HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JG/T 231-2018 PDF English

US$290.00 · In stock · Download in 9 seconds
JG/T 231-2018: Technical requirements of building glass skylight system
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JG/T 231: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
JG/T 231-2018English290 Add to Cart 0-9 seconds. Auto-delivery Technical requirements of building glass skylight system Valid
JG/T 231-2007English160 Add to Cart 0-9 seconds. Auto-delivery Building glass skylight system Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: JG/T 231-2018
      

Similar standards

JGJ/T 231   GB/T 8478   JG/T 228   

JG/T 231-2018: Technical requirements of building glass skylight system

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JGT231-2018
CONSTRUCTION INDUSTRY INDUSTRIAL STANDARD ICS 91.060.20 P 32 Replacing JG/T 231-2007 Technical requirements of building glass skylight system Issued on. JUNE 26, 2018 Implemented on. DECEMBER 01, 2018 Issued by. Ministry of Housing and Urban-Rural Development of the People's Republic of China

Table of Contents

Foreword... 3 1 Scope... 5 2 Normative references... 5 3 Terms and definitions... 8 Annex A (informative) Detection limit of different matrix specimens... 33 Annex B (informative) Chromatogram of organochlorine pesticide mixed standard solution... 33 Annex C (informative) Method uncertainty... 36 Bibliography... Error! Bookmark not defined.

1 Scope

This Standard specifies the terms and definitions, classification and marks, general requirements, materials and components, production and assembly requirements, requirements and test methods. This Standard is applicable to building glass skylight system.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2680, Determination of light transmittance, solar direct transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors GB/T 4171, Atmospheric corrosion resisting structural steel GB/T 5117, Covered electrodes for manual metal arc welding of non-alloy and fine grain steels GB/T 5118, Covered electrodes for manual metal arc welding of creep- resisting steels GB/T 5224, Steel strand for prestressed concrete GB/T 5237 (all parts), Wrought aluminium alloy extruded profiles for architecture GB/T 8485, The graduation and test for airborne sound insulating properties of windows and doors GB 8624, Classification for burning behavior of building materials and products

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. 3.1 building glass skylight system glass skylight system for short 4 Classification and marks 4.1 Classification 4.1.1 According to the supporting structure, it can be divided into steel structure (G), cable rod structure (S), aluminum alloy structure (L), glass beam structure (B). 4.2 Marks 4.2.1 Marking method The mark is composed of the product code of the glass skylight system (CGD), standard code, support structure category code, opening-closing category code, closed category code, and main parameters (structural performance). 4.2.2 Marking example Example. CGD-S-K-FB/3.5-JG/T231, which represents a closed glass skylight system that is supported by cable rod structure, is openable, the structural performance is 3.5kPa and complies with the industrial standard JG/T 231. 5 General requirements 5.1 The materials used for glass skylight system shall meet the relevant regulations of the current national standards, see Annex A. There shall be exit- factory certificate and quality certificate. 5.3 The area of glass panel used for glass skylight system shall not exceed 2.5m2.The length of the long side shall not be greater than 2m. 5.7 The energy-saving design of glass skylight system shall comply with the requirements of GB 50176, GB 50189, JGJ 26, JGJ 75 and JGJ 134. 5.8 The durability of glass skylight system, anti-condensation (frost, ice) and hail resistance shall meet the design requirements. 5.15 The visible light transmittance of glass skylight system shall meet the lighting design requirements. A glass panel with visible light reflectance not greater than 0.30 is preferred. 6 Materials and components 6.1 Aluminum alloy profile 6.1.1 The base material of aluminum alloy profile shall meet the requirements of GB/T 5237.1.The allowable size deviation shall meet the requirements of high precision or ultra-high precision. 6.1.2 When aluminum alloy profiles using anodizing, electrophoretic painting, powder spraying, fluorocarbon paint spraying for surface treatment, it shall respectively comply with the requirements of GB/T 5237.2, GB/T 5237.3, GB/T 5237.4, and GB/T 5237.5.The thickness of the surface treatment layer shall meet the requirements of Table 1. 6.3 Pull rod 6.3.1 Steel ropes for glass skylight system shall use steel strands. The nominal diameter of the steel strand of the main load steel rope shall not be less than 12mm and shall meet the design requirements. 6.3.2 Zinc-5% aluminum-mixed rare earth alloy coated steel strands shall meet the requirements of GB/T 20492.Other steel strands shall meet the requirements of GB/T 5224.Stainless steel strands shall meet the requirements of GB/T 25821 and JG/T 200. 6.4.4 In addition to the requirements of 6.4.3 of this Standard and GB/T 11944, the laminated insulating glass for glass skylight system shall also meet the following requirements. 6.4.6 The glass for photovoltaic glass skylight system shall meet the requirements of JGJ 113. 6.5 Hardware 6.5.1 The hardware for glass skylight system shall comply with the relevant national standards. See Annex A for common material standards. 6.5.2 In addition to stainless steel, hardware for glass skylight system shall be anti-corrosive. 6.5.3 The bearing capacity and service life of the hardware shall meet the design requirements. Check the bearing capacity of main stressed hardware. 6.6 Sealing material 6.9 Other materials 6.9.1 Padding material for the top joints of glass skylight system shall use polyethylene foam stick. The density shall not be greater than 37kg/m3. 6.9.2 Graduation of combustion performance of insulation materials for glass skylight system shall comply with relevant requirements of GB 8624.Non- combustible or flame-retardant materials such as rock wool, mineral wool, glass wool shall be used. 7 Production and assembly requirements 7.1 Glass production requirements 7.1.1 The size and allowable deviation of rectangular tempered glass shall meet the requirements of Table 2. feeler 7.1.3 The size and allowable deviation of rectangular insulating glass panels shall meet the requirements of Table 4. 7.1.4 The size and allowable deviation of triangle, rhombus, parallelogram, trapezoid, round panels shall meet the requirements of Table 5. 7.3.1.3 Components shall meet design requirements. The allowable deviation of component assembly shall meet the requirements of Table 12. 7.3.2 Cable rod structure The appearance of the steel cable shall meet the design requirements, without rust spots on the surface. Steel strands shall not have broken wires or other obvious mechanical damage. The stainless-steel strands for cable structure shall meet the relevant requirements of GB/T 25821 and JG/T 200.The allowable deviation of the processing of cable components shall meet the requirements of Table 13. 8 Requirements 8.1 Structural performance 8.1.1 Structural performance of glass skylight system shall include possible wind load, stagnant load, snow load, ice load, sunshade device and lighting device loads, live loads and other loads. Combine the various loads and effects on the glass skylight system in a direction perpendicular to the glass skylight system according to GB 50009 and GB 50011.Take the combined load standard value under the most unfavorable conditions as the performance indicator of the glass skylight system. 8.6 Photothermal performance The photothermal performance of glass skylight system is expressed by light- to-heat ratio (r or LSG). The graduation shall meet the requirements of Table 23. 8.7 Thermal cycling performance 8.7.1 There shall be no condensation on the test piece during the thermal cycling test, without dysfunction or damage. 8.7.2 The thermal cycling performance of glass skylight system shall meet the following requirements. 9 Test methods 9.1 Structural performance The structural performance testing of glass skylight system shall be performed in accordance with GB/T 34555. 9.4 Insulation performance The insulation performance testing of glass skylight system shall be performed in accordance with GB/T 29043.When testing, the test piece shall be installed at the actual angle. The insulation performance can also be calculated according to the method specified by JGJ/T 151. 9.6 Photothermal performance 9.6.1 The measurement of visible light transmittance shall be performed in accordance with GB/T 2680.Visible light transmittance of glass skylight system can be calculated according to JGJ/T 151. 9.7 Thermal cycling performance Thermal cycling performance of glass skylight system can be implemented according to JG/T 397.When testing, the test piece shall be installed at the actual angle. JG/T 231-2018 CONSTRUCTION INDUSTRY INDUSTRIAL STANDARD ICS 91.060.20 P 32 Replacing JG/T 231-2007 Technical requirements of building glass skylight system Issued on. JUNE 26, 2018 Implemented on. DECEMBER 01, 2018 Issued by. Ministry of Housing and Urban-Rural Development of the People's Republic of China

Table of Contents

Foreword... 3 1 Scope... 5 2 Normative references... 5 3 Terms and definitions... 8 Annex A (informative) Detection limit of different matrix specimens... 33 Annex B (informative) Chromatogram of organochlorine pesticide mixed standard solution... 33 Annex C (informative) Method uncertainty... 36 Bibliography... Error! Bookmark not defined.

1 Scope

This Standard specifies the terms and definitions, classification and marks, general requirements, materials and components, production and assembly requirements, requirements and test methods. This Standard is applicable to building glass skylight system.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2680, Determination of light transmittance, solar direct transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors GB/T 4171, Atmospheric corrosion resisting structural steel GB/T 5117, Covered electrodes for manual metal arc welding of non-alloy and fine grain steels GB/T 5118, Covered electrodes for manual metal arc welding of creep- resisting steels GB/T 5224, Steel strand for prestressed concrete GB/T 5237 (all parts), Wrought aluminium alloy extruded profiles for architecture GB/T 8485, The graduation and test for airborne sound insulating properties of windows and doors GB 8624, Classification for burning behavior of building materials and products

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. 3.1 building glass skylight system glass skylight system for short 4 Classification and marks 4.1 Classification 4.1.1 According to the supporting structure, it can be divided into steel structure (G), cable rod structure (S), aluminum alloy structure (L), glass beam structure (B). 4.2 Marks 4.2.1 Marking method The mark is composed of the product code of the glass skylight system (CGD), standard code, support structure category code, opening-closing category code, closed category code, and main parameters (structural performance). 4.2.2 Marking example Example. CGD-S-K-FB/3.5-JG/T231, which represents a closed glass skylight system that is supported by cable rod structure, is openable, the structural performance is 3.5kPa and complies with the industrial standard JG/T 231. 5 General requirements 5.1 The materials used for glass skylight system shall meet the relevant regulations of the current national standards, see Annex A. There shall be exit- factory certificate and quality certificate. 5.3 The area of glass panel used for glass skylight system shall not exceed 2.5m2.The length of the long side shall not be greater than 2m. 5.7 The energy-saving design of glass skylight system shall comply with the requirements of GB 50176, GB 50189, JGJ 26, JGJ 75 and JGJ 134. 5.8 The durability of glass skylight system, anti-condensation (frost, ice) and hail resistance shall meet the design requirements. 5.15 The visible light transmittance of glass skylight system shall meet the lighting design requirements. A glass panel with visible light reflectance not greater than 0.30 is preferred. 6 Materials and components 6.1 Aluminum alloy profile 6.1.1 The base material of aluminum alloy profile shall meet the requirements of GB/T 5237.1.The allowable size deviation shall meet the requirements of high precision or ultra-high precision. 6.1.2 When aluminum alloy profiles using anodizing, electrophoretic painting, powder spraying, fluorocarbon paint spraying for surface treatment, it shall respectively comply with the requirements of GB/T 5237.2, GB/T 5237.3, GB/T 5237.4, and GB/T 5237.5.The thickness of the surface treatment layer shall meet the requirements of Table 1. 6.3 Pull rod 6.3.1 Steel ropes for glass skylight system shall use steel strands. The nominal diameter of the steel strand of the main load steel rope shall not be less than 12mm and shall meet the design requirements. 6.3.2 Zinc-5% aluminum-mixed rare earth alloy coated steel strands shall meet the requirements of GB/T 20492.Other steel strands shall meet the requirements of GB/T 5224.Stainless steel strands shall meet the requirements of GB/T 25821 and JG/T 200. 6.4.4 In addition to the requirements of 6.4.3 of this Standard and GB/T 11944, the laminated insulating glass for glass skylight system shall also meet the following requirements. 6.4.6 The glass for photovoltaic glass skylight system shall meet the requirements of JGJ 113. 6.5 Hardware 6.5.1 The hardware for glass skylight system shall comply with the relevant national standards. See Annex A for common material standards. 6.5.2 In addition to stainless steel, hardware for glass skylight system shall be anti-corrosive. 6.5.3 The bearing capacity and service life of the hardware shall meet the design requirements. Check the bearing capacity of main stressed hardware. 6.6 Sealing material 6.9 Other materials 6.9.1 Padding material for the top joints of glass skylight system shall use polyethylene foam stick. The density shall not be greater than 37kg/m3. 6.9.2 Graduation of combustion performance of insulation materials for glass skylight system shall comply with relevant requirements of GB 8624.Non- combustible or flame-retardant materials such as rock wool, mineral wool, glass wool shall be used. 7 Production and assembly requirements 7.1 Glass production requirements 7.1.1 The size and allowable deviation of rectangular tempered glass shall meet the requirements of Table 2. feeler 7.1.3 The size and allowable deviation of rectangular insulating glass panels shall meet the requirements of Table 4. 7.1.4 The size and allowable deviation of triangle, rhombus, parallelogram, trapezoid, round panels shall meet the requirements of Table 5. 7.3.1.3 Components shall meet design requirements. The allowable deviation of component assembly shall meet the requirements of Table 12. 7.3.2 Cable rod structure The appearance of the steel cable shall meet the design requirements, without rust spots on the surface. Steel strands shall not have broken wires or other obvious mechanical damage. The stainless-steel strands for cable structure shall meet the relevant requirements of GB/T 25821 and JG/T 200.The allowable deviation of the processing of cable components shall meet the requirements of Table 13. 8 Requirements 8.1 Structural performance 8.1.1 Structural performance of glass skylight system shall include possible wind load, stagnant load, snow load, ice load, sunshade device and lighting device loads, live loads and other loads. Combine the various loads and effects on the glass skylight system in a direction perpendicular to the glass skylight system according to GB 50009 and GB 50011.Take the combined load standard value under the most unfavorable conditions as the performance indicator of the glass skylight system. 8.6 Photothermal performance The photothermal performance of glass skylight system is expressed by light- to-heat ratio (r or LSG). The graduation shall meet the requirements of Table 23. 8.7 Thermal cycling performance 8.7.1 There shall be no condensation on the test piece during the thermal cycling test, without dysfunction or damage. 8.7.2 The thermal cycling performance of glass skylight system shall meet the following requirements. 9 Test methods 9.1 Structural performance The structural performance testing of glass skylight system shall be performed in accordance with GB/T 34555. 9.4 Insulation performance The insulation performance testing of glass skylight system shall be performed in accordance with GB/T 29043.When testing, the test piece shall be installed at the actual angle. The insulation performance can also be calculated according to the method specified by JGJ/T 151. 9.6 Photothermal performance 9.6.1 The measurement of visible light transmittance shall be performed in accordance with GB/T 2680.Visible light transmittance of glass skylight system can be calculated according to JGJ/T 151. 9.7 Thermal cycling performance Thermal cycling performance of glass skylight system can be implemented according to JG/T 397.When testing, the test piece shall be installed at the actual angle. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of JG/T 231-2018 be delivered?

Answer: The full copy PDF of English version of JG/T 231-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JG/T 231-2018_English with my colleagues?

Answer: Yes. The purchased PDF of JG/T 231-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- JG/T 231-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version JG/T 231-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JG/T 231-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of JG/T 231-2018?

A step-by-step guide to download PDF of JG/T 231-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JG/T 231-2018".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9