HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (22 Mar 2025)

GB/T 4830-2015 PDF English (GB/T 4830-1984: Older version)


Search result: GB/T 4830-2015 (GB/T 4830-1984 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 4830-2015English105 Add to Cart 0-9 seconds. Auto-delivery. Industrial process measurement and control instruments -- Pressure range and quality of air supply Valid
GB/T 4830-1984English199 Add to Cart 3 days Pressure range and quality of air supply for the industrial process measurement and control instruments Obsolete


PDF Preview: GB/T 4830-2015


GB/T 4830-2015: PDF in English (GBT 4830-2015)

GB/T 4830-2015 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 25.040.40 N 10 Replacing GB/T 4830-1984 Industrial Process Measurement and Control Instruments – Pressure Range and Quality of Air Supply ISSUED ON. DECEMBER 10, 2015 IMPLEMENTED ON. JULY 1, 2016 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. Table of Contents Foreword ... 3 1 Scope ... 4 2 Terms and Definitions ... 4 3 Pressure Range ... 4 4 Quality ... 5 Appendix A (Informative) Test on Quality of Air Supply ... 6 Appendix B (Informative) Relevant Formula and Chart ... 8 Foreword This Standard was drafted as per the rules specified in GB/T 1.1-2009. This Standard replaced GB/T 4830-1984 Pressure Range and Quality of Air Supply for the Industrial Process Measurement and Control Instruments. Compared with GB/T 4830-1984, this Standard has the following major technical changes besides the editorial modification. --- Add “1 Scope”, the clause numbers thereafter shall be postponed (see Chapter 1); --- Delete non-international units (see 3.1, 3.2.1, 4.4, Figure B.1 of this Edition; 2.1, 2.2.1, 3.3 Figure B.1 of 1984 Edition); --- Add “4.1 Overview”, the clause numbers thereafter shall be postponed (see 4.1 of this Edition; Chapter 3 of 1984 Edition); --- Add A.2 title “Requirements for test equipment” (see A.2 of this Edition; A.2 of 1984 Edition); --- Replace “mmHg” by “kPa”, corresponding values are also converted (see B.1.1, B.2 of this Edition; B.1.1, B.2 of 1984 Edition); --- Replace “mmHg” and “kg/cm2” by “MPa”, the corresponding values are also converted (see Figure B.1of this Edition; Figure B.1 of 1984 Edition). This Standard was proposed by China Machinery Industry Federation. This Standard shall be under the jurisdiction of National Technical Committee for Standardization of Industrial Process Measurement and Control (SAC/TC 124). Drafting organizations of this Standard. Southwest University, Shenzhen Libiao Technology Development Co., Ltd., Zhenzhou City Municipal Engineering Design & Research Institute, and China Silian Instrument Group Co., Ltd. Chief drafting staffs of this Standard. Zhou Xuelian, Chen Ru, Duan Jingkui, Liu Jin, He Qiang, Li Tao, Huang Renjie, and Yang Songhua. The historical edition replaced by this Standard is as follows. --- GB/T 4830-1984. Industrial Process Measurement and Control Instruments – Pressure Range and Quality of Air Supply 1 Scope This Standard specifies the requirements for pressure range and quality of air supply for industrial process measurement and control instruments. This Standard is applicable to the air supply used by the industrial process measurement and control instruments. 2 Terms and Definitions The following terms and definitions are applicable to this document. 2.1 On line pressure The gas pressure delivered from the purifying device outlet to the instrument input end pipe network. 2.2 Ambient temperature limit The minimum temperature on the site where there is a whole system including the purifying device outlet, pipe network and instrument. 3 Pressure Range 3.1 Pressure range of air supply on the purifying device outlet The pressure range of air supply on the purifying device outlet is 300kPa~500kPa; and 500kPa~800kPa. 3.2 Pressure range of air supply on the instrument input end 3.2.1 The nominal pressure value of air supply on the instrument input end is 140kPa, 260kPa, 350kPa, 550kPa and 700kPa. 3.2.2 The allowable pressure fluctuation range of air supply on the instrument input Appendix A (Informative) Test on Quality of Air Supply A.1 Test objective Check and supervise whether the quality of air supply meets the requirements of this Standard; so provide basis timely for detecting and eliminating the failure of air supply system. A.2 Requirements for test equipment All instruments and equipment used in the test shall be verified and calibrated according to the provisions or requirements of relevant departments. A.3 Test Items A.3.1 Dew point. A.3.2 Dust-contained particle size. A.3.3 Oil content A.4 Test methods A.4.1 Test method on dew point Measure by trace water analyzer with accuracy no less than ±10% (volume ratio ppm); the obtained data shall be converted as per relevant formula (curve or table). A.4.2 Test method on dust-contained particle size Adopt the light scattering principle counting method. A.4.3 Test method on oil content Sampling mode. CCl4 (carbon tetrachloride) absorption method. Analyzing method. spectrophotometry. The simple chart of test system can refer to Figure A.1. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.