HG/T 4752-2014 PDF English
US$220.00 · In stock · Download in 9 secondsHG/T 4752-2014: Vinyl ester resin concrete electrolytic cell made by monolithic casting Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
HG/T 4752-2014 | English | 220 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Vinyl ester resin concrete electrolytic cell made by monolithic casting
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: HG/T 4752-2014
HG/T 4752-2014: Vinyl ester resin concrete electrolytic cell made by monolithic casting---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/HGT4752-2014
HG
CHEMICAL INDUSTRY STANDARD OF
THE PEOPLE’S REPUBLIC OF CHINA
ICS 71.120.99
G 94
Filing No.. 48611-2015
Vinyl ester resin concrete electrolytic cell made by
monolithic casting
Issued on: DECEMBER 31, 2014
Implemented on: JUNE 01, 2015
Issued by. Ministry of Industry and Information Technology of PRC
Table of Contents
Foreword... 3
1 Scope... 4
2 Normative references... 4
3 Terms and definitions... 4
4 Product marking... 5
5 Requirements... 5
6 Test method... 7
7 Inspection rules... 8
8 Marking, transportation and storage... 9
Appendix A (Informative) Dimensional stability test method... 11
Vinyl ester resin concrete electrolytic cell made by
monolithic casting
1 Scope
This standard specifies the product marking, requirements, test methods, inspection
rules, marking, transportation and storage of vinyl ester resin concrete electrolytic cell
made by monolithic casting (commonly known as vinyl resin in the industry).
This standard applies to vinyl ester resin concrete electrolytic cell made by monolithic
casting for the purpose of non-ferrous metal hydrometallurgy, with acid-resistant quartz
sand as reinforcing aggregate and vinyl ester resin as binder, as well as vinyl ester resin
electrolytic cells with similar different use environments.
2 Normative references
The following documents are essential to the application of this document. For the dated
documents, only the versions with the dates indicated are applicable to this document;
for the undated documents, only the latest version (including all the amendments) is
applicable to this standard.
GB/T 1410 Methods of test for volume resistivity and surface resistivity of solid
electrical insulating materials
GB 50212 Specification for construction and acceptance of anticorrosive
engineering of buildings
DL/T 5150 Test code for hydraulic concrete
JGJ 51 Technical specification for lightweight aggregate concrete
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Vinyl ester resin concrete
A concrete material made of vinyl ester resin as a binder, acid-resistant quartz sand
as a reinforcing aggregate, by adding initiator and accelerator.
the test result.
6.10 Full water test
Fix the support seat on the test platform according to the actual support working
condition of the electrolytic cell; place the electrolytic cell in position. Plug the drain
port; fill the cell with water (normal temperature) to the overflow port position; keep it
for 24 hours. U-shaped clamps and other protective devices can be set on the electrolytic
cell, to prevent the cell from deforming; the platform and support seat shall have
sufficient strength and rigidity.
6.11 Dimension stability test
The dimensional stability of the electrolytic cell is tested by load temperature simulation
test. The test load is 1.2 times the actual working condition of the electrolytic cell; the
test water temperature shall be 10 °C higher than the actual working condition
temperature of the electrolytic cell. For the recommended test method, refer to
Appendix A.
7 Inspection rules
7.1 Inspection items
7.1.1 Exit-factory inspection
The exit-factory inspection items are the appearance inspection, dimensional tolerance
inspection, and full water test specified in Table 2 of Chapter 5.
7.1.2 Type inspection
The type inspection items are the contents specified in 5.2 and 5.3.
Type inspection shall be carried out in any of the following situations.
a) Before the product is successfully manufactured for the first time and put into
normal production;
b) Where there are major changes in materials and processes that may affect product
performance;
c) When production is resumed after one year of suspension;
d) When normal production reaches 3 years;
e) When the national quality supervision department proposes a type inspection
requirement.
7.2 Sampling rules
7.2.1 Exit-factory inspection sampling
During exit-factory inspection, the product shall be 100% inspected by the quality
inspection department of the manufacturer.
7.2.2 Type inspection sampling
When conducting type inspection of vinyl ester resin concrete material performance,
the vinyl ester resin concrete material shall be randomly selected during the casting
process of the electrolytic cell; no additional preparation is allowed. The test pieces to
be tested shall be 3 groups; the number of test pieces in each group shall comply with
the relevant inspection standards. One group is used for the initial inspection. If it fails,
the other two groups are used for double sampling and re-inspection.
When conducting type inspection of vinyl ester resin concrete electrolytic cell products
made by monolithic casting, a batch of electrolytic cell products shall be randomly
selected for inspection; then 3 units from the batch shall be randomly selected as
samples, one for the initial inspection, if it fails, the other two for double sampling and
re-inspection. 100 electrolytic cell products produced continuously with the same raw
materials and the same production process are regarded as a batch; if it is less than 100
units, they are counted as a batch.
7.3 Judgment rules
7.3.1 Exit-factory inspection judgment
During exit-factory inspection, if all three inspection items of appearance inspection,
external dimension tolerance inspection, full water test are qualified, it is judged as
qualified products; otherwise, it is unqualified products.
7.3.2 Type inspection judgment
During type inspection, if all inspection items are qualified, the batch is judged as
qualified products; if there are unqualified items in the inspection items, the unqualified
items will continue to be doubled for re-inspection. If they are still unqualified, the
batch is judged as unqualified products.
Disposal of unqualified products. If one of the appearance inspection and full water test
fails, it will be treated as waste.
8 Marking, transportation and storage
8.1 Marking
Each product shall be marked with product model, product number, production date,
Appendix A
(Informative)
Dimensional stability test method
A.1 Instruments and equipment
Instruments and equipment include dial indicator (division value 0.01 mm) or
displacement sensor, thermometer or thermocouple (accuracy not greater than 1 °C),
electric heater, test platform, dial indicator bracket.
A.2 Test conditions
The test load is 1.2 times the actual working condition; the test water temperature shall
be 10 °C higher than the normal working temperature of the electrolytic cell.
A.3 Distribution of measurement points
Since the structure of the electrolytic cell is basically symmetrical and the load it bears
is evenly and symmetrically distributed, it is approximately assumed that the
deformation of the electrolytic cell is also symmetrical; 20 detection points are selected
to be arranged within the range of one-half of the side wall of the cell and one-half of
the bottom plate. If the electrolytic cell is an asymmetric structure with an inclined
bottom, the arrangement range of the 20 detection points is selected on the side wall
and bottom plate of the cell at one end of the short support leg.
Distribution of measurement points on the long side wall. On the vertical dividing lines
that divide the length of the 3 side walls into six equal parts, 3 measurement points are
arranged at 2 points on each dividing line that divides it into three equal parts and 1
point on the upper edge of the cell, for a total of 9 measurement points.
Distribution of measurement points on the short side wall. 3 measurement points are
arranged at 2 points on the vertical center line of the short side wall that divides it into
two equal parts and 1 point on the upper edge of the cell.
Distribution of bottom plate measurement points. 3 measurement points are arranged at
3 points on the four-quarters of the bottom plate's horizontal centerline.
Distribution of overall displacement measurement points of the electrolytic cell. 2
relative measurement points are arranged on the two long side walls near the support
seat and 20 mm away from the bottom plate; 2 relative measurement points are arranged
on the two short side walls near the bottom corner of the cell and 20 mm away from the
bottom plate; 1 measurement point is arranged on the bottom plate 20 mm away from
the support seat, for a total of 5 measurement points.
The distribution positions of the measurement points on the long side wall, short side
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of HG/T 4752-2014 be delivered?Answer: The full copy PDF of English version of HG/T 4752-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of HG/T 4752-2014_English with my colleagues?Answer: Yes. The purchased PDF of HG/T 4752-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- HG/T 4752-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of HG/T 4752-2014?A step-by-step guide to download PDF of HG/T 4752-2014_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "HG/T 4752-2014". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|