HOME   Cart(8)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

QC/T 1176-2022 PDF English

US$170.00 · In stock · Download in 9 seconds
QC/T 1176-2022: Evaporator for automotive air conditioning
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
QC/T 1176-2022English170 Add to Cart 0-9 seconds. Auto-delivery Evaporator for automotive air conditioning Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: QC/T 1176-2022
      

Similar standards

QC/T 1177   QC/T 1170   QC/T 1148   QC/T 1182   

QC/T 1176-2022: Evaporator for automotive air conditioning

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/QCT1176-2022
QC AUTOMOTIVE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.040.60 CCS T 26 Evaporator for automotive air conditioning ISSUED ON: APRIL 08, 2022 IMPLEMENTED ON: OCTOBER 01, 2022 Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Table of Contents

Foreword ... 6 1 Scope ... 7 2 Normative references ... 7 3 Terms and definitions ... 7 4 Technical requirements ... 8 5 Test methods ... 9 6 Inspection rules ... 13 7 Marks, packaging, transportation and storage ... 15 Evaporator for automotive air conditioning

1 Scope

This document specifies the technical requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of evaporator for automotive air conditioning (referred to as the evaporator). This document is applicable to the evaporator for automotive air conditioning that uses HFC-134a and HFO-1234yf as refrigerants.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191, Packaging and storage marks GB/T 10125, Corrosion tests in artificial atmospheres - Salt spray tests GB/T 21361, Motor vehicle air-conditioning unit

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 21361 as well as the followings apply. 3.1 evaporator A heat exchanger that cools the air by vaporization of the refrigerant. 3.2 stable state During the test, the state that the fluctuation range of the relevant test parameters is less than the specified value. 3.3 refrigerating capacity Operating under the specified test conditions, the heat in the air that is absorbed by the evaporator per unit time. 3.4 air pressure drop Operating under the specified test conditions, the pressure difference1 between the air inlet surface and the air outlet surface of the evaporator. 3.5 refrigerant pressure drop Operating under the specified test conditions, the pressure difference between the refrigerant inlet and outlet in the evaporator.

4 Technical requirements

4.1 Dimensional tolerance and appearance requirements Inspect according to 5.1. The dimensional tolerance and appearance requirements of the product shall comply with the agreement between the supplier and the purchaser. 4.2 Refrigerating capacity, air pressure drop and refrigerant pressure drop Test according to 5.2. The refrigerating capacity of the evaporator, the air pressure drop and the refrigerant pressure drop shall meet the requirements negotiated and determined by both parties. 4.3 Airtight performance 4.3.1 Airtight performance of helium test Carry out airtight performance test of helium test according to 5.3.1. The helium leakage rate of the product shall not be greater than 1×10-3 Pa·L/s (refrigerant equivalent leakage rate is 2 g/y). 4.3.2 Airtight performance of water test Carry out airtight performance test of water test according to 5.3.2. The product shall be free of air bubbles. 4.4 Residual impurities in the inner cavity Carry out the test according to 5.4. The mass of residual impurities in the product cavity shall not exceed 20 mg/m2. The diagonal outer diameter of particles shall not be greater than 0.5mm. 4.5 Residual water amount in the inner cavity Carry out the test according to 5.5. The residual water amount in the inner cavity of the product shall not exceed 40 mg/m2. 4.6 Pressure resistance 1 Pressures in this document are gauge pressures unless otherwise specified. Carry out the test according to 5.6. The product shall be free from damage and abnormal deformation and meet the requirements of 4.3.2. 4.7 Burst pressure Carry out the test according to 5.7. The product shall not break under the pressure of 2.8 MPa. 4.8 Vacuum resistance Carry out the test according to 5.8. The product shall be free from leakage, damage and abnormal deformation. The pressure rise rate after the test shall not exceed 0.5 kPa/min. 4.9 Pressure alternating performance Carry out the test according to 5.9. The product shall have no abnormal deformation or crack and meet the requirements of 4.3.2. 4.10 Vibration resistance Carry out the test according to 5.10. The product shall be free from looseness, damage and leakage and meet the requirements of 4.3.2. 4.11 Corrosion resistance Carry out the test according to 5.11. The outer surface of the product shall be free of air bubbles or peeling off and meet the requirements of 4.3.2. 4.12 High temperature storage Carry out the test according to 5.12. The appearance of the product shall be free from abnormal deformation or damage and meet the requirements of 4.3.2. 4.13 Low temperature storage Carry out the test according to 5.13. The appearance of the product shall be free from abnormal deformation or damage and meet the requirements of 4.3.2. 4.14 Temperature cycle Carry out the test according to 5.14. The appearance of the product shall be free from abnormal deformation or damage and meet the requirements of 4.3.2.

5 Test methods

5.1 Dimensional tolerance and appearance Dimensional tolerances are checked with measuring tools. The appearance is detected 5.3.1 Air tightness test of helium test Use vacuum box type helium leak detection equipment. Fill the cavity with helium at a pressure of 0.5 MPa±0.05 MPa. The pressure holding time is 1 min. 5.3.2 Air tightness test of water test Seal one end of the evaporator inlet and outlet pipe. The other end is fed with dry air or nitrogen. Place in water. The pressure reaches 1.5MPa±0.05MPa. Hold the pressure for 3 min. 5.4 Mass test of residual impurities in the inner cavity Inject about 60% of the volume of isooctane into the inner cavity of the tested product. Shake up and down, left and right, and back and forth 4~5 times. Then recover the dissolved matter in a special container. Filter and dry with 8μm filter paper. Determine the mass of residual material. Use industrial analytical tools to measure. The measurement accuracy is ±0.1 mg. Particle size is measured microscopically. 5.5 Cavity residual water test Connect the evaporator inlet to the nitrogen tank. The outlet is connected to the inlet of the trace moisture meter. Introduce nitrogen into the evaporator at a rate of 70 mL/min ± 20 mL/min. When the fluctuation of the test value does not exceed 0.1 mg and lasts for more than 3 min, read the residual water amount as the test result. The accuracy of the trace moisture meter is ±0.05 mg. 5.6 Pressure resistance test One end of the inlet and outlet pipe of the evaporator is sealed. The other end is passed into water or hydraulic oil to pressurize. Pressurize at a rate of 1 MPa/min ± 0.5 MPa/min to 2.21 MPa ± 0.05 MPa. Hold the pressure for 3 min. 5.7 Burst pressure test Evacuate the evaporator first. Seal one end of the inlet and outlet pipe. The other end is introduced to water or hydraulic oil. Pressurize at a rate of 1 MPa/min ± 0.05 MPa/min to 2.8 MPa±0.05 MPa. Maintain 3 min. Then boost the pressure until it explodes. Record the pressure value before the evaporator burst. 5.8 Vacuum resistance test Seal one end of the evaporator's inlet and outlet pipe. The other end is evacuated to 2 kPa. Conduct 3 consecutive times. Maintain 5 min each time. 5.9 Pressure alternating performance test Carry out alternating pressure test according to the requirements of Table 3. The test Each evaporator shall be exit-factory inspected. The inspection items, technical requirements and test methods shall be carried out according to Table 5. 6.1.2 Type inspection 6.1.2.1 Type inspection conditions Type inspection shall be carried out under the following conditions. The inspection items are carried out according to Table 5: a) When product development is approved; b) When there are major changes in the design, process, materials of the product; c) When the production that has been discontinued for one year is resumed; d) When the quality is unstable, and it is deemed necessary; e) When it is required by the quality supervision department; f) After normal mass production, when the time interval from the previous type inspection exceeds 1 year. 6.1.2.2 Type inspection method Samples are randomly selected from the products that have passed the exit-factory inspection. The same product is allowed to participate in multiple tests that do not affect its technical requirements. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of QC/T 1176-2022 be delivered?

Answer: The full copy PDF of English version of QC/T 1176-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of QC/T 1176-2022_English with my colleagues?

Answer: Yes. The purchased PDF of QC/T 1176-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- QC/T 1176-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of QC/T 1176-2022?

A step-by-step guide to download PDF of QC/T 1176-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "QC/T 1176-2022".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9