GB 30720-2025: Minimum allowable values of energy efficiency and energy efficiency grades for gas cooking appliances
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB30720-2025
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.010 CCS F 01 Replacing GB 30531-2014 and GB 30720-2014 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Gas Cooking Appliances Issued on. FEBRUARY 28, 2025 Implemented on. MARCH 1, 2026 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword... 3 1 Scope... 4 2 Normative References... 4 3 Terms and Definitions... 4 4 Energy Efficiency Grades... 5 5 Technical Requirements... 5 6 Test Methods... 6 Appendix A (normative) Test Method for the Thermal Efficiency of Steam Generators and Steam-generating Type Steam Boxes... 7Foreword
This document was drafted in accordance with the rules provided in GB/T 1.1-2020 Directives for Standardization - Part 1.Rules for the Structure and Drafting of Standardizing Documents. This document serves as a replacement for GB 30720-2014 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Domestic Gas Cooking Appliances and GB 30531-2014 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Commercial Gas Cooking Appliances. In comparison with GB 30720-2014 and GB 30531- 2014, apart from structural adjustments and editorial modifications, the main technical changes are as follows. a) The scope of application of the Standard is modified (see Chapter 1; Chapter 1 of GB 30720-2014 and Chapter 1 of GB 30531-2014); b) The definition and requirements of “evaluating values of energy conservation” are deleted (see 3.2 of GB 30720-2014 and 3.2 of GB 30531-2014); c) The energy efficiency grade requirements for domestic gas cooking appliances and commercial gas cooking appliances are modified (see 4.1; 4.2 of GB 30720-2014 and 4.2 of GB 30531-2014); d) The test methods are modified (see Chapter 5; Chapter 5 of GB 30720-2014 and Chapter 5 of GB 30531-2014); e) The inspection rules are deleted (see Chapter 6 of GB 30720-2014 and Chapter 6 of GB 30531-2014). Please be noted that certain content of this document may involve patents. The institution issuing this document does not undertake the responsibility of identifying these patents. This document was proposed by and shall be under the jurisdiction of Standardization Administration of the People’s Republic of China. The issuing of the previous versions. ---First issued in 2014 as GB 30720-2014 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Domestic Gas Cooking Appliances; ---This is the first revision, which incorporates the content of GB 30531-2014 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Commercial Gas Cooking Appliances. Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Gas Cooking Appliances1 Scope
This document specifies the energy efficiency grades, technical requirements and test methods for gas cooking appliances. This document is applicable to domestic gas stoves and integrated stoves with a rated heat load of not greater than 5.23 kw using town gas (hereinafter collectively referred to as “domestic gas cooking appliances”), and is also applicable to cooking stoves with a rated heat load of not greater than 60 kw, large pot stoves with a rated heat load of not greater than 80 kw, water-tank type and steam-generating type steam boxes and steam generators with a rated heat load of not greater than 80 kw (hereinafter collectively referred to as “commercial gas cooking appliances”). This document does not apply to gas cooking appliances used in means of transportation. NOTE. the rated heat load of domestic gas stoves and integrated stoves refers to the heat load of a single combustor; the rated heat load of cooking stoves, large pot stoves, steam boxes and steam generators refers to the heat load of a single combustion unit.2 Normative References
The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB 16410 Domestic Gas Cooking Appliances GB 35848-2024 Commercial Gas-burning Appliance3 Terms and Definitions
The terms and definitions defined in GB 16410 and GB 35848, and the following are applicable to this document. 3.1 minimum allowable values of energy efficiency for gas cooking appliances Under the test conditions specified in this document, the minimum thermal efficiency that a gas cooking appliance is allowed to achieve.4 Energy Efficiency Grades
4.1 Domestic Gas Cooking Appliances The energy efficiency grades of domestic gas cooking appliances are divided into 3 grades, among which, Grade 1 signifies the highest energy efficiency.5 Technical Requirements
5.1 Domestic Gas Cooking Appliances The minimum allowable values of energy efficiency of domestic gas cooking appliances shall comply with Grade 3 in Table 1.6 Test Methods
6.1 Domestic Gas Cooking Appliances 6.2 Commercial Gas Cooking Appliances 6.2.1 The test method for the thermal efficiency of steam generators and steam-generating type steam boxes shall be carried out in accordance with Appendix A. 6.2.2 The test conditions and test methods for water-tank type steam boxes, cooking stoves and large pot stoves shall be in accordance with GB 35848.Appendix A
(normative) Test Method for the Thermal Efficiency of Steam Generators and Steam-generating Type Steam Boxes A.1 General Requirements A.1.1 The test conditions shall satisfy the requirements of 6.14.1 in GB 35848-2024. A.1.2 The thermal efficiency test device shall satisfy the requirements of 6.14.2.1 in GB 35848- 2024. A.1.3 During the test, the outlet generating steam shall be connected to the steam inlet of the water-steam separator. The schematic diagram of the structure of the water-steam separator is shown in Figure A.1. A.2 Test Methods Follow the steps below to conduct the test. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.