GB/T 32890-2016 English PDF
 Basic dataStandard ID: GB/T 32890-2016 (GB/T32890-2016)Description (Translated English): Data model of protective relays based on IEC 61850 Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K45 Classification of International Standard: 29.240 Word Count Estimation: 109,118 Date of Issue: 2016-08-29 Date of Implementation: 2017-03-01 Regulation (derived from): National Standard Announcement 2016 No.14 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 32890-2016: Data model of protective relays based on IEC 61850---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Data model of protective relays based on IEC 61850 ICS 29.240 K45 National Standards of People's Republic of China IEC 61850 Engineering Application Model for Relay Protection 2016-08-29 released 2017-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I Introduction II 1 Scope 1 2 normative reference document 1 3 terms and definitions, abbreviations 1 4 General 2 5 configuration 2 6 IED Application Model Specification 5 Principles of Service Implementation 8 MMS dual network redundancy mechanism 12 9 GOOSE model and implementation specification10 SV model and implementation specification 11 IED Physical Port Description Specification 14 Repair and Handling Mechanism 13 Conformance Test 15 Appendix A (Normative Appendix) Process Layer Virtual Terminal CRC Check Code Generation Rule 17 Appendix B (informative) Principles of naming of related logical devices Appendix C (informative) Logical node class definition 1 24 Appendix D (informative) Logical Node Class Definition 2 40 Appendix E (normative appendix) Uniform expansion of common data class 55 Appendix F (Normative Appendix) Uniformly defined data types and data attribute types Appendix G (informative) Logical node prefix naming example Appendix H (Normative Appendix) Failure Report File Format 77 Appendix I (informative) Classification device model 81 Appendix J (normative) IED physical port description and station control layer dual network configuration example 95 Appendix K (informative) GOOSE, SV Engineering Profile Example 97 Appendix L (Normative Appendix) Service Consistency Requirements Appendix M (informative) Device logical node prefix example 104ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This standard is proposed by the China Electricity Council and centralized. The drafting of this standard unit. Zhejiang Electric Power Dispatching Control Center, Nanjing NARI Jubao Electric Co., Ltd., National Electricity Dispatching Control Center, China Southern Power Grid Power Dispatching Control Center, Shandong Electric Power Dispatching Control Center, Guangdong Electric Power Dispatching Control Center, Guangzhou Power Supply Bureau, China Power Scientific Research Institute, Zhejiang Electric Power Research Institute, Jiangsu Electric Power Research Institute, Xu Ji Electric Co., Ltd., Beijing Quartet Ji Bao Automation Co., Ltd., Guodian Nanjing Automation Co., Ltd., Guodian Nairui Technology Co., Ltd., Shandong Rongfu new information technology limited the company. The main drafters of this standard. Dai Xiaoxiang, Qiu Xuedao, Li Li, Xu Peng, Wang Song, Li Yiquan, Xu Qiangchao, Tang Yi, Jiang Jianning, Bu Qiangsheng, Liao Zeyou, Deng Junbo, Chen Fuding, Zhou Bin, Cui Dalin, Li Peng, Xiu Dawn.IntroductionTo standardize the application of IEC 61850 substation communication network and system international standards, to achieve the interoperability of manufacturers of equipment, improve IEC 61850 standard equipment production, commissioning, maintenance, operation of the convenience, specially developed relay protection IEC 61850 engineering application model. DL/T 860 is equivalent to the national standard with IEC 61850 standard, this standard uses DL/T 860, no other IEC 61850. IEC 61850 Engineering Application Model for Relay Protection1 ScopeThis standard specifies the configuration, model and service of the communication network and system of the substation when the DL/T 860 standard substation is used in the substation. Can, grammar, semantic uniformity, and the normative nature of the selected parameters, and specify the principles that should be followed in the practical application of the model. This standard applies to the DL/T 860 standard new substation automation system relay protection and related equipment engineering design and Application, transformation project reference implementation.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. DL/T 860 (all parts) substation communication networks and systems Technical specification for implementation of DL/T 860 3 terms and definitions, abbreviations 3.1 Terms and definitions The following definitions and definitions of the DL/T 860 and the following terms apply to this document. 3.1.1 Virtual terminal virtualterminator Describe the general name of the GOOSE, SV input, and output signal connection points of the IED device to identify the process layer, the interval layer and the interconnection Department of the secondary circuit signal, equivalent to the traditional substation screen terminal. 3.1.2 Virtual connection virtualconnection Using GOOSE, SV to achieve IED equipment between the information input and output connection, to identify the IED between the virtual terminal Access logic. 3.2 abbreviations The following abbreviations apply to this document. Acc Accelererate Accelerate BF circuit breaker failure (Breakerfailure) BRCB has cache report control block (BuferReportControlBloc) CID IED instance configuration file (ConfiguredIEDDescription) CT current transformer (Currenttransformer) Dev Device Err Error (Error) Fst First (First) GOOSE for Genericobjectorientedsubstationevents for Generic Objects ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32890-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32890-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32890-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32890-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |