GB/T 10283-2016 English PDFUS$219.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10283-2016: Forestry machinery -- Portable pneumatic fire extinguisher -- Measurement of vibration Status: Valid GB/T 10283: Historical versions
Basic dataStandard ID: GB/T 10283-2016 (GB/T10283-2016)Description (Translated English): Forestry machinery -- Portable pneumatic fire extinguisher -- Measurement of vibration Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C84 Classification of International Standard: 65.060.80; 13.160 Word Count Estimation: 11,131 Date of Issue: 2016-02-24 Date of Implementation: 2016-09-01 Older Standard (superseded by this standard): GB/T 10283-2008 Quoted Standard: GB/T 14790.2-2014; GB/T 20485.1; GB/T 20485.11; GB/T 20485.12; GB/T 20485.13; GB/T 20485.15; GB/T 20485.21; GB/T 20485.22; GB/T 20485.31; GB/T 20485.41; GB/T 23716 Regulation (derived from): National Standard Announcement No Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 10283-2016: Forestry machinery -- Portable pneumatic fire extinguisher -- Measurement of vibration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Forestry machinery - Portable pneumatic fire extinguisher - Measurement of vibration ICS 65.060.80 C84 National Standards of People's Republic of China Replacing GB/T 10283-2008 Forestry machinery - Portable pneumatic fire extinguisher Vibration Measurement Issued on. 2016-02-24 2016-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 10283-2008 "Determination forestry machinery - Portable pneumatic fire extinguisher handle vibration," compared with the GB/T 10283-2008 main technical changes are as follows. --- Changing the name of the standard, the "determination of forestry machinery - Portable pneumatic fire extinguisher handle vibration" was changed to "measurement forestry machinery - Portable pneumatic fire extinguisher vibration"; --- Modify the scope of the standard; --- Modify the "normative references"; --- To modify the tachometer accuracy requirements (see 43, 2008 edition 4.5.); --- Modify the calibration requirements Removed GB/T 13823 references (see 53, 2008 edition 4.4.); --- Modify the measurement conditions, the measurement conditions from the "full load" to "rated speed" (see 54, 2008 edition 5.3.); --- Modified accelerometer installation requirements (see 551, 5611, 5621, 2008, version 4.3...); --- Increased knapsack extinguisher back pad at the contents of vibration measurements (see 5.6.2); --- Modify the validity of the measurement results of the coefficient of variation Cv requirements and increases the measurement error checking requirements (see 62, Chapter 7, 2008 edition.); --- Remove the "handlebar vibration measurement arithmetic mean" recording table (Chapter 8 of the 2008 edition); --- Added "and indicated value of the vibration test" (see Chapter 8). This standard was proposed by the State Forestry Administration. This standard by the National Forestry Machinery Standardization Technical Committee (SAC/TC61) centralized. This standard is drafted by. Taizhou Yulin Power Machinery Company Limited. It participated in the drafting of this standard. Harbin Forestry Machinery Research Institute of the State Forestry Administration, Yongkang Xing Tiger Power Machinery Co., Ltd. Shandong Huasheng Zhongtian Machinery Group Co., Ltd., National portable forestry machinery Quality Supervision and Inspection Center, Husqvarna Almighty (Changzhou) Machinery Co., Ltd., Jiangsu Linhai power Machinery Group company. The main drafters of this standard. Sheng Ping, Yang Xuefeng, Shangnian Rong, Liu Xiangfeng, Wang Zhendong, Ma Jian, Yuan Xiaochun, Li Pai. This standard replaces the standards previously issued as follows. --- GB/T 10283-1988, GB/T 10283-1999, GB/T 10283-2008. Forestry machinery - Portable pneumatic fire extinguisher Vibration Measurement1 ScopeThis standard specifies the gasoline engine-powered portable pneumatic extinguishers (hereinafter referred to as fire extinguishers) Determination of vibration. This standard applies to the determination forestry machinery - Portable pneumatic fire extinguisher vibration measurement, but also for forestry machinery - Portable water extinguisher wind vibrations.2 Normative referencesThe following documents for the application of this document is essential. For cited documents with dates, only the dated edition applies to this document. For undated references, the latest edition (including any amendments) applies to this document. GB/T 14790.2-2014 Mechanical vibration of human exposure to hand-transmitted vibration measurement and evaluation - Part 2. A Practical Guide to Workplace measurements GB/T 20485 (all parts), vibration and shock sensor calibration method GB/T 23716 people vibration response of measuring instruments3 measurement parameters3.1 Hand-held fire extinguishers Weighted acceleration ahwx two handles on three mutually perpendicular directions, ahwy, ahwz. Two handles on each of the total value of the acceleration ahv (ahv is weighted acceleration ahwx, ahwy, ahwz square and the square root, the same below). 3.2 knapsack extinguisher Handles and back pad weighting each point three mutually perpendicular directions acceleration ahwx, ahwy, ahwz. Handles and their total acceleration values ahv back pad.4 measuring instruments4.1 Requirements Vibration test systems shall comply with GB/T 23716 of. 4.2 Accelerometer Determination of the total mass of the accelerometer a position (including bearings, cable not included) should not exceed 25g, see GB/T 14790.2-2014 in 6.1.5. Note. The accelerometer is a sensor vibration into an electrical signal. Accelerometer may be three-dimensional coordinates, the x, y, z-coordinate direction is measured simultaneously. 4.3 Tachometer Tachometer accuracy shall not exceed ± 1.0%. During the test, tachometer and installation should not affect the operation of the machine. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10283-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 10283-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 10283-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10283-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 10283-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10283-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |