HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

QC/T 1177-2022 PDF English

US$170.00 · In stock · Download in 9 seconds
QC/T 1177-2022: Condenser for automotive air conditioning
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
QC/T 1177-2022English170 Add to Cart 0-9 seconds. Auto-delivery Condenser for automotive air conditioning Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: QC/T 1177-2022
      

Similar standards

QC/T 1176   QC/T 1170   QC/T 1148   QC/T 1182   

QC/T 1177-2022: Condenser for automotive air conditioning

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/QCT1177-2022
QC AUTOMOTIVE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.040.60 CCS T 26 Condenser for automotive air conditioning ISSUED ON: APRIL 08, 2022 IMPLEMENTED ON: OCTOBER 01, 2022 Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Table of Contents

Foreword ... 6 1 Scope ... 7 2 Normative references ... 7 3 Terms and definitions ... 7 4 Technical requirements ... 8 5 Test methods ... 11 6 Inspection rules ... 15 7 Marks, packaging, transportation and storage ... 16

Foreword

This document was drafted in accordance with the rules given in GB/T 1.1-2020 "Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents". This document was proposed by and shall be under the jurisdiction of National Technical Committee on Automobile of Standardization Administration of China (SAC/TC 114). The drafting organizations of this document: Longquan Industrial Innovation Service Center, Automobile Air Conditioning Committee of China Association of Automobile Manufacturers, Shanghai Kallang Songzhi Automotive Air Conditioning Co., Ltd., Longquan Huibo Technology Co., Ltd., Zhejiang Longteng Air Conditioning Co., Ltd., South Intel Air Conditioning Co., Ltd., Air Conditioning International (Shanghai ) Co., Ltd., Dongfeng Motor Group Co., Ltd. Technology Center, Zhejiang University, Chongqing Chaoli High-Tech Co., Ltd., Zhejiang Xinjin Air Conditioning Equipment Co., Ltd., Shanghai Tianmiao Air Treatment Equipment Co., Ltd., Shanghai Satake Cooling and Heat Control Technology Co., Ltd., Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Jilin University, Shenyang Ziweiheng Testing Equipment Co., Ltd., Tianjin Gertes Testing Equipment Technology Development Co., Ltd., Shenyang Huifuxiang Precision Machinery Co., Ltd., Yuxin Automobile Thermal Management Technology Co., Ltd., Hangzhou Three Hua Research Institute Co., Ltd., Zhongyuan Institute of Technology, Zhengzhou Kelin Automotive Air Conditioning Co., Ltd., Yinbang Metal Composite Materials Co., Ltd., Wuhu Tonglian Auto Parts Co., Ltd., China FAW Group Co., Ltd. Research and Development Institute, China Automotive Research Institute Inspection Center (Tianjin) Co., Ltd., Dongfeng Motor Co., Ltd., BYD Auto Industry Co., Ltd., Helong Shuanghao High-tech Co., Ltd., Zhejiang Lantong Air Conditioning Equipment Co., Ltd., Zhejiang Innovation Automobile Air Conditioning Co., Ltd. Main drafters of this document: Xiong Shusheng, Ye Jun, Xue Qingfeng, Guo Guoqi, Qin Feng, Tong Guohai, Sun Lei, Yang Jinhui, Shen Jie, Jing Xiaoping, Zhou Linsen, Ye Fangping, He Lijiang, Fan Liqun, Zou Huiming, Li Ming, Zhang Jinsheng, Cai Zhixiong, Liu Hui, Chen Yong, Wu Zhaosu, Dong Junqi, Ji Liyou, Li Peng, Ji Zhihao, Liu Liu, Xie Yanan, Liu Zhao, Zhou Guanghui, Shi Hongchen, Zhang Xiaojun, Bian Jiachen, Xu Minli, Gao Yanan, He Genping, Chen Xuefeng, Chen Dairong, Xu Minwu, Ye Weifeng, Ye Jianjie, Zhang Li. This document is issued for the first time. Condenser for automotive air conditioning

1 Scope

This document specifies the technical requirements, test methods, inspection rules and marks, packaging, transportation and storage of condensers for automotive air conditioning (condensers for short). This document applies to air-cooled condensers for exterior use, heat pump type interior air-cooled condensers and air-cooled condensers with liquid storage tanks using HFC- 134a and HFO-1234yf as refrigerants.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191, Packaging and storage marks GB/T 6287, Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements GB/T 10125, Corrosion tests in artificial atmospheres - Salt spray tests GB/T 21361, Motor vehicle air-conditioning unit

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 21361 as well as the followings apply. 3.1 condenser A heat exchanger that cools and condenses gaseous refrigerant into a liquid state. 3.2 stable state During the test, the state that the fluctuation range of the relevant test parameters is less than the specified value. 3.3 heat exchange Operating under the specified test conditions, the heat dissipated into the air by the condenser per unit time. 3.4 air pressure drop Operating under the specified test conditions, the pressure difference1 between the air inlet surface and the air outlet surface of the condenser. 3.5 refrigerant pressure drop Operating under the specified test conditions, the pressure difference between the refrigerant inlet and outlet of the condenser. 3.6 subcooling condenser A heat exchanger that cools the high-temperature and high-pressure gaseous refrigerant entering the condenser into a high-temperature and high-pressure liquid refrigerant, and the liquid refrigerant at the outlet of the condenser has a certain degree of subcooling.

4 Technical requirements

4.1 Dimensional tolerance and appearance requirements Inspect according to 5.1. The dimensional tolerance and appearance requirements of the product shall comply with the agreement between the supplier and the purchaser. 4.2 Heat exchange, air pressure drop and refrigerant pressure drop Test according to 5.2. The air side heat exchange, refrigerant side heat exchange, air pressure drop and refrigerant pressure drop of the condenser shall be in accordance with the agreement between the supplier and the purchaser. 4.3 Airtight performance 4.3.1 Airtight performance of helium test Carry out airtight performance test of helium test according to 5.3.1. The helium leakage rate of the product shall not be greater than 1×10-3 Pa·L/s (refrigerant equivalent leakage rate is 2 g/y). 4.3.2 Airtight performance of water test Carry out airtight performance test of water test according to 5.3.2. The product shall be free of air bubbles. 4.4 Residual impurities in the inner cavity 1 Pressures in this document are gauge pressures unless otherwise specified. Carry out the test according to 5.4. The mass of residual impurities in the product cavity shall not exceed 20 mg/m2. The diagonal outer diameter of particles shall not be greater than 0.2mm. 4.5 Residual water amount in the inner cavity Carry out the test according to 5.5. The residual water amount in the inner cavity of the product shall not exceed 40 mg/m2. 4.6 Pressure resistance Carry out the test according to 5.6. The product shall be free from damage and abnormal deformation and meet the requirements of 4.3.2. 4.7 Burst pressure Carry out the test according to 5.7. The product shall not break under the pressure of 8.8 MPa. 4.8 Vacuum resistance Carry out the test according to 5.8. The product shall be free from leakage, damage and abnormal deformation. The pressure rise rate after the test shall not exceed 0.5 kPa/min. 4.9 Pressure alternating performance Carry out the test according to 5.9. The product shall have no abnormal deformation or crack and meet the requirements of 4.3.2. 4.10 Vibration resistance Carry out the test according to 5.10. The product shall be free from looseness, damage and leakage and meet the requirements of 4.3.2. 4.11 Corrosion resistance Carry out the test according to 5.11.1. The heat pump type air-cooled condenser in the vehicle shall be tested according to 5.11.2 .The outer surface of the product shall be free of air bubbles or peeling off and meet the requirements of 4.3.2. 4.12 High temperature storage Carry out the test according to 5.12. The appearance of the product shall be free from abnormal deformation or damage and meet the requirements of 4.3.2. 4.13 Low temperature storage Carry out the test according to 5.13. The appearance of the product shall be free from abnormal deformation or damage and meet the requirements of 4.3.2. total duration shall not be less than 30 min. Take the arithmetic mean value of the parameters read within this time period as the measurement result. 5.2.4 If the heat exchange ratio of the air side and the refrigerant side is less than 95%, the data shall be re-measured. 5.3 Air tightness test 5.3.1 Air tightness test of helium test Use vacuum box type helium leak detection equipment. Fill the cavity with helium at a pressure of 0.8 MPa. The pressure holding time is 1 min. 5.3.2 Air tightness test of water test Seal one end of the condenser inlet and outlet pipe. The other end is fed with dry air or nitrogen. Hold the pressure at 3.5MP±0.1MPa. Place the product in water. The test time is 3 min. 5.4 Mass test of residual impurities in the inner cavity 5.4.1 Inject about 60% of the volume of isooctane into the inner cavity of the tested product. Shake up and down, left and right, and back and forth 4~5 times. Then recover the dissolved matter in a special container. Filter and dry with 8μm filter paper. Determine the mass of residual material. Use industrial analytical tools to measure. The measurement accuracy is ±0.1 mg. Particle size is measured microscopically. 5.4.2 If the condenser is equipped with a filter drying bag, it shall be removed before the test. 5.5 Cavity residual water test 5.5.1 Connect the condenser inlet to the nitrogen tank. The outlet is connected to the inlet of the trace moisture meter. Introduce nitrogen into the condenser at a rate of 70 mL/min ± 20 mL/min. When the fluctuation of the test value does not exceed 0.1 mg and lasts for more than 3 min, read the residual water amount as the test result. The accuracy of the trace moisture meter is ±0.05 mg. 5.5.2 If the condenser is equipped with a filter drying bag, it shall be removed before the test. 5.6 Pressure resistance test One end of the inlet and outlet pipe of the condenser is sealed. The other end is passed into water or hydraulic oil to pressurize. Pressurize at a rate of 1 MPa/min ± 0.5 MPa/min to 4.41 MPa ± 0.05 MPa. Hold the pressure for 3 min. 5.7 Burst pressure test Evacuate the condenser first. Seal one end of the inlet and outlet pipe. The other end is introduced to water or hydraulic oil. Pressurize at a rate of 1 MPa/min ± 0.05 MPa/min to 8.8 MPa ± 0.05 MPa. Maintain 3 min. Then boost the pressure until it explodes. Record the pressure value before the condenser burst. 5.8 Vacuum resistance test Seal one end of the condenser's inlet and outlet pipe. The other end is evacuated to 2 kPa. Conduct 3 consecutive times. Maintain 5 min each time. 5.9 Pressure alternating performance test Carry out alternating pressure test according to the requirements of Table 3. The test medium is hydraulic oil. 5.10 Vibration resistance test 5.10.1 Test preparation According to the actual vehicle installation status, install the condenser on the vibration test bench. 5.10.2 Resonance frequency testing 5.10.2.1 Set the vibration frequency to 8.3 Hz ~ 200 Hz. The vibration acceleration is set to 9.8 m/s2. Carry out vibration test in up and down direction. The test time does not exceed 20 min. 5.10.2.2 If at a certain frequency, the measured acceleration is more than twice the input acceleration, then this frequency is the resonance frequency. For products with no resonant frequency detected, carry out the vibration resistance performance test according to 5.10.3. For the products whose resonant frequency is measured, carry out the vibration resistance performance test according to 5.10.4. 5.10.3 Vibration resistance performance test without resonance point Set the vibration frequency to 33.3 Hz. The vibration acceleration is set to 32.3 m/s2. Vibrate 7.5 × 105 times in the up and down direction. Vibrates 2.5 × 105 times along the front and back. 5.10.4 Vibration resistance performance test with resonance point 5.10.4.1 According to the resonance frequency range, complete the corresponding vibration test according to the requirements in Table 4. 5.10.4.2 If there is more than one resonant frequency range, the samples for vibration tests of different frequency ranges may not be the same sample. 5.10.4.3 After the test under the conditions specified in Table 4, the test without resonance frequency as described in 5.10.3 shall be carried out. 5.11 Corrosion resistance test 5.11.1 Acid salt spray test Put the condenser into the salt spray corrosion test chamber. Carry out the salt spray test according to the test method of acetic acid salt spray test (AASS test) in GB/T 10125. The test time is 500 h. 5.11.2 Neutral salt spray test Put the condenser into the salt spray corrosion test chamber. According to the provisions of GB/T 10125, carry out 480 h neutral salt spray corrosion test. 5.12 High temperature storage test Place at 120°C ± 3°C for 72 h. Recover to normal temperature. 5.13 Low temperature storage test Place at -40°C ± 3°C for 72 h. Recover to normal temperature. 5.14 Temperature cycle test Test according to Figure 1. Complete 10 temperature cycles. After the test, the samples are left at room temperature for 20 min.

6 Inspection rules

6.1 Inspection classification 6.1.1 Exit-factory inspection Each condenser shall be exit-factory inspected. The inspection items, technical requirements and test methods shall be carried out according to Table 5. 6.1.2 Type inspection 6.1.2.1 Type inspection conditions Type inspection shall be carried out under the following conditions. The inspection items are carried out according to Table 5: a) When product development is approved; b) When there are major changes in the design, process, materials of the product; c) When the production that has been discontinued for 1 year is resumed; d) When the quality is unstable, and it is deemed necessary; e) When it is required by the quality supervision department; f) After normal mass production, when the time interval from the previous type inspection exceeds 1 year. 6.1.2.2 Type inspection method Samples are randomly selected from the products that have passed the exit-factory inspection. The same product is allowed to participate in multiple tests that do not affect its technical requirements. The product shall be marked with a permanent mark in a conspicuous position. 7.1.2 Product mark content The mark shall include the following: a) Name or trademark of the manufacturer; b) Product model; c) Refrigerant type; d) Production date or production batch number; e) Recyclability sign. 7.2 Packaging, transportation 7.2.1 Product packing box The following content shall be marked on the outside of the product package: a) Name and address of the manufacturer; b) Product name, model and quantity; c) Production date, production batch number or its code; d) Mass (total mass); e) Dimensions of the packing box. 7.2.2 Marks The packaging shall have marks such as "Handle with care", "Up" and "Afraid of wetness". The marks shall comply with the relevant provisions of GB/T 191. 7.2.3 Certificate of conformity Products shall have a certificate of conformity. 7.2.4 Product packaging and shipping method Product packaging and transportation shall have reliable dust-proof, moisture-proof and shock-proof measures. Guarantee that the product will not be loosened or damaged during normal transportation. 7.3 Storage The product shall be stored in a well-ventilated and dry environment. There is no ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of QC/T 1177-2022 be delivered?

Answer: The full copy PDF of English version of QC/T 1177-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of QC/T 1177-2022_English with my colleagues?

Answer: Yes. The purchased PDF of QC/T 1177-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- QC/T 1177-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of QC/T 1177-2022?

A step-by-step guide to download PDF of QC/T 1177-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "QC/T 1177-2022".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9