Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Apr 4, 2020)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB 6830-1986

Chinese Standard: 'GB 6830-1986'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB 6830-1986English80 Add to Cart 0--15 minutes. Auto immediate delivery. The tolerable limits of danger on telecommunication lines from power lines Valid GB 6830-1986

  Google-Books (Full-PDF will be auto-delivered in 0~10 mins):   GB 6830-1986  GB/T 18487.2-2017
In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
GB 6830-1986
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
M 04
UDC 621.315 : 621.39
The tolerable limits of danger on telecommunication
lines from power lines
电信线路遭受强电线路危险影响的容许值
ISSUED ON: SEPTEMBER 02, 1986
IMPLEMENTED ON: OCTOBER 01, 1987
Issued by: National Bureau of Standard
The tolerable limits of danger on telecommunication
lines from power lines
1 Scope
This standard applies to the hazardous impact of all types of AC power lines,
AC electric railway contact networks, other strong electric lines on the adjacent
telecommunication lines (including telecommunication lines and cables, cable
broadcast lines, cables and broadcast audio cables) under the following status
and conditions*:
1.1 Fault status of high-voltage lines
1.1.1 The three-phase symmetrical neutral point directly grounded power line
has one-phase short-circuit grounded.
1.1.2 The three-phase symmetrical neutral point indirectly grounded power line
has two-phase short-circuit grounded simultaneously at different locations.
1.1.3 The three-phase symmetrical neutral point indirectly grounded power line
has one-phase short-circuit grounded.
1.1.4 AC electric railway contact network conductor is short-circuit grounded.
1.1.5 Other asymmetric power line conductor is short-circuit grounded.
1.2 Normal operation status of high-voltage line
1.2.1 AC electric railway contact network line operate normally.
1.2.2 Other asymmetric power lines operate normally.
1.3 Grounding current impact caused by ground short-circuit fault current of the
high-voltage system
Since the power line and the AC electric railway contact network system
generate ground potential in the area where the short-circuit fault current flows
into and out of the earth, it causes ground current impact onto the adjacent
telecommunication system (the local grounding device, the underground cable).
2 Hazardous current tolerance caused by electrical
induction
When a three-phase symmetrical neutral point indirectly grounded power line
has one-phase short-circuit grounding fault, as well as in the normal operation
status of AC electric railway contact network line and other asymmetric power
lines, if the human body touches the adjacent communication line, the tolerance
of current which is caused by the electric induction and flows through human
body is 15 mA (effective value).
3 Tolerable limits of dangerous longitudinal
electromotive force due to magnetic induction on
telecommunication open line
3.1 Fault status of high-voltage line (excluding the situation described in 1.1.2)
3.1.1 When the high-voltage line is a general power line or an AC electric
railway contact network, the tolerable limit of the longitudinal electromotive
force on the communication line is 430V (effective value, the same below).
3.1.2 When the high-voltage line is a highly reliable power line**, the tolerable
limit of the longitudinal electromotive force on the communication line is 650V.
3.1.3 Generally, when building a new high-voltage line or telecommunication
line, the main principle is to avoid the dangerous impact of the power line on
the telecommunication line. In the design process of the post-built line, the
corresponding measures are first adopted to make the dangerous longitudinal
electromotive force generated on the communication line not exceed the
tolerable limit. In the process of reviewing the design of the approaching
segment of two lines, when it is found that the induced longitudinal
electromotive force may exceed the tolerable limit, the ground voltage in the
accident state may be further calculated to ensure that it does not exceed the
tolerable limits as specified in 3.1.1 and 3.1.2 in various cases.
____________________________
* The tolerable limit of the telecommunication line for the field strength from the electros............
Related standard:   GB/T 3454-2011  GB/T 7400-2011
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2020