SN/T 3644-2013 PDF English
US$205.00 · In stock · Download in 9 secondsSN/T 3644-2013: Determination of Sialic acid in cubilose and its products for export Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
SN/T 3644-2013 | English | 205 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Determination of Sialic acid in cubilose and its products for export
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: SN/T 3644-2013
SN/T 3644-2013: Determination of Sialic acid in cubilose and its products for export---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/SNT3644-2013
SN
ENTRY-EXIT INSPECTION AND QUARANTINE STANDARD
Determination of Sialic acid in cubilose and its products for
export
Issued on: AUGUST 30, 2013
Implemented on: MARCH 01, 2014
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China
Table of Contents
Foreword... 3
1 Scope... 4
2 Method summary... 4
3 Safety tips... 4
4 Reagents and materials... 4
5 Instruments and equipment... 5
6 Sample preparation... 6
7 Determination steps... 6
8 Result calculation and expression... 9
9 Lower determination limits... 10
Annex A (informative) Mass spectrum of sialic acid standard... 11
Determination of Sialic acid in cubilose and its products for
export
1 Scope
This Standard specifies the spectrophotometric method and liquid chromatography-
mass spectrometry/mass spectrometry confirmation method for the detection of sialic
acid in cubilose and its products for export.
This Standard applies to the measurement and confirmation of sialic acid content in
cubilose and its products for export.
2 Method summary
The glycoprotein in the cubilose is hydrolyzed with acetic acid. The released sialic acid
forms a stable yellow compound with acidic ninhydrin. It is quantitatively determined
by spectrophotometry and confirmed by liquid chromatography-mass
spectrometry/mass spectrometry.
3 Safety tips
Some of the test processes in this method may lead to dangerous situations. Some of
the reagents used are corrosive or irritating. There are also high-temperature heating
processes, so be careful when operating! The operator should take appropriate safety
and health measures. Wear rubber gloves or cotton gloves when necessary.
4 Reagents and materials
Unless otherwise specified, all reagents used are analytically pure and the water used is
laboratory grade 3 water.
4.1 Methanol. HPLC grade.
4.2 Glacial acetic acid.
4.3 50% acetic acid solution. measure 50 mL of glacial acetic acid and 50 mL of water
respectively, mix well and set aside.
4.4 Hydrochloric acid.
4.5 Ammonium sulfate.
4.6 Ninhydrin.
4.7 Ninhydrin indicator. add 60 mL of glacial acetic acid and 40 mL of hydrochloric
acid to 2.5 g of ninhydrin, stir and dissolve.
4.8 Dialysis bag. molecular weight cutoff is 14000.
4.9 Sialic acid standard substance (N-Acetylneuraminic acid, CAS No. is 131-48-6).
Purity ≥ 99%, stored at -18°C.
4.10 Sialic acid standard solution (200 μL/mL). accurately weigh an appropriate
amount of sialic acid standard substance and prepare a sialic acid standard solution with
a concentration of 200 μg/mL with water. Prepare the solution when needed.
4.11 Zeolite.
5 Instruments and equipment
5.1 Visible spectrophotometer.
5.2 Liquid chromatography-mass spectrometry/mass spectrometry. equipped with
electrospray ion source.
5.3 Oven. 102°C~105°C.
5.4 Mortar.
5.5 Sieve. 100 mesh.
5.6 Electronic balance. sensitivity is 0.01 mg and 0.001 g.
5.7 Frosted mouth triangle bottle. 250 mL.
5.8 Heating equipment. flat electric furnace.
5.9 Condensation reflux device.
5.10 Centrifuge tube. 50 mL, polypropylene (PP).
5.11 Centrifuge. 3000 r/min, 12000 r/min.
5.12 Colorimetric tube. 10 mL, glass.
5.13 Cuvette. 1 cm, quartz.
5.14 Container. 100 mL, glass.
5.15 Pipette gun. 2 mL, 10 mL.
6 Sample preparation
6.1 Preparation of solid cubilose
Take the cubilose sample and dry it in a 105°C oven. Grind it after cooling in a dryer.
Pass it through a 100-mesh sieve and put it into a clean container. Seal it for later use.
6.2 Preparation of cubilose products
For liquid cubilose products, use a pulper to make samples. Let stand and wait for the
foam and sample liquid to separate, then decant the foam (or use a centrifuge to
separate). Take an appropriate amount of the supernatant and put it into a dialysis bag
(4.8). Dialyze in running water for 24 h. Put the dialyzed sample liquid into a clean
container. Seal it for later use.
7 Determination steps
7.1 Sialic acid extraction
7.1.1 Extraction of solid sialic acid
Weigh 0.1 g (accurate to 0.001 g) of sample powder (6.1) into a frosted conical flask.
Add 20.0 mL of 50% acetic acid solution (4.3). Add a few zeolites. Place on a heating
plate. Install the condenser reflux tube and heat to boiling. Time for 10 min. Remove
the conical flask. The flask wall can be quickly cooled with running water. After the
hydrolyzate cools to room temperature, transfer it to a 100 mL volumetric flask through
a funnel. Wash the conical flask twice with an appropriate amount of water. Finally,
make up to the volume with distilled water. After shaking well, pour 10.0 mL into a
centrifuge tube with 1.2 g of ammonium sulfate. Stir well with a glass rod. Dissolve the
ammonium sulfate. Tighten the lid. Place in a centrifuge. Centrifuge at 3000 r/min for
10 min. Set aside the supernatant.
7.1.2 Extraction of sialic acid from liquid cubilose products
Weigh 10 g (accurate to 0.001 g) of sample solution (6.2) into a frosted conical flask.
Add 10.0 mL of glacial acetic acid and a few zeolites. Place on a heating plate. Install
a condenser reflux tube. Heat to boiling. Time for 10 min. Remove the conical flask.
The flask wall can be quickly cooled with running water. After the hydrolyzate has
cooled to room temperature, transfer it to a 100 mL volumetric flask through a funnel.
Wash the conical flask twice with an appropriate amount of water. Finally, make up to
the volume with distilled water. After shaking well, pour 10.0 mL into a centrifuge tube
with 1.2 g of ammonium sulfate. Stir well with a glass rod to dissolve the ammonium
sulfate. Tighten the lid. Place in a centrifuge. Centrifuge at 3000 r/min for 10 min. Set
aside the supernatant.
If the cubilose product is very thick and easily burns when heated and hydrolyzed,
weigh 5 g (accurate to 0.001 g) and add 15.0 mL of 50% acetic acid solution. Follow
the same steps as above.
7.2 Determination of sialic acid content
7.2.1 Determination by spectrophotometry
Take 2.0 mL of the supernatant (7.1) and place it in a 10 mL colorimetric tube. Then
add 2.0 mL of ninhydrin indicator (4.7) and 2.0 mL of glacial acetic acid. Shake well.
Develop the color in a 100°C water bath for 10 min. Take out the test tube and cool it
quickly in running water. Then pour it into a 1 cm colorimetric dish. Measure the
absorbance at a wavelength of 470 nm. Adjust the zero point with a reagent blank tube.
If the absorbance exceeds the measurement range of the spectrophotometer, dilute the
test solution (7.1).
Blank test. Substitute distilled water as the specimen. Proceed according to the above
measurement steps.
Standard curve. Dilute the sialic acid standard solution (4.10) stepwise to 100 μg/mL,
50 μg/mL, 20 μg/mL, 10 μg/mL, and 5 μg/mL. Take 2.0 mL of each standard dilution
into a 10 mL colorimetric tube. Add 2.0 mL of ninhydrin indicator (4.7) and 2.0 mL of
glacial acetic acid. Shake well. Develop the color in a 100°C water bath for 10 min.
Take out the test tube and cool it quickly in running water. Then use a 1 cm colorimetric
dish to measure the absorbance at a wavelength of 470 nm. Prepare a standard working
curve based on the concentration and absorbance of the standard solution.
7.2.2 Determination by liquid chromatography-mass spectrometry/mass
spectrometry
7.2.2.1 Determination steps
When identifying cubilose samples, liquid chromatography-mass spectrometry/mass
spectrometry can be used for confirmation based on spectrophotometric analysis.
Perform hydrolysis pretreatment on the cubilose sample to be confirmed according to
6.1.Take 50 μL of the obtained supernatant. Add 900 μL of methanol. Mix well.
Centrifuge at 12000 r/min for 10 min. Take 50 μL of the supernatant again. Add 900 μL
of mobile phase. Mix well. Filter. Apply to the machine.
7.2.2.2 Liquid chromatography conditions
The liquid chromatography conditions are as follows.
a) Chromatographic column. C18, 150×2.1 mm, 3 μm; or other chromatographic
columns with equivalent performance;
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of SN/T 3644-2013 be delivered?Answer: The full copy PDF of English version of SN/T 3644-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of SN/T 3644-2013_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3644-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- SN/T 3644-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of SN/T 3644-2013?A step-by-step guide to download PDF of SN/T 3644-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "SN/T 3644-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|