JB/T 9101-1999 (JB/T 9101-2014 Newer Version) PDF English


Search result: JB/T 9101-1999 (JB/T 9101-2014 Newer Version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
JB/T 9101-2014English369 Add to Cart 3 days Fan rotor balance Valid
JB/T 9101-1999English70 Add to Cart 0-9 seconds. Auto-delivery. Fan rotor balance Obsolete
BUY with any currencies (Euro, JPY, GBP, KRW etc.): JB/T 9101-2014     Newer version: JB/T 9101-2014

PDF Preview: JB/T 9101-1999


JB/T 9101-1999: PDF in English (JBT 9101-1999)

JB/T 9101-1999 JB ICS 21. 120. 40 J 72 INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing ZB J72 042-90 Fan Rotor Balance ISSUED ON . JULY 12, 1999 IMPLEMENTED ON. JANUARY 1, 2000 Issued by. State Bureau of Machine Industry Table of Contents Foreword ... 3 1 Scope... 4 2 Normative references ... 4 3 Terms and symbols ... 4 4 Rotor type ... 4 5 Rotor balancing method ... 4 6 Precision of balance equipment and process equipment ... 8 7 Calibration method and requirement ... 8 8 Expression method of balance quality grades ... 9 9 Determination of allowable imbalance amount ... 10 10 Inspection and verification of balance quality ... 12 11 Note of balance requirements in design diagram ... 16 Appendix A ... 17 Foreword This standard references to and adopts ISO 1940-1.1986 "Mechanical Vibration - Balance Quality Requirements for Rigid Rotor - Part 1. Determination of the Allowable Residual Unbalance". This standard is the revision of ZB J72 042-90 "Fan Rotor Balance". It only makes some editorial changes to the previous standard. This standard replaces ZB J72 042-90 from the implementation date. Appendix A is informative. This standard was proposed by and shall be under the jurisdiction of National Fan Standardization Technical Committee. Responsible drafting organization of this standard. Shenyang Fan Factory Co., Ltd. Chief drafting staffs of this standard. Lin Xuemin, Chen Liangming, and Jiang Jilin. Fan Rotor Balance 1 Scope This standard specifies the balance method, grade of balance quality, precision requirements of the balancing equipment, calibration method, and verification of the fan rotor. This standard is applicable to the balance of the rotor or impeller of the centrifugal fan and axial fan. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision. The parties who enter into agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. GB/T 1184-1996 "No Marking Tolerance Value of Shape and Position Tolerance" GB/T 4201-1984 "Method of Verification for Universal Horizontal Balancing Machines" GB/T 6444-1995 "Mechanical Vibration - Balancing Vocabulary" 3 Terms and symbols The relevant terms and symbols which are involved in this standard shall meet the requirements of GB/T 6444. 4 Rotor type According to the structure, fan rotors are classified into 8 types, see Figure 1. 5 Rotor balancing method Generally, fan rotor belongs to rigid rotor. Its balance methods are classified into single-plane (static) balancing and double-plane (dynamic) balancing. 5.1 Single-plane (Static) Balancing 5.1.1 Single-plane (static) balancing is a kind of balance method that based on the unbalanced force of the rotator which is approximately located in the plane where the mass center of the rotator is located at. It is the method to use a calibration plane to perform the balancing, through the swing in the gravitational field. 5.1.2 If the single-plane (static) balancing condition is adopted, the following requirements shall be met. a) If the maximum working speed n is lower than 1500 r/min, and the RATIO of the width 1) This machine number does not belong to the R40 series. According the operating requirements, it shall be kept temporarily. 6 Precision of balance equipment and process equipment 6.1 Select corresponding balance equipment according to the mass of the balance work piece and its balance quality grade. 6.2 The balance equipment must be measured regularly according to the requirements of GB/T 4201. And its precision shall be equal to or higher than the requirement of the balance quality. 6.3 The balance shaft itself shall be equipped with adequate rigidity. Its mass shall be minimized. And it shall be double-plane (dynamic) balanced. Its balance quality grade is 2.5mm/s. 6.4 The coordination between the balance shaft and impeller must not have gaps. The coaxial tolerance BETWEEN the balance supporting surface or axial diameter on the driving end of the balance shaft AND the work piece coordination parts shall not be more than 0.02mm. The balance supporting surface shall be hardening. Its hardness is not less than 40 HRC. The roughness Ra of the supporting surface is not more than 1.60μm. The cylindrical tolerance shall not be less than the grade 6 tolerance specified in GB/T 1184. 6.5 If the rotor is single-bond structure, half-bond (half mass of the bond. That is, remain the bond’s length and width unchanged, the height is halved) shall be equipped in the corresponding bond groove for the balance compensation. 7 Calibration method and requirement 7.1 The material quality of the welded-structure impeller calibration mass (counter weight) shall be identical to that of the welded parental material. Its thickness shall not be more than the thickness of the welded parental material. Use the same method of welding impeller to full- weld it on the lateral surface of the impeller disk (cover). The surrounding of the calibration mass (counter weight) shall be chamfering. The contour shall be clean and neat. The welding seams must not have crack. The quantity and position of the calibration mass (counter weight) are same as the requirements of 7.5. 7.2 The calibration mass (counter weight) of riveted structure impeller is typically fixed to the lateral surface of the impeller disc (cover) by adopting riveting method. The rivet’s quality, diameter and quantity (quantity shall not be less than 2, and it shall have a certain interval distance) shall be determined by strength calculation. The quantity, shape and position of the calibration mass (counter weight) are same as the requirements of 7.1 and 7.5. 7.3 When the calibration mass (counter weight) of the cast structural impeller and band pulley id fixed onto the steel plate with screws, the screw’s quality, diameter and quantity (quantity shall not be less than 2, and it shall have a certain interval distance) shall be determined by strength calculation. Anti-loosing measures must be taken after fastening the screws. The quantity, shape and position of the calibration mass (counter weight) are same as the requirements of 7.1 and 7.5. shown in formula (7). miri=Ui (7) Where. Ui — Residual imbalance amount of a certain calibration plane as shown by the balancing machine, g·mm. ri — Calibration radius on the calibration plane, mm; m i — Calibration mass on the calibration plane, kg. 10 Inspection and verification of balance quality 10.1 The inspection of balance quality is consisted of inspection made in regular production of the manufacturer AND delivery acceptance of the user OR the verification of product sampling to the finished balancing rotors. For the balance made in the regular production of the manufacturer, the residual imbalance amount shall be less than the specified value of the allowable imbalance amount. During the delivery acceptance of the user and the verification or product sampling, the residual imbalance amount is allowed to be more than the specified value of the allowable imbalance amount. The limit value of the two inspections shall comply with those specified in Table 3. Table 3 Balance quality grade G mm/s Regular production inspection limit Limit value of delivery acceptance or verification of product sampling 2.5 ≤90% of the specified value ≤115% of the specified value 4.0 5.6 6.3 10.2 The verification of double-plane (dynamic) balance components on the soft supporting dynamic balancer may adopt the following 2 methods. 10.2.1 Weighting method verification Fix the calibration mass (counter weight) to the rotor. According to the test meter reading and phase of the residual imbalance amount on the 2 calibration planes displayed by the balancing machine meter, add a test mass (test weight) on the weight-bias phase of calibration planes respectively, so as to make it equal to the allowable imbalance amount on that calibration plane. Then, turn on the balancing machine to observe the instrument's reading. If the new reading is more than 1 time of the reading before adding the test mass (test weight), it is deemed that the balance is qualified under general precision requirements. 10.2.2 Curve chart method verification When the calibration mass (counter weight) has been fixed to the rotor, and the test meter reading and phase of the residual imbalance amount on the 2 calibration planes displayed by the balancer meter are known, then add a test mass (it is about 2~... ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.