GB 7000.207-2008: Luminaires -- Part 2-7: Particular requirements: Portable luminaries for garden use
Status: Obsolete
| Standard ID | USD | BUY PDF | Lead-Days | Standard Title (Description) | Status |
| GB 7000.207-2008 | 319 |
Add to Cart
|
3 days
|
Luminaires -- Part 2-7: Particular requirements: Portable luminaries for garden use
| Obsolete |
Basic data
Standard ID: GB 7000.207-2008 (GB7000.207-2008)
Description (Translated English): Luminaires -- Part 2-7: Particular requirements: Portable luminaries for garden use
Sector / Industry: National Standard
Classification of Chinese Standard: K72
Classification of International Standard: 29.140.40
Word Count Estimation: 8,834
Date of Issue: 2008-12-30
Date of Implementation: 2010-04-01
Older Standard (superseded by this standard): GB 7000.3-1996
Regulation (derived from): Announcement of Newly Approved National Standards No. 27 of 2008 (total 140)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard relates to garden spaces with a portable lamps as well as the base for the flower bed portable luminaires safety requirements, these lamps use supply voltage not exceeding 250V electric light source, together with the part of the GB 7000. 1 together with the relevant sections.
GB 7000.207-2008: Luminaires -- Part 2-7: Particular requirements: Portable luminaries for garden use
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Luminaires.Part 2-7. Particular requirements. Portable luminaries for garden use
ICS 29.140.40
K72
National Standards of People's Republic of China
GB 7000.207-2008/IEC 60598-2-7. 1982
Replacing GB 7000.3-1996
Luminaires - Part 2-7. Particular requirements
Garden use luminaries
(IEC 60598-2-7. 1982, IDT)
Published 2008-12-30
2010-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Preface Ⅰ
1 Scope 1
2 1 General test requirements
Terms and definitions 1 3
4 lamps Category 1
Flag 1 5
6 Structure 1
7 creepage distances and clearances 2
8 Ground 2 provisions
Terminal 2 9
External 10 and internal wiring 2
11 Protection against electric shock 2
Thermal test and durability test 12 2
13 dust and water 2
14 Insulation resistance and electric strength 3
15 heat, and resistance to tracking refractory 3
GB 7000.207-2008/IEC 60598-2-7. 1982
Foreword
All technical contents of this section is mandatory.
GB 7000 series of standards existing section 22, the publication date of this section, published GB 7000 series of standards are as follows.
GB 7000.1-2007 lamps - Part 1. General Requirements and Test
GB 7000.2-2008 lamps - Part 2-22. Particular requirements for emergency lighting
GB 7000.4-2007 lamps Part 2-10. Particular requirements for children luminaries
GB 7000.5-2005 road and street lighting safety requirements
GB 7000.6-2008 lamps - Part 2-6. Particular requirements with a built-in transformer or converter tungsten lamp
GB 7000.7-2005 safety requirements Floodlights
GB 7000.9-2008 lamps Part 2-20. Particular requirements for light string
GB 7000.17-2003 safety requirements limit the surface temperature of the lamp
GB 7000.18-2003 filament lamps extra low voltage lighting system security requirements
GB 7000.19-2005 photo and film (non-professional use) Safety requirements for lighting
GB 7000.201-2008 lamps - Part 2-1. Particular requirements for fixed general purpose luminaires
GB 7000.202-2008 Luminaires - Part 2-2. Particular requirements Recessed Lighting
GB 7000.204-2008 lamps - Part 2-4. Particular requirements for portable general purpose luminaires
GB 7000.207-2008 lamps - Part 2-7. Particular requirements for garden use luminaries
7000.208-2008 lamps - Part 2-8 GB . Particular requirements handlamps
GB 7000.211-2008 lamps Part 2-11. Particular requirements for the aquarium lamp
GB 7000.212-2008 lamps - Part 2-12. Particular requirements for the power outlet mounted nightlight
GB 7000.213-2008 Luminaires - Part 2-13. Particular requirements for ground recessed light fixtures
GB 7000.217-2008 lamps Part 2-17. Particular requirements for stage lighting, television, film and photographic studios (indoor and outdoor)
Lighting
GB 7000.218-2008 Luminaires - Part 2-18. Particular requirements for swimming pools and similar lighting
GB 7000.219-2008 lamps - Part 2-19. Particular requirements for ventilated luminaires
GB 7000.225-2008 Luminaires - Part 2-25. Particular requirements. the building of hospitals and rehabilitation clinics lamp
This section 7000 "lamps" Part 2-7 GB .
This section should be used with GB 7000.1.
This section is equivalent to using IEC 60598-2-7. 1982 "lamps - Part 2-7. Particular requirements for garden use luminaries" [repair comprising
Order 1 (1987), Revision 2 (1994)].
For ease of use, this section following editorial changes made.
--- on the application of a light source into a line with IEC 60598-1, i.e., the original tungsten filament, tubular fluorescent and other gas discharge lamps change
An electrical source (Chapter 1);
--- The IEC 60083 replaced by our standards GB 1002 (6.6);
--- on power outlet mounted on the lamp type Ⅰ, the "power source mounted on the lamp type Ⅰ predetermined interpolation IEC 60598-2-7
Block only allows connections with class Ⅰ and Ⅱ type lamps "to" outlet mounted on the lamp type Ⅰ, only lamps even with class Ⅰ
Then "(6.6).
This partial replacement GB 7000.3-1996 "Safety requirements for portable luminaires for garden use."
This portion of the main technical difference GB 7000.3-1996 follows.
GB 7000.207-2008/IEC 60598-2-7. 1982
--- marking requirement increases, i.e., the maximum power should be marked (5.1) derived from the calculated maximum rated current of the power supply line on the luminaire;
--- on the connection between the power supply and the respective other plug socket fixture, a predetermined dust and water level should reach at least
IP53 (6.6);
--- deleted the original standard flat plug on the restriction of the use of 10.3;
--- This part of GB 7000.3 Standard to GB 7000.207.
This section was proposed by China Light Industry Federation.
This part of the lamp lighting of the National Standardization Technical Committee of Standardization Technical Committee.
This part mainly drafted by. National Lighting Fitting Quality Supervision and Inspection Center, the National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Shanghai time
Instead Lighting Appliance Testing Co., Zhejiang Sunshine Group Co., Ltd.
The main drafters of this section. Ling Li, Shi Xiaohong, Chen Chao, the officer Yong, Chen Jiong, Wang Yin, Lu Peiguang, Chen Weiguo, Zhu war.
This section replaces the following previous editions.
--- GB 7000.3-1996
GB 7000.207-2008/IEC 60598-2-7. 1982
Luminaires - Part 2-7. Particular requirements
Garden use luminaries
Range 1
GB This part fixture 7000 for a predetermined place such as a garden with the transportable base and for luminaries such as flower beds
Safety requirements, these lamps does not exceed the power supply voltage of 250V electric source, together with the relevant sections of this section along GB 7000.1
use.
2 General test requirements
Application of GB 7000.1 Chapter 0, GB 7000.1-2007 respective chapters of the tests listed in this section should be sequentially performed.
3 Terms and Definitions
GB 7000.1 application is defined in Chapter 1.
Lighting Category 4
GB claim lamps shall 7000.1 Chapter 2 4.1-4.2 classification.
4.1 The classification type of protection against electric shock, garden use should be based luminaries Ⅰ, Ⅱ Ⅲ class or classes.
The dust and water 4.2 grade classification, luminaries for garden use to prevent leaching should, splash-proof, or watertight type blowout preventer.
5 Mark
7000.1 provisions of Chapter 3 of Application GB .
5.1 mounted in the vicinity of the outlet fixture to be marked on the maximum power of the power supply line derived from the calculated maximum current rating.
6 structure
Application of 6.1 to 6.7 or less in 7000.1 Chapter 4 GB .
6.1 and the cord clip carrier should be made of an insulating material, or when they are accessible or accessible with the metal member when in contact
It should provide a fixed insulating lining.
Compliance is checked by inspection.
6.2 luminaries for garden use should be adequate degree of stability.
Compliance by the following test method, i.e. the most unfavorable position of normal use the lamp is placed on a flat angle, and the horizontal plane of plate
15 °, the plate surface of the lamp should not slip. Lighting should not be overturned.
Using clamps, pins or the like clamping fixture, you do not have to withstand such a test.
6.3 should be provided in a manner so that any lamps may be normal position of use, which is connected to the power supply flexible cable or cord will not be damaged
Bad. Flexible cables or protective position of the inlet should prevent a detrimental effect mud splashed from the ground.
Compliance by inspection and by installing test (if required) to test.
NOTE. For example, the available ground pin driven into the fender, the distance from the ground to the cable entry of at least 10cm ways of meeting this requirement.
6.4 GB 7000.1 4.6 apply to this section.
6.5 Cable inlet garden luminaries to be no more than two.
Compliance is checked by inspection.
GB 7000.207-2008/IEC 60598-2-7. 1982
6.6 the connection between the other lamp socket and a corresponding plug of the power supply, water and dust which should meet IP53 or higher level.
Lamps mounted on the class Ⅱ outlet should be non-subject, it may only be connected with such other classes Ⅱ lamp socket.
Note. The purpose of this section is not allowed using the device class Ⅱ modular plug is connected to the lamp, since when the lamp is connected to the class Ⅰ Ⅱ type lamp socket by
When the ground connection will fail.
Mounted on the lamp type Ⅰ outlet, connected only class Ⅰ lamps, and meet the following criteria.
GB 1002 single-phase household and similar purposes plug socket type, basic parameters and dimensions
IEC 60906 household and similar purposes IEC system plug socket
Note. My use of plug and socket should meet the requirements of GB 1002.
Compliance is checked by inspection.
It marks the socket and the plug material should be resistant to 6.7 from.
Compliance is defined by the 13.4 GB 7000.1 test test.
7 creepage and clearance distances
Application of GB 7000.1 Chapter 11.
8 grounding provisions
Application of GB 7000.1 Chapter 7.
Terminal 9
Application GB 7000.1 Chapters 14 and 15.
External and internal wiring 10
10.1 10.2 7000.1 ~ claims Chapter 5 following applications GB .
10.1 is not properly connected to provide flexible cable or cord and plug luminaries for garden use, should be flexible cable or cord is provided terminals, the cord
Inlet and holder.
NOTE. From wiring rules may need Ⅱ garden use luminaries with a non-detachable flexible cable or cord and plug.
Compliance by inspection and by installing test (if required) to test.
10.2 GB 7000.1 Chapter 5 5.2.2 is amended as follows.
Garden use of luminaries, non-detachable flexible cable or cord to be not less than 60245IEC 53 (GB/T 5013 "rated voltage
450/750V rubber insulated cables and a predetermined "standard series) requirements, but there should be neoprene or a similar synthetic material
The outer layer.
Compliance is checked by inspection.
11 Protection against electric shock
Application of GB 7000.1 Chapter 8.
Thermal test and durability test 12
Application of GB 7000.1 Chapter 12 and the following requirements.
IP classification number is greater than when the lamp is IP20, GB 7000.1 9.2 specified in this section should Chapter 13 after the test sample and 9.3
Before the test, carried out in GB 7000.1 12.4 -12.7 relevant tests.
13 dust-proof and waterproof
Application of GB 7000.1 Chapter 9 and the following requirements.
GB 7000.207-2008/IEC 60598-2-7. 1982
For lamps IP20 IP classification number greater than, the provisions of Section 9 of the GB 7000.1 test procedures in this section shall Chapter 12
get on.
13.1 Class Ⅱ garden shall be tested in the most unfavorable position near overturned with luminaries.
14 Insulation resistance and electric strength
Application of GB 7000.1 Chapter 10.
15 heat, fire resistance to tracking and
Application of GB 7000.1 Chapter 13.
GB 7000.207-2008/IEC 60598-2-7. 1982
......
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB 7000.207-2008_English be delivered?
Answer: Upon your order, we will start to translate GB 7000.207-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB 7000.207-2008_English with my colleagues?
Answer: Yes. The purchased PDF of GB 7000.207-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.