 0042-2019_English be delivered?Answer: Upon your order, we will start to translate JY/T 0042-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JY/T 0042-2019_English with my colleagues?Answer: Yes. The purchased PDF of JY/T 0042-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |