US$414.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 7000.214-2015: Luminaires -- Part 2-14: Particular requirements -- Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
Status: Valid
| Standard ID | USD | BUY PDF | Lead-Days | Standard Title (Description) | Status |
| GB 7000.214-2015 | 414 |
Add to Cart
|
4 days
|
Luminaires -- Part 2-14: Particular requirements -- Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
| Valid |
Basic data
Standard ID: GB 7000.214-2015 (GB7000.214-2015)
Description (Translated English): Luminaires -- Part 2-14: Particular requirements -- Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
Sector / Industry: National Standard
Classification of Chinese Standard: K72
Classification of International Standard: 29.140.40
Word Count Estimation: 21,266
Date of Issue: 2015-06-02
Date of Implementation: 2016-01-01
Quoted Standard: GB 19149-2003; GB 19510.11-2004; IEC 60417; IEC 60529
Adopted Standard: IEC 60598-2-14-2009, IDT
Regulation (derived from): National Standard Announcement 2015 No.19
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard applies to the supply voltage does not exceed 1000V, operates in more than 1000V but not exceeding 10000V no-load rated output voltage, cold cathode tubular discharge lamps and similar lighting equipment, mainly used for indoor or outdoor general lighting. This section applies to a light emitting discharge tube and the power supply unit of fixed or movable luminaires, by the transformer, converter or inverter provides a high voltage, mains voltage or extra-low voltage (ELV). This section does not apply to the work of the light-emitting discharge standard GB 7000 standard relates to the specific product rated voltage not exceeding 1000V (preheat cathode) lamps, wiring rules and application area, on-site assembly, an electrical system as a luminescent discharge lamps. This part of GB 7000.1 cited relevant sections together.
GB 7000.214-2015: Luminaires -- Part 2-14: Particular requirements -- Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Luminaires.Part 2-14. Particular requirements.Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
ICS 29.140.40
K72
National Standards of People's Republic of China
Luminaires - Part 2-14. Specific requirements
Cold cathode discharge lamps
Lamps (neon) and similar devices
Luminaires-Part 2-14. Particularrequirements-Luminairesforcold
cathodetubulardischargelamps (neontubes) andsimilarequipment
(IEC 60598-2-14.2009, IDT)
Published 2015-06-02
2016-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative References 1
3 1 General test requirements
Terms and definitions 4 1
5 Category 3
6 3 mark
7 Structure 3
External and internal wiring 8 6
9 Ground provisions 7
7 10 Protection against electric shock
11 dust, water and solid objects 7
12 Insulation resistance and electric strength 7
13 creepage distance and clearance 7
Thermal test and durability test 14 9
15 heat, fire resistance to tracking and 9
16 screw terminal 10
Screwless terminals 17 and electrical connections 10
Annex A (normative) standards or equivalents predetermined high voltage cable list file 14
Reference 16
Table 1 in Appendix A corresponds to the type of cable 6
Table creepage distances and clearances general lighting circuit 2 operating at a nominal frequency power source 8
Table 3 creepage distances and clearances frequencies exceeds 1kHz ordinary lamp operating circuit 8
Table 4 Non ordinary lamp circuit at a rated power frequency creepage distance and clearance 9
Table 5 creepage distance and clearance lamp circuit 9 in the non-common frequencies exceeds 1kHz work
Table A.1 predetermined high voltage cable lists the relevant file 14 or equivalent standards
FIG cold cathode lamps 1 inside the box layout example of Figure 10
FIG 2 through FIG exemplary electrode housing panel 11 signboard
3 through FIG electrode layout example of flat metal plate 12 of the lamp mounting surface
Layout Example 4 FIG creepage distance and clearance 13
Figure 5 Effect of bushing clearances and creepage distances of 13
Foreword
All technical contents of this section is mandatory.
This part is a part of the national standard GB 7000 lamps 7000 part of the existing 23 GB , the publication date of this section, has been published
GB 7000 standard score of the following.
--- lamps - Part 1. General requirements and tests (GB 7000.1-2007);
--- lamps Part 2-22. Particular requirements for emergency lighting (GB 7000.2-2008);
--- lamps Part 2-10. Particular requirements for children luminaries (GB 7000.4-2007);
--- lamps - Part 2-6. Particular requirements with a built-in transformer or converter tungsten lamp (GB 7000.6-2008);
--- Floodlights safety requirements (GB 7000.7-2005);
--- lamps Part 2-20. Particular requirements for light string (GB 7000.9-2008);
--- safety requirements limit the surface temperature of the lamp (GB 7000.17-2003);
--- tungsten with extra low voltage lighting system security requirements (GB 7000.18-2003);
--- photo and film luminaires (non-professional use) safety requirements (GB 7000.19-2005);
--- lamps - Part 2-1. Particular requirements for fixed general purpose luminaires (GB 7000.201-2008);
--- Luminaires - Part 2-2. Particular requirements for Recessed Lighting (GB 7000.202-2008);
--- lamps - Part 2-3. Particular requirements for road and street lighting (GB 7000.203-2013);
--- lamps - Part 2-4. Particular requirements for portable general purpose luminaires (GB 7000.204-2008);
--- lamps - Part 2-7. Particular requirements for garden use luminaries (GB 7000.207-2008);
--- lamps - Part 2-8. Particular requirements for portable lamp (GB 7000.208-2008);
--- lamps - Part 2-11. Particular requirements for the aquarium lamp (GB 7000.211-2008);
--- lamps Part 2-12. Particular requirements nightlight power outlet mounted (GB 7000.212-2008);
--- Luminaires - Part 2-13. Particular requirements for ground recessed light fixtures (GB 7000.213-2008);
--- lamps - Part 2-14. Particular requirements for the use of cold cathode discharge lamps (neon) lamps and the like
(GB 7000.214-2014);
--- Luminaires - Part 2-17. Particular requirements for stage lighting, television, film and photographic studios (outdoor and indoor) lighting
(GB 7000.217-2008);
--- lamps Part 2-18. Particular requirements for swimming pools and similar lamp (GB 7000.218-2008);
--- lamps - Part 2-19. Particular requirements for ventilated luminaire (GB 7000.219-2008);
--- Luminaires - Part 2-25. Particular requirements for the building of hospitals and rehabilitation clinics lamp (GB 7000.225-2008).
This is Part 2-14 GB 7000's.
This section drafted in accordance with the rules GB/T 1.1-2009 given.
This section uses the translation method is equivalent to using IEC 60598-2-14.2009 "lamps - Part 2-14. Particular requirements for the use of cold cathode tubes
Discharge lamp lighting "(neon) and similar devices.
Consistency correspondence relationship with international documents in this section of our normative references the following documents.
--- GB 4208-2008 level of protection provided by enclosures (IP Code) (IEC 60529.2001, IDT)
--- GB/T 5465.1-2009 Graphical symbols electrical equipment Part 1. Overview and classification (IEC 60417DB.2007,
MOD)
--- GB/T 5465.2-2008 electrical equipment Graphical symbols Part 2. Graphical symbols (IEC 60417DB.2007, IDT)
This section was proposed by China Light Industry Federation.
This part of the Technical Committee (SAC/TC224/SC2) under the jurisdiction of the lamp lighting the National Standardization Technical Committee points.
This section was drafted. the era of Shanghai Lighting Appliance Testing Co., the National Lighting Fitting Quality Supervision and Inspection Center, the National Electric Light Source
Quality Supervision and Inspection Center (Shanghai), Hangzhou Hongyan Electric Co., Ltd., Dongguan City, the National Lighting Fitting Quality Supervision and Inspection Center (Zhongshan), Guangdong Province
Quality Supervision and Testing Center, Changzhou City, product quality supervision and inspection.
The main drafters of this section. Shi Xiaohong, Yu Road again, Liu Li Er, Yang Guoxian, Yang Yue, Lu Shiming, Zhao Xu, Original Starting Peng Zhenjian, Liang Lee,
Shi Chaoyang, Li Jun.
Luminaires - Part 2-14. Specific requirements
Cold cathode discharge lamps
Lamps (neon) and similar devices
1 Scope
GB 7000. This part does not exceed the power supply voltage applied to 1000V, 1000V greater than but not more than the load rated 10000V
Work in the output voltage, the cold cathode lamp tubular discharge lamps and similar devices, mainly for indoor or outdoor general lighting.
Note. In Japan, the output voltage of 15000V is applicable.
This section applies to fixed or luminaries including a light emitting discharge tube and the power supply section, by the transformer, converter or inverter supplies
High voltage, mains voltage or extra-low voltage (ELV).
This does not apply to a light emitting discharge working standard GB 7000 relates to the specific product standards do not exceed the rated voltage of 1000V
(Preheated cathode) lamps, and the application area wiring rules, assembled on site, as a light-emitting discharge lamps electrical system.
This part used with relevant sections GB 7000.1 reference.
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper
Pieces. For undated references, the latest edition (including any amendments) applies to this document.
GB 19149-2003 load output voltage exceeding 1000V tubular discharge lamps having a transformer (neon transformer) and the general requirements
Safety Requirements (eqvIEC 61050.1991)
Part 11 GB 19510.11-2004 lamp control apparatus. a high frequency cold start tubular discharge lamps (neon) electronic inverter
And special requirements of the drive (IEC 61347-2-10.2000, IDT)
IEC 60417 devices with graphical symbols (Graphicalsymbolsforuseonequipment)
IEC 60529 shell protection (IP code) [Degreesofprotectionprovidedbyenclosures (IPCode)]
3 General test requirements
7000.1 provisions of Chapter 0 Application GB .
Note. GB 7000.1 Chapter 0 covering the complete product, routine tests can be carried out in accordance with Appendix Q 7000.1 GB of.
Terms and definitions 4
Application of GB 7000.1 Chapter 1 and the following terms and definitions.
4.1
Emitting discharge luminous-dischargetube
A sealing tube made of a translucent material, or other container or apparatus, since the current through the internal gas or vapor to emit light.
Note. with or without a fluorescent tube may be coated.
4.2
Load rated output voltage of the no-loadratedoutputvoltage
2.8 GB 19149-2003 maximum rated output winding transformer voltage between terminals, or GB 19510.11-2004
Between the maximum rated voltage of 3.2 inverter or drive terminals.
4.3
Insulating sleeve insulatingsleeve
Placed in the high-pressure connection point or the cable jacket at the end of the insulated pipe electrode exposed.
4.4
Earth leakage protection device earthleakageprotectivedevice
When a short circuit occurs between the correlation between the output member and the ground circuit or a plurality of the control means of the power cut-off means output.
NOTE. means may be two portions, a sensor and a circuit breaker (see 7.3), or may be combined in one element (internal or external control means
unit).
4.5
Open-circuit protection means open-circuitprotectivedevice
When the secondary high voltage generator circuit interrupting power cut-off from the one or more output control means.
NOTE. means may be two portions, a sensor and a circuit breaker (see 7.4), or may be combined in a single element.
4.6
Open circuit conditions open-circuitcondition
The output circuit is disconnected or lamp failure, causes the load current or power supplied to the lamp current control device to the respective circuits of the closed-circuit falling
Limit.
4.7
Closed circuit current limit shut-downcurrentlimit
Open the load current of the transformer when the secondary protective device operates.
Note. Although the current limit is based on closed-circuit current flowing through a predetermined output circuit, the device manufacturer may indirect measurement method. These methods may
A current transformer comprising a primary winding coupled to such measurement, the measuring circuit or the power factor change.
4.8
Sensor sensor
Member protection device for a secondary winding found ground fault and (or) open-circuit condition and provides a signal that the protection means
jobs.
4.9
Protection switch protectiveswitch
Member protection means for disconnecting the connection between the main power supply and control apparatus, or off the output power.
Electronic signals provided by the sensors associated to make it work.
4.10
Automatic chopper flasher
One or more output circuits on and off the continuous automatic conversion means.
Note. the order of various conversion can be suitably arranged to provide an output circuit and other dynamic impression of the effect of exercise.
4.11
Discharge lamp emitting luminous-dischargetubeluminaire
The load voltage is higher than the composition but not exceeding 1000V 10000V light source lamp in the plant (pre-assembled product).
4.12
Portable cold cathode lamps portablecoldcathodeluminaire
Is a cold cathode lamp design, can be easily moved during normal operation, and to provide a non-detachable flexible cable, and a combination of the pressure swing
, A converter or inverter.
Note. It is designed to be installed by the user and connected to the main power supply.
4.13
Box-type cold cathode lamps boxedcoldcathodeluminaire
Lamps with a translucent plate is a cold cathode lamp design, the plate may be printed with text.
Category 5
This section covers the lamp should be classified in accordance with GB 7000.1 Chapter 2. Moreover, it should meet the following requirements.
Protection against electric shock by classification. class Ⅰ or Class Ⅱ only.
NOTE. Portable cold cathode lamps classified as suitable for surface mounting on ordinary combustible materials.
6 marks
Application GB 7000.1 Chapter 3 of the following provisions.
6.1 in accordance with IEC 60417-5036 (2002-10) required "Warning. electric shock hazard" warning marker should be placed close to the lamp, glow discharge
Tube, or a high-pressure position of the housing means controlled
Note 1. In order to see the symbol After installing the light emitting discharge tube, it is necessary to increase the size of the symbol or place different points.
Note 2. In the United States, also requires the following warning. "Warning. electric shock Hazardous voltage will cause electric shock, burns or death", "Warning. Do not fire danger.
The output circuit is connected to any ground metal. "
6.2 In order to facilitate maintenance of the light-emitting discharge lamps, the manufacturer should be given to the user from the product 6.2.1 - 6.2.5 and/or the specification
information.
6.2.1 The simplified circuit diagram can be identified and discharge light emission control means.
6.2.2 Linear maximum lamp current, the type of mercury mixed gas or pure neon or other, and a light emitting electrode-free discharge length ---
length.
6.2.3 No power lamp member, the no-load output voltage of the lamp control device, short-circuit current.
6.2.4 applicable, provides additional information in GB 19149-2003 7.2 days) and e).
6.2.5 provide open-circuit protection for transformer lighting device, the current limit information is closed.
Suitably 6.3 or within arm's reach of information region (see 7.2) inappropriate installation.
7 Structure
Application of GB 7000.1 Chapter 4 the following provisions.
All contact with high light emission of the discharge tube connector 7.1 protective insulating sleeve made of an insulating material suitable to use.
Instead of following the requirements of 4.9.2 in GB 7000.1.
The bushing should be one of the following manufactured.
a) The minimum thickness of 1mm glass; or
b) silicone rubber, approved by the supplier is not less than the breakdown voltage of the control device of the supply circuit of the load rated output voltage to ground
2 times, and 1mm wall thickness of not less than the operating temperature of not less than 180 [deg.] C; or
c) insulating materials, resistance to UV radiation, oxidation resistance at least equivalent, and b) a predetermined heat resistance.
Note. All experiments the suitability of the silicone rubber by the test section.
Compliance is checked by inspection.
7.2 Preparation mounted within arm's reach of the lighting area, if possible contact with live parts of the secondary circuit after discharge damage, should full
4.5 foot open-circuit protection requirements.
Compliance is checked by inspection.
7.3 pairs earth leakage protection
A high voltage circuit other than an inverter drive power Class A or Class 7.3.1 Ⅰ lamps, should leakage to ground in GB 19510.11-2004
Sensing means for providing electrical protection. A high voltage circuit supplied from a transformer class Ⅰ lamps, should be protected in accordance with the requirements of 7.3.2 and 7.3.3.
If the earth leakage protection device operation result in, the high pressure should be maintained until the circuit is broken. If the switch is still closed after the leakage, the protective
Means shall operate in accordance with 7.3.3 and 7.3.2.
An induction 7.3.4 ensure performance of earth-leakage device.
7.3.2 When the high voltage circuit between the ground and the accidental contact device off or disconnect the lamp power output. If a supply voltage
The single-pole switch, the switch should be connected with the power line.
7.3.3 Use of a suitable sensor for detecting the fault condition is connected to the output circuit (earth leakage), the sensor should be turned off or the power supply circuit
The cutting operation by means of the output power.
Note 1. The sensor device and a contactor shall components.
Note 2. The earth leakage protection device to protect the plurality of lighting circuits.
7.3.4 earth leakage protection device shall meet the following requirements.
--- if the protective device and a sensor (or) disconnecting the output power is not placed within the control unit housing, should be at -25 ℃ ~
The normal operating temperature in the range of 65 deg.] C. If the device is operated, it should be noted in the specification at different temperatures;
--- if such components should be part of the sensor, and (or) the switching contacts or the output power of the device mounted in the control unit housing,
Work in the temperature range provided by the housing. During GB 7000.1 12.4 and 12.5 test sensors, and (or) protection
This part of the maximum ambient temperature should guard means exceeds the allowable maximum temperature;
--- means that the operating current should not exceed the nominal rated load current of the secondary of the transformer to be protected, and no more than 25mA;
Note 1. In the effective current through the sensor to the process flow discharged by the discharge circuit providing this impedance and the output characteristic is determined not flow through the protective device
Current.
--- means off the output time should not exceed 200ms;
--- test earth leakage current sensor component should not exceed the terminal voltage of 50V.
Earth leakage protection device shall be tested according to the instructions of the manufacturer of such devices, the test shall ensure normal operation member.
Note 2. earth leakage protection device with the relevant standards should be consistent with regional norms.
Note 3. In the United States and Canada, if the rating is less than 15mA, the operating current rating equal to the control device, and can not exceed 15mA. In-ground leakage
When the power exceeds 15mA, the output of the high-pressure cutting apparatus for longer than 500ms.
7.3.5 Disconnect the power if the earth leakage protection device designed to occur, the device should be associated mechanical contacts. Semiconductor (SCR, bis
) Switching means is not allowed to SCR.
7.3.6 If the automatic circuit includes a chopper, and all reset circuit protection switch should be installed in the automatic intermittent electrical apparatus
Source side.
NOTE. will restart and again until the trip during a fault condition if the protection device and the load on the side of the automatic reset circuit interrupter device, the protection switch.
7.3.7 If the circuit interrupter apparatus with automatic cut off the output and the load device is integrated in the housing of the control device, then.
--- Circuit protection switch should be connected to the power supply side chopper of the automatic, sensor-integrated and should enable the protection switch action
Make; or
--- provide the means to prevent resetting of the protection device when power is turned on again after each automatic chopper turned off.
7.3.8 sensor operation and protection devices should be compatible.
7.3.9 7.3.1 7.3.8 Co......
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB 7000.214-2015_English be delivered?
Answer: Upon your order, we will start to translate GB 7000.214-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB 7000.214-2015_English with my colleagues?
Answer: Yes. The purchased PDF of GB 7000.214-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.