GB/T 19862-2016 English PDFUS$559.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19862-2016: General requirements for monitoring equipment of power quality Status: Valid GB/T 19862: Historical versions
Basic dataStandard ID: GB/T 19862-2016 (GB/T19862-2016)Description (Translated English): General requirements for monitoring equipment of power quality Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F20 Classification of International Standard: 17.220.20 Word Count Estimation: 28,282 Date of Issue: 2005-07-29 Date of Implementation: 2017-03-01 Older Standard (superseded by this standard): GB/T 19862-2005 Regulation (derived from): National Standard Announcement 2016 No.14 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the general requirements for terms and definitions, classification and measurement of electrical energy quality monitoring equipment, technical requirements, test, inspection rules, marking, packaging, transportation and storage. This standard is applicable to fixed monitoring equipment and portable monitoring equipment for monitoring and measuring the power quality of AC power system. GB/T 19862-2016: General requirements for monitoring equipment of power quality---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.General requirements for monitoring equipment of power quality ICS 17.220.20 F20 National Standards of People's Republic of China Replace GB/T 19862-2005 General requirements for power quality monitoring equipment 2016-08-29 released 2017-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 Classification and measurement 4.1 Classification and classification 2 4.2 Measurement links 3 Technical requirements 3 Basic functional requirements 3 5.2 Measurement methods and data storage 5 5.3 Accuracy requirements 6 5.4 Electrical performance requirements 8 5.5 Climatic environmental conditions 5.6 Housing, mechanical properties 9 5.7 Electrical safety performance 10 5.8 Electromagnetic compatibility (EMC) 11 5.9 Mean time between failures 11 6 Test 11 6.1 Test conditions and procedures 11 6.2 Basic function test 12 6.3 Maximum permissible error 12 6.4 Electrical performance test 13 6.5 Climate protection test 14 6.6 Shell and mechanical properties test 14 6.7 Electrical safety performance test 15 6.8 Electromagnetic compatibility test 15 7 Inspection rules 16 7.1 Factory inspection 16 7.2 Type Test 16 7.3 Inspection items 16 8 Marking, packaging, transportation and storage 17 8.1 Product Mark 17 8.2 Packaging 17 8.3 Transport and storage 18 Appendix A (informative) Power Quality Data Model Specification Appendix B (informative) Power Quality Data Exchange File (PQDIF) Document Specification 23 Reference 25 ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 19862-2005 "General requirements for power quality monitoring equipment", compared with GB/T 19862-2005 The changes are as follows. - Removes generic power quality terms, including "voltage deviation" "frequency deviation" "(inter) harmonics" "three-phase unbalance" Change "" voltage sag "" temporary "" short interrupt "and so on; --- Added terms related to describing the performance of power quality monitoring equipment, including "influence volume range" and "average failure interval" --- Chapter 4 Title "Classification and composition" to "Classification and measurement links", increased by "according to the measurement method of measurement" classification section, The introduction of A-level, S-class, B-class concept; --- "5.1 basic functional requirements", an increase of monitoring equipment "communication protocol" requirements, the introduction of DL/T 860 protocol and PQDIF data Format, the principle of the requirements to Appendix A, Appendix B given, while increasing the "interface with the electronic transformer" requirements; --- increase the "5.2 measurement methods and data storage" content; --- "5.3 accuracy requirements", the introduction of "signal impact" concept, and according to A, S level gives the maximum allowable error requirements, given The transient power quality indicators of the measurement error requirements; the article also modified the.2005 version 2 three-phase voltage imbalance and Three - phase current imbalance calculation formula error; --- "5.5 climate and environmental conditions", the introduction of the "extreme environmental temperature" concept, on-line, portable two types of equipment, respectively, to the Out, including storage and transportation, indoor and outdoor operation of climate and environmental requirements; - Chapter 6 of the test part, an increase in the transient power quality error measurement method; - Chapter 8 adds the "Product Code" content. This standard is proposed by the National Voltage and Current Rating and Frequency Standardization Technical Committee (SAC/TC1). The main drafting unit of this standard. Xi'an Bo Yu Electric Co., Ltd., State Grid Shanxi Electric Power Company Electric Power Research Institute, the machine productivity Shanghai Electric Power Company Electric Power Research Institute, State Grid, Jiangsu Province, Power Company Electric Power Research Institute, Shenzhen Zhongdian Electric Power Technology Co., Ltd., Hefei Jinnao Ren Technology Development Co., Ltd., China Railway Fourth Survey and Design Institute, State Grid Beijing Electric Power Company Electric Power Research Institute, Henan Institute of Metrology, Shenzhen Power Supply Bureau Co., Ltd., State Grid Smart Grid Research Institute. The main drafters of this standard. Liu Juncheng, Wang Jinhao, Liu Jing, Pan Aiqiang, Li Qionglin, Yuan Xiaodong, Wang Xin, Xu Pei, Huang Dongping, Du Chenhong, Chen Qingping, Shi Shuaibin, Lin Haixue. General requirements for power quality monitoring equipment1 ScopeThis standard specifies the terms and definitions of power quality monitoring equipment, classification and measurement links, technical requirements, testing, inspection rules, signs, Packaging, transportation and storage and other general requirements. This standard is applicable to fixed monitoring equipment and portable monitoring equipment for monitoring and measuring the power quality of AC power system.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 191 packaging and storage icon GB/T 2423.1-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test A. Low temperature GB/T 2423.2-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test B. High temperature GB/T 2423.4 Basic environmental testing for electric and electronic products - Part 2. Test methods - Test Db alternating hot and humid (12 h 12h cycle) GB/T 2423.5 Environmental testing for electric and electronic products - Part 2. Test methods - Test Ea and Guidance. Impact GB/T 2423.10 Environmental testing for electric and electronic products - Part 2. Test methods - Test Fc. Vibration (sinusoidal) GB 4208-2008 enclosure protection class (IP code) Data element and exchange format - Information exchange date and time representation ISO /TS Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.2-2006 GB/T 17626.3-2006 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic radiation immunity test GB/T 17626.4-2008 Electromagnetic compatibility test and measurement techniques Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test Electromagnetic compatibility (EMC) - Testing and measurement techniques - Test method for power quality GB/T 17626.30-2012 Electromagnetic compatibility environment - Compatibility level of low frequency conducted harassment Transformers - Part 7. Electronic voltage transformers GB/T Transformers - Part 8. Electronic current transformers GB/T Power quality voltage sags and short interruptions GB/T 30137-2013 DL/T 860 (all parts) substation communication networks and systems3 terms and definitionsThe following terms and definitions apply to this document. 3.1 Power quality monitoring equipment monitoringequipmentofpowerquality Through the introduction of the voltage and current signal analysis and processing, to achieve the power quality indicators to monitor the special device. 3.2 Transient overvoltage A number of milliseconds or less, usually with a strong damping of the oscillation or non-oscillation of an over-voltage. It can be superimposed on a temporary overcharge Pressed on. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19862-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 19862-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 19862-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19862-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 19862-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19862-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |