YY/T 1106-2008 (YY/T 1106-2023 Newer Version) PDF English


Search result: YY/T 1106-2008 (YY/T 1106-2023 Newer Version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1106-2023English319 Add to Cart 3 days (electric operating table) Valid
YY/T 1106-2008English150 Add to Cart 0-9 seconds. Auto-delivery. Electrically powered operating table Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): YY/T 1106-2023     Newer version: YY/T 1106-2023

PDF Preview: YY/T 1106-2008


YY/T 1106-2008: PDF in English (YYT 1106-2008)

YY/T 1106-2008 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.140 C 46 Replacing YY 91106-1999 Electrically powered operating table ISSUED ON. APRIL 25, 2008 IMPLEMENTED ON. JUNE 01, 2009 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Classification and basic size ... 4  4 Requirements ... 6  5 Test methods ... 7  6 Inspection rules ... 12  7 Markings, instructions for use, packaging, transport, storage ... 13  Foreword This standard is a recommended standard. This standard replaces YY 91106-1999 “Electrically powered operating table”. The main differences between this standard and YY 91106-1999 “Electrically powered operating table” are as follows. - MODIFY the safety requirements to be carried out in accordance with GB 9706.1-2007 “Medical electrical equipment - Part 1. General requirements for safety”; - Special requirements for safety shall be implemented in accordance with YY 0570-2005 “Medical electrical equipment - Part 2-46. Particular requirements for the safety of operating tables”; - MODIFY the environmental test requirements to be implemented in accordance with GB/T 14710-1993 “The environmental requirements and test methods for medical electrical equipment”; - DELETE the non-technical contents 4.7, 4.12, 4.13 of the technical requirements from the original standard; - UPDATE the outdated reference standards. This standard was proposed by the Medical Electronic Instruments Standardization Subcommittee of the National Medical Electrical Apparatus Standardization Technical Committee. This standard shall be under the jurisdiction of the Medical Electronic Instruments Standardization Subcommittee of the National Medical Electrical Apparatus Standardization Technical Committee. Drafting organization of this standard. Shanghai Medical Device Testing Institute. The main drafters of this standard. Xu Yuemin, Sun Jian. This standard replaces the standard previously issued as follows. - ZB C46 006-1989. - YY 91106-1999. Electrically powered operating table 1 Scope This standard specifies the classification, requirements, test methods, inspection rules and markings, instructions for use, packaging, transport, storage requirements for electrically powered operating table (hereinafter referred to as operating table). This standard applies to electrically powered operating table. This product is used for general surgery for thoracic and abdominal surgery, ophthalmology, otolaryngology, gynecology, obstetrics, and urology. 2 Normative references The provisions in following documents become the provisions of this standard through reference in this standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this standard; however, parties who reach an agreement based on this standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 191-2008 Packaging - Pictorial marking for handling of goods GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1.1988, IDT) GB 9969.1-1998 General principles for preparation of instructions for use of industrial products GB/T 14710-1993 The environmental requirements and test methods for medical electrical equipment YY 0570-2005 Medical electrical equipment - Part 2-46. Particular requirements for the safety of operating tables (IEC 60601-2-46.1998, IDT) 3 Classification and basic size 3.1 The type of operating table is electrically powered. hydraulic and/or pneumatic and/or mechanical. 3.2 The basic size of the operating table shall comply with the requirements of 4.8 The special requirements for the safety of the operating table shall comply with the provisions of YY 0570-2005. 4.9 The environmental test shall be in accordance with the provisions of the climatic environment test group II and the transport test in GB/T 14710-1993. 4.10 The of operating table shall be flat in appearance, uniform in color, free of defects such as scratches. 5 Test methods 5.1 Basic parameters. It is measured by the use a universal measuring tool. The results shall comply with the provisions of 4.1. 5.2 Leakage. The operating table shall be tested in accordance with 5.2.1 ~ 5.2.3 at 20 °C ± 5 °C. The results shall comply with the provisions of 4.2. 5.2.1 As shown in Figure 2, raise the table top to the highest position and keep it horizontally. Align the center of the column on the table top’s hip board, apply a 100 kg static load. After maintaining the hydraulic pressure for 5 h (or 1 h for pneumatic system), measure the falling distance. 5.2.2 As shown in Figure 3, lower the table top to a minimum and horizontal position, hang a 25 kg static load at the middle position of 100 mm from the end of leg board. After maintaining the hydraulic pressure for 5 h (or 1 h for pneumatic system), measure the falling distance. 5.2.3 As shown in Figure 4, lower the table top to the lowest position. Upward fold the back board to form an angle of 125° to the hip board. Hang a 50 kg static load at the middle of the top of the back board. After maintaining the hydraulic pressure for 5 h (or 1 h for pneumatic system), measure the falling distance. Figure 2 -- Leakage test (5.2.1) Wood board or corrugated paper 5.6 The table top and the selected table mat shall be visually inspected through X-ray (50 kV) or X-ray fluoroscopy (70 kV), it shall be free from shadow and comply with the requirements of 4.6. 5.7 General requirements for safety shall be tested in accordance with the method as specified in GB 9706.1, to verify whether it complies with the requirements. 5.8 Special requirements for safety shall be tested in accordance with the method as specified in YY 0570, to verify whether it complies with the requirements. 5.9 Environmental test requirements shall be tested in accordance with the method as specified in GB/T 14710, to verify whether it complies with the requirements. 5.10 Make visual observation. The results shall comply with the provisions of 4.10. 6 Inspection rules 6.1 Classification of inspections The inspection of electrically powered operating table products is divided into exit-factory inspection and type inspection. 6.2 Exit-factory inspection 6.2.1 The operating table shall be inspected by the quality inspection department of the manufacturer on a set-by-set basis. Only the qualified products can be warehoused-in and exit-factory. 6.2.2 The exit-factory inspection items shall be inspected according to the provisions of Table 2. 6.2.3 Among the inspection items, if there is any unqualified item, the unqualified item shall be repaired. After the repair, it shall be submitted again for inspection. Only the qualified products can be warehoused-in and exit- factory. Table 2 Inspection items Inspection range Remarks Performance 4.1, 4.2, 4.3, 4.4, 4.5, 4.10 - Safety 18 f), 19, 20 in GB 9706.1-2007 - 6.3 Type inspection g) Product’s standard number. 7.1.2 The wooden box shall have the following markings. a) The manufacturer’s name and address; b) The product’s name and model; c) The product’s production number; d) The product’s date of manufacture; e) The product’s registration number; f) The product’s standard number; g) The net weight and gross weight; h) The volume (length, width, height); i) “Fragile items”, “Keep upward”, “Avoid rain” and transport and storage markings, which shall be in accordance with the relevant provisions of GB/T 191. 7.2 Instruction for use The instruction for use shall comply with the requirements of GB 9969.1, 6.8 of GB 9706.1-2007, and relevant regulations on medical devices. 7.3 Packaging Each operating table together with the accessory box shall be placed in a wooden packing box, in which it is accompanied with one set of instruction for use, inspection certificate, packing list, respectively, which shall meet the following packing requirements. a) The wooden box shall have moisture-proof and rain-proof devices, to ensure that the product is not damaged naturally, the bottom of the box shall have sliding wood. b) The operating table must be firmly positioned in the box. It shall place a soft mat of appropriate thickness at the contact plane between the pressing wood and the product, to avoid loosening or friction during transport. c) The inspection certificate shall have the following markings. 1) The manufacturer’s name or trademark; ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.