Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 2900.12-2008 English PDF

US$799.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 2900.12-2008: Electrotechnical terminology -- Surge arresters, low-voltage surge protective devices and components
Status: Valid

GB/T 2900.12: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 2900.12-2008799 Add to Cart 6 days Electrotechnical terminology -- Surge arresters, low-voltage surge protective devices and components Valid
GB/T 2900.12-1989639 Add to Cart 5 days Electrotechnical terminology--Surge arrester Obsolete

Similar standards

GB/T 37404   DL/T 1000.1   GB/T 2694   GB/T 2900.17   GB/T 2900.19   GB/T 2900.20   

Basic data

Standard ID: GB/T 2900.12-2008 (GB/T2900.12-2008)
Description (Translated English): Electrotechnical terminology -- Surge arresters, low-voltage surge protective devices and components
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K49
Classification of International Standard: 29.080.99
Word Count Estimation: 36,396
Date of Issue: 2008-01-22
Date of Implementation: 2008-09-01
Older Standard (superseded by this standard): GB/T 2900.12-1989
Adopted Standard: IEC PAS 60099-7-2004, NEQ
Regulation (derived from): Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the arresters, voltage surge protector and its functional components of the jargon used, mainly for the development of standards, preparation of technical documents, translation of professional manuals, textbooks, books and other uses.

GB/T 2900.12-2008: Electrotechnical terminology -- Surge arresters, low-voltage surge protective devices and components


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrotechnical terminology. Surge arresters, low-voltage surge protective devices and components ICS 29.080.99 K49 National Standards of People's Republic of China Replacing GB/T 2900.12-1989 Electrotechnical terminology Surge arresters and low-voltage surge protector element Posted 2008-01-22 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 General terms 1 2 3 gapless metal oxide surge arresters 7 4 valve type arrester gap 11 5 surge protectors low voltage distribution systems 13 Surge protection telecommunications and signaling networks 6 16 7 gas discharge tube 18 8 avalanche breakdown diode 20 9 metal oxide varistors 22 10 Thyristor Surge limiter 24 Chinese index 33 English 39 Index

Foreword

This standard replaces GB/T 2900.12-1989 "Electrotechnical terminology lightning." This revision on the main technical reference content IEC PAS60099-7.2004 "arresters - Part 7. IEC Publication 60099-1,60099-4,60099-6,61643-1,61643-12, 61643-21,61643-311,61643-321,61643-331 and 61643-341 definitions and glossary "amendment. This standard compared with GB/T 2900.12-1989 main changes are as follows. --- According to GB/T 1.1-2000 "Standardization Guide Part 1. Structure and rules are written standard" and GB/T 20001.1-2001 "Rules for drafting standards - Part 1. The term" be written. --- In the case of term does not contradict with the IEC , reservations arrester term domestic usual while increasing some new terminology. --- Increased surge protector term low voltage distribution systems. --- Increased surge protector term telecommunications and signaling networks. --- Increasing the gas discharge tube terminology. --- Increasing the avalanche breakdown diode term. --- Increasing the metal oxide varistors term. --- Increased thyristor surge arrester term. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee arrester. This standard is mainly drafted by. Xi'an Ceramic Institute, Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd., Xi'an Power Electronics graduate School. The main drafters of this standard. Cheng Wenyi, Jiang Rong Xing Wei Hongqi, Zhang Ning series, Wang Biyun, Li Jian. This standard was first published in 1989, this is the first revision. Electrotechnical terminology Surge arresters and low-voltage surge protector element

1 Scope

This standard specifies the arresters, voltage surge protector and special terms used functional components, mainly for the development of standards, preparation of technical Art documents, translated professional manuals, textbooks, books and the like.

2 general terms

2.1 Used to protect electrical equipment from high transient over-voltage hazards and limit the freewheeling time often limit wheeling An electric appliance amplitude. This term It contains installation run the appliance for any external gap necessary for normal function, regardless of whether a component as a whole. Note 1. The arresters are usually connected between grid wires and the ground, but sometimes the connection between electrical wires or winding side. Note 2. The lightning is sometimes also referred to as over-voltage protection, over-voltage limiter (surgedivider). 2.2 SPD For limiting transient over-voltage and surge current electrical discharge, which contains at least one non-linear element. Note. Surge protectors also known as surge protectors. 2.3 By the non-linear metal oxide varistor series and (or) connected in parallel or in series and in parallel without discharge gap arrester. Note. No MOA also sometimes referred to as metal oxide surge arresters (metal-oxidesurgearrester or MOA), gapless surge arresters. 2.4 A metal oxide varistor and a discharge gap in series and/or parallel connection of surge arresters. 2.5 Having one or more discharge gap and one or more non-linear resistors in series or parallel arrester. Note. There is a gap-type surge arresters are sometimes also referred to as gap arrester. 2.6 Silicon carbide non-linear resistors in series with the discharge gap arrester. Silicon carbide Varistor discharge gap with non-magnetic blow arrester series composed of ordinary valve arrester. Silicon carbide non-linear resistors in series with the discharge gap magnetic blow arrester composed of magnetic blow valve type arrester. 2.7 An arrester insulator flashover generally applicable to dangerous power lines in order to reduce the impact when lightning transients. Note. not usually used to protect the insulator against other transient shocks, such as the impact of the operation. If necessary, it can also be used to protect the outside of the line insulator any He Appliances.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 2900.12-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 2900.12-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 2900.12-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 2900.12-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 2900.12-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 2900.12-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.